Abstract
This paper concerns measurement procedures on an emotion monitoring stand designed for tracking human emotions in the Human-Computer Interaction with physiological characteristics. The paper addresses the key problem of physiological measurements being disturbed by a motion typical for human-computer interaction such as keyboard typing or mouse movements. An original experiment is described, that aimed at practical evaluation of measurement procedures performed at the emotion monitoring stand constructed at GUT. Different locations of sensors were considered and evaluated for suitability and measurement precision in the HumanComputer Interaction monitoring. Alternative locations (ear lobes and forearms) for skin conductance, blood volume pulse and temperature sensors were proposed and verified. Alternative locations proved correlation with traditional locations as well as lower sensitiveness to movements like typing or mouse moving, therefore they can make a better solution for monitoring the Human-Computer Interaction
Citations
-
2 1
CrossRef
-
0
Web of Science
-
2 5
Scopus
Author (1)
Cite as
Full text
- Publication version
- Accepted or Published Version
- DOI:
- Digital Object Identifier (open in new tab) 10.2478/mms-2014-0049
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuł w czasopiśmie wyróżnionym w JCR
- Published in:
-
Metrology and Measurement Systems
no. 21,
edition 4,
pages 719 - 732,
ISSN: 0860-8229 - Language:
- English
- Publication year:
- 2014
- Bibliographic description:
- Landowska A.: Emotion Monitoring – Verification of Physiological Characteristics Measurement Procedures// Metrology and Measurement Systems. -Vol. 21, iss. 4 (2014), s.719-732
- DOI:
- Digital Object Identifier (open in new tab) 10.2478/mms-2014-0049
- Verified by:
- Gdańsk University of Technology
Referenced datasets
- dataset Short-term measurement of physiological parameters - teenager (15 min)
- dataset Short-term measurement of physiological parameters - teenager (5 min) - 3.series
- dataset Short-term measurement of physiological parameters - teenager (5 min)
- dataset Short-term measurement of physiological parameters - teenager (10 min)
- dataset Short-term measurement of physiological parameters - teenager (5 min) 7.series
- dataset Short-term measurement of physiological parameters - teenager (20 min) 2.series
- dataset Short-term measurement of physiological parameters - teenager (15 min)
- dataset Short-term measurement of physiological parameters - teenager (25 min)
- dataset Short-term measurement of physiological parameters - teenager (10 min)_3.series
- dataset Short-term measurement of physiological parameters - teenager (30 min)
seen 126 times