Filters
total: 43
Search results for: ORIFICE
-
Cylindrical orifice testing in laminar flow with the orifice diameter ratio β = 0.5
PublicationThe paper presents the results of an experimental study of a cylindrical orifice with the orifice diameter ratio β = 0.5 and the flow opening length‑to‑diameter ratio L/d = 1, with hydraulic oil flowing in the DN50 measuring channel. The measurements of the values characterising the oil flow were made in the laminar flow regime, for the Reynolds numbers ranging between Re = 100 to 950. Based on the experimental tests, standard...
-
Uncertainty of the liquid mass flow measurement using the orifice plate
PublicationThe article presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. This subject is essential because of the widespread use of this type of flow meters. Not only the quantitative estimation but also the qualitative results of those measurements are important. To achieve these results the authors of the paper propose to use the theory of uncertainty. The article shows the analysis of the...
-
A numerical and experimental analysis of multi-hole orifice in turbulent flow
PublicationIn this research study, the comprehensive metrological analysis is investigated for a 4-hole orifice with module m = 0.25 installed in the pipeline with an internal diameter of 50 mm. A detailed numerical simulation was performed for the turbulence models: k-ε-realizable and k-ω-BSL. The novelties of the research include model validation by comparing the results of numerical studies with the experiment conducted in the area of...
-
The assessment of metrological properties of segmental orifice based on simulations and experiments
PublicationSegmental orifices are often used to measure flows of heterogeneous mixtures, especially in flow meters in the power industry, for example. The orifice (with module m= 0.25) was installed in a stainless-steel pipe with internal diameter of 50 mm, placed in a hydraulic water system. The research was performed for Reynolds numbers ranging from 9,000 to 17,000. The flow characteristics of this orifice obtained based on simulation...
-
Estimating the uncertainty of the liquid mass flow using the orifice plate
PublicationThe article presents estimation of measurement uncertainty of a liquid mass flow using the orifice plate. This subject is essential because of the widespread use of this type of flow meters, which renders not only the quantitative estimation but also qualitative results of this type so those measurements are important. To achieve this goal, the authors of the paper propose to use the theory of uncertainty. The article shows the...
-
The PIV Measurements of Time-Averaged Parameters of the Synthetic Jet for Different Orifice Shapes
Publication -
Determination of the uncertainty of mass flow measurement using the orifice for different values of the Reynolds number
PublicationStandard orifice flowmeters are widely used in the chemical and energy industry. Therefore, it is essential to know how accurate the measurements made with these instruments are. The paper presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. The authors will present the influence of ranges of the Reynolds number on the estimated uncertainty, obtained on the basis of simulation and laboratory...
-
Sharp and Rounded Cutouts in a Chevron Orifice and Them Impact on the Acoustic and Flow Parameters of Synthetic Jet
Publication -
A FEM membrane model of human fascia-synthetic implant system in a case of a stiff ventral hernia orifice
PublicationPraca prezdstawia model matematyczny układu tkanka ludzka - implant syntetyczny w postaci tzw. siatki w leczeniu przepuklin brzusznych. Implant jest tu moelowany jako struktura membranowa. Ocena wpływu danych materiałowych oraz wstępnego napięcia na zachowanie pracującej membrany po implantacji została przedstawiona na podstawie analizy wrażliwości. Pracę podsumowują pewne wskazówki dla chirurgów implantujących siatki.
-
Uncertainty of mass flow measurement using centric and eccentric orifice for Reynolds number in the range 10,000 ≤ Re ≤ 20,000
PublicationThe article analyses the impact of the Reynolds number on the estimated uncertainty of the mass flow rate measurement using an orifice plate. The objects of the research were two types of orifices: centric (ISA) and eccentric, with the diameter ratio β = 0.5. Studies were performed by Monte Carlo simulation and experiments for Reynolds numbers in the range 10,000 ≤ Re ≤ 20,000. The obtained results have shown that for both orifice...
-
Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)
Open Research DataThe data was obtained as part of the project "Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)", in which flow tests of hydraulic oil through a cylindrical orifice with a thickness of l = 25 mm and a throat b = 0.5 (diameter pipes D = 50 mm, orifice diameter d = 25 mm) on the test stand at the Department...
-
Acoustic and Flow Aspects of Synthetic Jet Actuators with Chevron Orifices
Publication -
Synthetic Jet Actuators with the Same Cross-Sectional Area Orifices-Flow and Acoustic Aspects
Publication -
Analysis of the structure of the atomized fuel spray with marine diesel engine injector in the early stage of injection
PublicationThis paper presents the results of the experimental research of the atomized fuel spray with the marine diesel engine injector in the constant volume chamber. The specificity of the phenomena occurring in the marine engine cylinder was the reason to use the optical visualisation method in the studies – the Mie scattering technique. This work presents an analysis of the influence of different geometry of outlet orifice and opening...
