Abstract
The paper presents a metrological analysis of the measurement system used for diagnosis of induction motor bearings, based on the analysis of the instantaneous power. This system was implemented as a set of devices with dedicated software installed on a PC. A number of measurements for uncertainty estimation was carried out. The results of the measurements are presented in the paper. The results of the aforementioned analysis helped to determine the measurement uncertainty which can be expected during bearing diagnostic measurements, by the method relied on measurement and analysis of the instantaneous power of an induction machine.
Citations
-
1 0
CrossRef
-
0
Web of Science
-
1 6
Scopus
Authors (2)
Cite as
Full text
- Publication version
- Accepted or Published Version
- DOI:
- Digital Object Identifier (open in new tab) 10.2478/v10178-012-0050-7
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuł w czasopiśmie wyróżnionym w JCR
- Published in:
-
Metrology and Measurement Systems
no. XIX,
pages 573 - 582,
ISSN: 0860-8229 - Language:
- English
- Publication year:
- 2012
- Bibliographic description:
- Dzwonkowski A., Swędrowski L.: Uncertainty analysis of measuring system for instantaneous power research// Metrology and Measurement Systems. -Vol. XIX, nr. no. 3 (2012), s.573-582
- DOI:
- Digital Object Identifier (open in new tab) 10.2478/v10178-012-0050-7
- Verified by:
- Gdańsk University of Technology
seen 123 times