Effect of Maximal Apnoea Easy-Going and Struggle Phases on Subarachnoid Width and Pial Artery Pulsation in Elite Breath-Hold Divers
Abstract
Purpose: The aim of the study was to assess changes in subarachnoid space width (sas-TQ), the marker of intracranial pressure (ICP), pial artery pulsation (cc-TQ) and cardiac contribution to blood pressure (BP), cerebral blood flow velocity (CBFV) and cc-TQ oscillations throughout the maximal breath hold in elite apnoea divers. Non-invasive assessment of sas-TQ and cc-TQ became possible due to recently developed method based on infrared radiation, called near-infrared transillumination/backscattering sounding (NIR-T/BSS). Methods: The experimental group consisted of seven breath-hold divers (six men). During testing, each participant performed a single maximal end-inspiratory breath hold. Apnoea consisted of the easy-going and struggle phases (characterised by involuntary breathing movements (IBMs)). Heart rate (HR) was determined using a standard ECG. BP was assessed using the photoplethysmography method. SaO2 was monitored continuously with pulse oximetry. A pneumatic chest belt was used to register thoracic and abdominal movements. Cerebral blood flow velocity (CBFV) was estimated by a 2-MHz transcranial Doppler ultrasonic probe. sas-TQ and cc-TQ were measured using NIR-T/BSS. Wavelet transform analysis was performed to assess cardiac contribution to BP, CBFV and cc-TQ oscillations. Results: Mean BP and CBFV increased compared to baseline at the end of the easy phase and were further augmented by IBMs. cc-TQ increased compared to baseline at the end of the easy phase and remained stable during the IBMs. HR did not change significantly throughout the apnoea, although a trend toward a decrease during the easy phase and recovery during the IBMs was visible. Amplitudes of BP, CBFV and cc-TQ were augmented. sas-TQ and SaO2 decreased at the easy phase of apnoea and further decreased during the IBMs. Conclusions: Apnoea increases intracranial pressure and pial artery pulsation. Pial artery pulsation seems to be stabilised by the IBMs. Cardiac contribution to BP, CBFV and cc-TQ oscillations does not change throughout the apnoea.
Citations
-
1 3
CrossRef
-
0
Web of Science
-
1 4
Scopus
Authors (10)
Cite as
Full text
- Publication version
- Accepted or Published Version
- DOI:
- Digital Object Identifier (open in new tab) 10.1371/journal.pone.0135429
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuł w czasopiśmie wyróżnionym w JCR
- Published in:
-
PLOS ONE
no. 10,
edition 8,
pages 1 - 13,
ISSN: 1932-6203 - Language:
- English
- Publication year:
- 2015
- Bibliographic description:
- Winklewski P., Barak O., Madden D., Gruszecka A., Gruszecki M., Gumiński W., Kot J., Frydrychowski A., Drvis I., Dujic Z.: Effect of Maximal Apnoea Easy-Going and Struggle Phases on Subarachnoid Width and Pial Artery Pulsation in Elite Breath-Hold Divers// PLOS ONE. -Vol. 10, iss. 8 (2015), s.1-13
- DOI:
- Digital Object Identifier (open in new tab) 10.1371/journal.pone.0135429
- Verified by:
- Gdańsk University of Technology
seen 126 times
Recommended for you
Pial artery and subarachnoid width response to apnoea in normal humans
- M. Wszędybył-Winklewska,
- J. Wolf,
- E. Świerblewska
- + 8 authors
Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency
- P. J. Winklewski,
- M. Gruszecki,
- J. Wolf
- + 9 authors
Effects of consecutive apneas on pial artery pulsation and subarachnoid width in healthy subjects
- M. Wszędybył-Winklewska,
- J. Wolf,
- E. Świerblewska
- + 7 authors