Abstract
The elastic stability of axially compressed column related to the cross-section distortion is investigated. Two kinds of closed quadratic cross-sections are taken into consideration with internal walls and without it. The governing differential equation is derived with aid of the principle of stationary total potential energy. The critical loads for the simply supported columns are found in an analytical form and compared with the FEM solution. Sufficient accuracy of the results is worth of noticing.
Citations
-
6
CrossRef
-
0
Web of Science
-
7
Scopus
Authors (2)
Cite as
Full text
full text is not available in portal
Keywords
Details
- Category:
- Articles
- Type:
- artykuł w czasopiśmie wyróżnionym w JCR
- Published in:
-
THIN-WALLED STRUCTURES
no. 113,
pages 111 - 121,
ISSN: 0263-8231 - Language:
- English
- Publication year:
- 2017
- Bibliographic description:
- Szymczak C., Kujawa M.: Distortional buckling of thin-walled columns of closed quadratic cross-section// THIN-WALLED STRUCTURES. -Vol. 113, (2017), s.111-121
- DOI:
- Digital Object Identifier (open in new tab) 10.1016/j.tws.2017.01.006
- Verified by:
- Gdańsk University of Technology
seen 140 times