Abstract
The paper presents the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type –HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. Classification of the air samples with respect to the place of collection relative to the landfill was performed using linear discriminant function supported with cross-validation method. More than 70 % of the samples were correctly classified employing the analysis with HERACLES II. The prototype of electronic nose provided correct classification of 40 % of the samples.
Citations
-
0
CrossRef
-
0
Web of Science
-
3 6
Scopus
Authors (3)
Cite as
Full text
full text is not available in portal
Keywords
Details
- Category:
- Articles
- Type:
- artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
- Published in:
-
CHEMICAL ENGINEERING TRANSACTIONS
no. 40,
pages 85 - 90,
ISSN: 2283-9216 - Language:
- English
- Publication year:
- 2014
- Bibliographic description:
- Gębicki J., Dymerski T., Namieśnik J.: Monitoring of Odour Nuisance from Landfill Using Electronic Nose// CHEMICAL ENGINEERING TRANSACTIONS. -Vol. 40., (2014), s.85-90
- DOI:
- Digital Object Identifier (open in new tab) 10.3303/cet1440015
- Verified by:
- Gdańsk University of Technology
seen 226 times