Abstract
This article describes an evaluation of mini heat exchangers operation as a decentralized mechanical ventilation system with recuperative heat recovery that can be integrated into the window frame. The relatively small yet efficient air recuperation system allows for retrofitting existing buildings by reducing the overall energy consumption and thus the CO2 emissions. The proposed design, unlike existing systems, is easy to scale up to various room sizes and is a promising solution for buildings where a centralized recuperation system cannot be implemented or interfering with the building’s facade is not allowed. The experimental research was carried out enabling to collect temperature, pressure drop, and volumetric flow rate measurements in a recuperation system with various minigeometries, namely minichannels with a hydraulic diameter of 3.00 mm, minigaps with a hydraulic diameter of 5.82 mm, and minigaps with a hydraulic diameter of 1.98 mm. The system was tested for a room air temperature of 22°C and three values of outside air temperatures, namely 5°C, 10°C, and 15°C. The volumetric flow rate for a single heat exchanger ranged from 4.1 m3/h to 20.4 m3/h. The results showed that higher temperature rise of supplied air and higher energy efficiency of the heat recovery can be achieved for smaller airflows and higher differences between outside and room temperatures. For an exemplary 34 m2 office room, the 0.8-fold air exchange rate can be provided and 1 667.1 kWh of annual energy savings can be achieved, corresponding to 50.3% of total energy required for heating the air. Heat exchangers equipped with 3.00 mm minichannels recover a similar amount of heat as the ones equipped with 5.82 mm minigaps, even though the hydraulic diameter of the minichannel is almost 2 times smaller. Meanwhile, a 5.82 mm minigap reduces the pressure drop by 76% compared to a 3.00 mm minichannel.
Citations
-
1
CrossRef
-
0
Web of Science
-
1
Scopus
Authors (4)
Cite as
Full text
full text is not available in portal
Keywords
Details
- Category:
- Articles
- Type:
- artykuły w czasopismach
- Published in:
-
APPLIED THERMAL ENGINEERING
no. 247,
ISSN: 1359-4311 - Language:
- English
- Publication year:
- 2024
- Bibliographic description:
- Dąbrowski P., Andrzejczyk R., Wacławik M., Mikielewicz D.: Window frame integrable air recuperation minichannel/minigap heat exchanger// APPLIED THERMAL ENGINEERING -Vol. 247, (2024), s.123116-
- DOI:
- Digital Object Identifier (open in new tab) 10.1016/j.applthermaleng.2024.123116
- Sources of funding:
-
- Free publication
- Verified by:
- Gdańsk University of Technology
seen 97 times
Recommended for you
Exergy analysis of the Szewalski cycle with a waste heat recovery system
- T. Kowalczyk,
- P. Ziółkowski,
- J. Badur