Accounting for the distributions of input quantities in the procedure for the measurement uncertainty evaluation when calibrating the goniometer
Abstract
The discords concerning the measurement uncertainty evaluation in the Guide to the Expressing of Uncertainty in Measurement (GUM) and its Supplement 1 are considered. To overcome these discords, the authors of the paper propose to use the kurtosis method and the law of the propagation of the expanded uncertainty. Using the example of the goniometer calibration, the features of accounting for the distribution laws of input quantities in the procedure for the measurement uncertainty evaluation are shown. A model for direct measurements of the value of a reference measure of the angle using a goniometer is written, the procedures for the measurement uncertainty evaluation are described, and uncertainty budgets for each of the methods are given. An example of the measurement uncertainty evaluation when calibrating a digital goniometer using a 24-sided reference prism is described. An estimate of the expanded measurement uncertainty for this example was made based on the web-based software application NIST Uncertainty Machine, which showed a good agreement with the estimates obtained by the considered methods. The technology of applying this software application for the confidence level of 0,9545, which the software lacks, is shown. The estimates of the measurement uncertainty obtained by the proposed methods, Monte Carlo method and methodology of the Guide to the Expressing of Uncertainty in Measurement are compared.
Citations
-
0
CrossRef
-
0
Web of Science
-
0
Scopus
Authors (4)
Cite as
Full text
- Publication version
- Accepted or Published Version
- DOI:
- Digital Object Identifier (open in new tab) 10.24027/2306-7039.1.2023.282586
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuły w czasopismach
- Published in:
-
Ukrainian Metrological Journal
pages 34 - 38,
ISSN: 2306-7039 - Language:
- English
- Publication year:
- 2023
- Bibliographic description:
- Zakharov I., Zadorozhna I., Świsulski D., Diakov D.: Accounting for the distributions of input quantities in the procedure for the measurement uncertainty evaluation when calibrating the goniometer// Ukrainian Metrological Journal -,iss. 1 (2023), s.34-38
- DOI:
- Digital Object Identifier (open in new tab) 10.24027/2306-7039.1.2023.282586
- Sources of funding:
-
- Free publication
- Verified by:
- Gdańsk University of Technology
seen 164 times
Recommended for you
Peculiarities of measurement uncertainty evaluation at calibrating a ring gauge
- I. Zakharov,
- O. Botsiura,
- D. Diakov
- + 1 authors
Uncertainty of the liquid mass flow measurement using the orifice plate
- A. Golijanek-Jędrzejczyk,
- D. Świsulski,
- R. Hanus
- + 2 authors
Estimating the uncertainty of the liquid mass flow using the orifice plate
- A. Golijanek-Jędrzejczyk,
- D. Świsulski,
- R. Hanus
- + 2 authors