Abstract
Ceramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily detect enamel layer defects. The object under test is a sample ceramic plate with several defects occurring in production process. Results of OCT imaging show those defects are only in enamel layer without any effect on potsherd layer.
Authors (5)
Cite as
Full text
- Publication version
- Accepted or Published Version
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
- Published in:
-
Photonics Letters of Poland
no. 6,
pages 139 - 141,
ISSN: 2080-2242 - Language:
- English
- Publication year:
- 2014
- Bibliographic description:
- Trojanowski M., Kraszewski M., Strąkowski M., Kosmowski B., Pluciński J.: Polarization-sensitive optical coherence tomography for ceramic materials inspection// Photonics Letters of Poland. -Vol. 6., nr. 4 (2014), s.139-141
- Verified by:
- Gdańsk University of Technology
seen 103 times