Methylene Blue Near-Infrared Fluorescence Imaging in Breast Cancer Sentinel Node Biopsy - Publication - Bridge of Knowledge

Search

Methylene Blue Near-Infrared Fluorescence Imaging in Breast Cancer Sentinel Node Biopsy

Abstract

Introduction: Fluorescence-based navigation for breast cancer sentinel node biopsy is a novel method that uses indocyanine green as a fluorophore. However, methylene blue (MB) also has some fluorescent properties. This study is the first in a clinical series presenting the possible use of MB as a fluorescent dye for the identification of sentinel nodes in breast sentinel node biopsy. Material and methods: Forty-nine patients with breast cancer who underwent sentinel node biopsy procedures were enrolled in the study. All patients underwent standard simultaneous injection of nanocolloid and MB. We visualized and assessed the sentinel nodes and the lymphatic channels transcutaneously, with and without fluorescence, and calculated the signal-to-background ratio (SBR). We also analyzed the corresponding fluorescence intensity of various dilutions of MB. Results: In twenty-three patients (46.9%), the location of the sentinel node, or the end of the lymphatic path, was visible transcutaneously. The median SBR for transcutaneous sentinel node location was 1.69 (range 1.66–4.35). Lymphatic channels were visible under fluorescence in 14 patients (28.6%) prior to visualization by the naked eye, with an average SBR of 2.01 (range 1.14–5.6). The sentinel node was visible under fluorescence in 25 patients (51%). The median SBR for sentinel node visualization with MB fluorescence was 2.54 (range 1.34–6.86). Sentinel nodes were visualized faster under fluorescence during sentinel node preparation. Factors associated with the rate of visualization included diabetes (p = 0.001), neoadjuvant chemotherapy (p = 0.003), and multifocality (p = 0.004). The best fluorescence was obtained using 40 M (0.0128 mg/mL) MB, but we also observed a clinically relevant dilution range between 20 M (0.0064 mg/mL) and 100 M (0.032 mg/mL). Conclusions: For the first time, we propose the clinical usage of MB as a fluorophore for fluorescence-guided sentinel node biopsy in breast cancer patients. The quenching effect of the dye may be the reason for its poor detection rate. Our analysis of different concentrations of MB suggests a need for a detailed clinical analysis to highlight the practical usefulness of the dye.

Citations

  • 6

    CrossRef

  • 0

    Web of Science

  • 7

    Scopus

Authors (10)

Keywords

Details

Category:
Articles
Type:
artykuły w czasopismach
Published in:
Cancers no. 14,
ISSN: 2072-6694
Language:
English
Publication year:
2022
Bibliographic description:
Budner O., Cwalinski T., Skokowski J., Marano L., Resca L., Cwalina N., Kalinowski L., Hoveling R., Roviello F., Polom K.: Methylene Blue Near-Infrared Fluorescence Imaging in Breast Cancer Sentinel Node Biopsy// Cancers -Vol. 14,iss. 7 (2022), s.1817-
DOI:
Digital Object Identifier (open in new tab) 10.3390/cancers14071817
Sources of funding:
  • Free publication
Verified by:
Gdańsk University of Technology

seen 100 times

Recommended for you

Meta Tags