PhD Marcin Guzinski
Employment
- 2020 - present Staff Scientist at Eye Institute
- 2019 - 2020 Research Fellow at Eye Institute
- 2013 - 2019 Postdoctoral Fellow at BME
Publications
Filters
total: 22
Catalog Publications
Year 2021
-
Gold-modified paper as microfluidic substrates with reduced biofouling in potentiometric ion sensing
Publication -
Polymeric membrane-modified voltammetric sensors for lipophilic analytes with nanomolar detection limit: Key parameters influencing the response characteristics
Publication
Year 2020
-
Deposition of EDOT-Decorated Hollow Nanocapsules into PEDOT Films for Optical and Electrochemical Sensing
Publication -
Evaluation, Pitfalls and Recommendations for the “Water Layer Test” for Solid Contact Ion‐selective Electrodes
Publication -
Kinetic Description of the Membrane–Solution Interface for Ion-Selective Electrodes
Publication -
Plasticized PVC Membrane Modified Electrodes: Voltammetry of Highly Hydrophobic Compounds
Publication
Year 2019
Year 2018
Year 2017
-
PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
Publication -
Solid-Contact pH Sensor without CO2Interference with a Superhydrophobic PEDOT-C14as Solid Contact: The Ultimate “Water Layer” Test
Publication
Year 2016
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublicationSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Poly(3-octylthiophene) as solid contact for ion-selective electrodes: contradictions and possibilities
Publication
Year 2015
-
Equilibration Time of Solid Contact Ion-Selective Electrodes
Publication -
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublicationThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublicationLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
Year 2014
Year 2013
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
Publication -
Solid-Contact Ion-Selective Electrodes with Highly Selective Thioamide Derivatives of p-tert-Butylcalix[4]arene for the Determination of Lead(II) in Environmental Samples
Publication
Year 2012
-
Calix[4]Arenes Appended with Thioamide Moieties as Powerful Tool for Heavy Metals Recognition
Publication
Year 2011
Year 2009
seen 755 times