Minichannel and minigap classification criteria based on the aspect ratio of the minigeometry: A numerical study
PublicationA detailed numerical investigation has been carried out to analyze the diabatic flow distribution and velocity profile in 18 minigeometries with various aspect ratios for V-type and I-type flow configurations (for 36 cases) assuming ethanol as a working fluid. The aim of the study is to distinguish the value of the aspect ratio for which the flow in minigeometry starts to be two-dimensional (minigap). Cases with a constant Reynolds...
-
Mitigation of the Flow Maldistribution in Minichannel and Minigap Heat Exchangers by Introducing Threshold in the Manifolds
PublicationIn the present paper, a detailed numerical investigation has been carried out to analyze the flow maldistribution in 50 parallel rectangular cross-section (1 mm depth and 1 mm width) minichannels and minigap section (1 mm depth and 99 mm width) with rectangular/trapezoidal manifolds in Z-type flow configuration. The author carried out numerical investigation with various mass flowrates, namely 0.05 kg/s, 0.1 kg/s and 0.2 kg/s which...
-
Flow maldistribution and its mitigation in mini heat exchangers
PublicationIn the present paper, a detailed numerical investigation has been carried out to analyze the flow maldistribution in 50 parallel 1 mm x 1 mm rectangular minichannels and 1 mm depth minigap section with rectangular, trapezoidal, triangular or concave mani-folds in Z-type flow configuration (16 different cases). The working medium was ethanol and the mass flow rate was 5×10-4 kg/s. Both sections was heated from the bottom side. Heat...
-
Flow Boiling in Minigap in the Reversed Two-Phase Thermosiphon Loop
PublicationThe paper presents the results of experimental investigations of a model of a heat exchanger featuring a minigap, which is perceived as an evaporator for an inverted thermosiphon. The system works with a single component test fluid. The tested evaporator generates pumping power in the test loop in a way similar to the mammoth pump. The tests regarded a module of the heat exchanger, consisting of a hot leg and a cold leg with the...