Description
The DataSet contains the results of the mechanical behaviour of a concrete cube with dimensions 70 x 70 x 70 cm3under the splitting test. Three cubes were tested: cube 1 (concrete with polymer fibres), cube 2 (concrete with steel fibres) and cube 3 (plain concrete).
Before and after splitting, wave propagation signals were registered with a sampling frequency of 20 MHz. The excitation was a one-cycle wave packet with a central frequency of 100 kHz. The configuration of transmitters (T1-T12) and receivers (R1-R12) is shown in the figure.
The files utilize a comma-separated values (.csv) format and contain wave propagation signals of a length of 5 m. In a single file, the time vector (in ms) and the signals from channels A, B, C, D, E, F and G (in V) can be found.
Dataset file
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
where a single part of the file is 512 MB in size.Example script for calculation:
https://github.com/antespi/s3md5
File details
- License:
-
open in new tabCC BYAttribution
- Raw data:
- Data contained in dataset was not processed.
Details
- Year of publication:
- 2022
- Verification date:
- 2022-06-21
- Dataset language:
- English
- Fields of science:
-
- Civil engineering and transport (Engineering and Technology)
- mechanical engineering (Engineering and Technology)
- DOI:
- DOI ID 10.34808/p2fs-5z67 open in new tab
- Funding:
- Verified by:
- Gdańsk University of Technology