-
Assessment of usefulness of different tacks in laparoscopic ventral hernia repair
PublicationLaparoscopic ventral hernia repair is becoming a popular technique with good results and fast postoperative recovery. The mesh is placed directly under the peritoneum and anchored with transabdominal sutures and tacks. However, the ideal size of the mesh covering the hernia orifice is know, nor the ideal type or amount of tacks has to be described.
-
Investigation of abdomen surface deformation due to life excitation: implications for implant selection and orientation in laparoscopic ventral hernia repair
PublicationVentral hernia is a common medical problem. Statistically there are around 10% recurrences of the sickness. The authors' former investigation proved edges of the hernia orifice displacements to be one of the factors causing recurrence. Thus, experimental investigation of the abdomen surface deformation due to some normal activities of people is studied.The extreme strains, their localization and directions are identified. The acquired...
-
Magnetic instrumentation and other applications of magnets in NOTES
PublicationModern surgery is developing towards a minimally invasive approach. To minimize the trauma the number of ports is either limited as in single incision laparoscopic procedures or ports are introduced through natural orifices as in nat- ural orifice translumenal endoscopic surgery (NOTES). To provide surgeons with appropriate instrumentation novel technologies are employed involving magnets. This article summarizes the theoretical...
-
Comparative in vitro research of the Human Aortic Bioprosthesis
PublicationE valuate of the usefulness and reliability of structures based on the analysis of recorded parameters determining the flow through the Human Aortic Bioprosthesis (HAB) have been dealt with. By flow parameters changes determining the performance environment of prosthesis analyzed change of the motion dynamics of the valve leaflets as a function of pressure, thereby determining the degree of alignment of the prosthesis to the performance...
-
Other specified noninflammatory disorders of cervix uteri - Female, 63 - Tissue image [6020730010709451]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified noninflammatory disorders of cervix uteri - Female, 63 - Tissue image [6020730010708801]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified noninflammatory disorders of cervix uteri - Female, 63 - Tissue image [6020730010702441]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified noninflammatory disorders of cervix uteri - Female, 63 - Tissue image [6020730010708491]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
A numerical analysis of the thermal effects in the jet impingement stagnation zone
PublicationMost of the flows occurring in the engineering systems are turbulent and their accurate numerical analysis is still challenging, especially when combined with the heat transfer. One of the methods of heat transfer enhancement is utilization of the turbulent impinging jets, which were recently applied also in the heat exchangers. Their positive impact on the heat transfer performance was proven, but many questions related to its...
-
Uterus, unspecified - Female, 44 - Tissue image [413073001884811]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Problems of Measuring Gas Content in Oil in a Two-Phase Flow: A Review
PublicationIn view of the necessity of measuring the air content in oil in two-phase flows in the context of general industry, a review of the most popular methods of measuring the air content in oil was carried out. This review includes an assessment of their advantages and disadvantages and of whether they meet criteria such as the degree of filling, the size and number of bubbles, verification, the absence of additional pressure drops,...
-
SIMULATION OF PROCEED® SURGICAL MESH APPLIED TO VENTRAL HERNIA REPAIR
PublicationIn the present research, Proceed® implant is considered. The system is subjected to short-time dynamic pressure load, similar to post-operative cough naturally occurring in human abdomen. The model refers to a clinical case of 5cm of hernia operated by Proceed implant fixed by 15 joints every 3cm around the orifice. The simulations of the implanted mesh are performed by means of the Finite Element Method. The implant is modelled...
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [5240730032367291]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [5240730032365601]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [52407300323681]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [524073003236571]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [5240730032379311]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [5240730032362571]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [524073003236541]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [5240730032373661]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [5240730032361921]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [5240730032375381]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [524073003236271]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [5240730032374881]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [5240730032362841]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoma in situ of cervix uteri - Female, 64 - Tissue image [524073003236601]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.
Publicationrepairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of highquality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. Method The authors conducted...
-
Thermal and Hydrodynamic Phenomena in the Stagnation Zone — Impact of the Inlet Turbulence Characteristics on the Numerical Analyses
PublicationOne of the methods of heat transfer enhancement is utilization of the turbulent impinging jets, which were recently applied, for example, in the heat exchangers. Their positive impact on the heat transfer performance was proven, but many questions related to the origin of this impact are still unanswered. In general, the wall-jet interaction and the near-wall turbulence are supposed to be its main reason, but their accurate numerical...
-
Cavitation based cleaner technologies for biodiesel production and processing of hydrocarbon streams: A perspective on key fundamentals, missing process data and economic feasibility – A review
PublicationThe present review emphasizes the role of hydrodynamic cavitation (HC) and acoustic cavitation in clean and green technologies for selected fuels (of hydrocarbon origins such as gasoline, naphtha, diesel, heavy oil, and crude oil) processing applications including biodiesel production. Herein, the role of cavitation reactors, their geometrical parameters, physicochemical properties of liquid media, liquid oxidants, catalyst loading,...