Destructive Consequences of PWM Inverter Feeding for Traction AC Motors - Publication - Bridge of Knowledge

Search

Destructive Consequences of PWM Inverter Feeding for Traction AC Motors

Abstract

The electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the undesirable high frequency bearings currents flow. Presented results of carried out experimental examination exemplify described phenomena in traction AC motors.

Cite as

Full text

full text is not available in portal

Keywords

Details

Category:
Monographic publication
Type:
rozdział, artykuł w książce - dziele zbiorowym /podręczniku w języku o zasięgu międzynarodowym
Title of issue:
Modern Electric Traction : Power Supply strony 151 - 161
Language:
English
Publication year:
2009
Bibliographic description:
Łuszcz J., Dworakowski P.: Destructive Consequences of PWM Inverter Feeding for Traction AC Motors// Modern Electric Traction : Power Supply/ ed. eds. K. Karwowski, A. Szeląg. - University of Technology Faculty of Electrical and Control Engineering. Gdańsk: University of Technology, 2009, s.151-161
Verified by:
Gdańsk University of Technology

seen 122 times

Recommended for you

Meta Tags