Abstract

The paper presents the results of an experimental study of a cylindrical orifice with the orifice diameter ratio β = 0.5 and the flow opening length‑to‑diameter ratio L/d = 1, with hydraulic oil flowing in the DN50 measuring channel. The measurements of the values characterising the oil flow were made in the laminar flow regime, for the Reynolds numbers ranging between Re = 100 to 950. Based on the experimental tests, standard flow characteristics were created for four kinematic viscosity values in the range of 13.4–33.3 cSt, for which the average value of the discharge coefficient C in the tested flow rate range of q v < 0.5 dm 3 /s was determined.

Citations

  • 0

    CrossRef

  • 0

    Web of Science

  • 0

    Scopus

Keywords

Details

Category:
Articles
Type:
artykuły w czasopismach
Published in:
Scientific Reports no. 13,
ISSN: 2045-2322
Language:
English
Publication year:
2023
Bibliographic description:
Golijanek-Jędrzejczyk A., Mrowiec A.: Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5// Scientific Reports -,iss. 13 (2023),