dr hab. inż. Jacek Gębicki
Zatrudnienie
- Dyrektor Centrum Technologii Wodorowych w Centrum Technologii Wodorowych
- Kierownik katedry w Katedra Inżynierii Procesowej i Technologii Chemicznej
- Profesor uczelni w Katedra Inżynierii Procesowej i Technologii Chemicznej
Publikacje
Filtry
wszystkich: 204
Katalog Publikacji
-
Quality evaluation of agricultural distillates using different types of electronic noses
PublikacjaThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with TGS type semiconductor sensors. HERACLES II included two chromatographic columns with different polarity of stationary phase and two FID detectors. In case of the prototype volatile fraction...
-
Comparison of Quality Evaluation of Agricultural Distillates Using Prototype of Electronic Nose and Fast/Flash GC
PublikacjaThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. In case of the prototype volatile fraction of the agricultural distillate was prepared via barbotage process. HERACLES II analysed the...
-
Studies on origin of Polish honeys by two-dimensional gas chromatography Ocena pochodzenia surowcowego polskich miodów przy użyciu dwuwymiarowej chromatografii gazowej
PublikacjaPolish acacia, linden, rapessed and buckwheat-derived honeys and a honydew were analysed for presence of hydrocarbons, alcs., ketones and esters by 2-dimensional gas chromatog. to establish the markers for the honey origin. PrOH was found characteristic for acacia honey, Me(CH2)11OH for linden honey, Me(CH2)6CHOMe for honeydew and Me(CH2)8COOEt for the rapeseed honey. Wykorzystano technikę dwuwymiarowej chromatografii gazowej sprzężonej...
-
THE USE OF ULTRAFAST GAS CHROMATOGRAPHY FOR CLASSIFICATION OF PLUM SPIRITS = SPOSÓB WYKORZYSTANIA ULTRASZYBKIEJ CHROMATOGRAFII GAZOWEJ DO KLASYFIKACJI OKOWIT ŚLIWKOWYCH
PublikacjaStan środowiska ma znaczny wpływ na jakość upraw. W konsekwencji występowanie zanieczyszczeń w powietrzu ma istotny wpływ na jakość żywności. W skutek złego stanu powietrza zewnętrznego i wewnętrznego zmieniają się m.in. walory sensoryczne i zdrowotne niektórych produktów spożywczych. Z tego powodu należy nieustannie monitorować stan środowiska za pomocą m.in. nowoczesnej aparatury analitycznej jakim jest elektroniczny nos. W...
-
POTENTIAL APPLICATIONS OF ELECTRONIC NOSE BASED ON ULTRA FAST GAS CHROMATOGRAPHY TO DISTINGUISH ALCOHOLIC BEVERAGES MADE OF GRAIN = POTENCJALNE MOŻLIWOŚCI ZASTOSOWANIA ELEKTRONICZNEGO NOSA OPARTEGO NA ULTRA SZYBKIEJ CHROMATOGRAFII GAZOWEJ DO ODRÓŻNIANIA NAPOJÓW SPIRYTUSOWYCH POCHODZENIA ZBOŻOWEGO
PublikacjaStan środowiska a zwłaszcza powietrza ma wpływ na wiele aspektów życia, m in. na jakość produktów spożywczych. Z tego względu niezwykle ważne jest monitorowanie stanu środowiska, które odbywa się za pomocą wielu technik analitycznych. Jedną z nich jest elektroniczny nos. Pierwotnie elektroniczny nos był wykorzystywany tylko do badania uciążliwości zapachowej powietrza. Obecnie technika ta wykorzystywana jest również do monitorowania...
-
ODOUR IMPACT OF MUNICIPAL LANDFILL MONITORED WITH ULTRA-FAST GAS CHROMATOGRAPHY = ODDZIAŁYWANIE ZAPACHOWE SKŁADOWISKA ODPADÓW KOMUNALNYCH MONITOROWANE ZA POMOCĄ ULTRA SZYBKIEJ CHROMATOGRAFII GAZOWEJ
PublikacjaPrzedstawiono wyniki badań klasyfikacji próbek powietrza atmosferycznego pobranych wokół miejskiego składowiska odpadów komunalnych w okresie zimowym i letnim pod kątem uciążliwości zapachowej. Badania przeprowadzono przy pomocy komercyjnego elektronicznego nosa typu Fast/Flash GC - HERACLES II. Klasyfikację próbek powietrza atmosferycznego pobranych z różnych kierunków względem wysypiska śmieci przeprowadzano przy użyciu dyskryminacyjnej...
-
Testy równoważności metod pomiarowych dla pyłu zawieszonego pm10
PublikacjaCelem prowadzonych badań było wykazanie równoważności metody wagowej oznaczania pyłu PM10, spełniającej wymogi referencyjności, z metodami oznaczania "on-site" dla losowo dobranych par danych (4 symulacje). We wszystkich przypadkach równoważność określona została za pomocą trzech odrębnych analiz: zgodnie z procedurą opisaną w Normie Europejskiej EN 12341:1998 oraz z wykorzystaniem analiz regresji ortogonalnej i liniowej, w celu...
-
Szacowanie zawartości benzo(a)pirenu w pyle zawieszonym pm10 przy pomocy wielowymiarowej regresji liniowej
PublikacjaW pracy przedstawiono próbę oszacowania przy pomocy wielowymiarowej regresji liniowej modelu empirycznego opisującego czynniki wpływające na zawartość B(a)P w pyle zawieszonym PM10 w jednej z dzielnic aglomeracji trójmiejskiej, gdzie głównym źródłem występowania B(a)P była niska emisja, spowodowana spalaniem paliw kopalnianych. Analizie poddano wzajemne zależności: stężenia pyłu PM10 w powietrzu, temperaturę powietrza, prędkość...
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublikacjaThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
-
Prototypowy czujnik do oznaczania lotnych związków opganicznych w powietrzu
PublikacjaW pracy zaprezentowano prototypowy elektrochemiczny czujnik zbudowany na bazie cieczy jonowej do oznaczania związków z grupy lotnych związków organicznych (LZO). W czujniku zostały użyte komercyjne elektrody firmy DropSens. w postaci pasków z nadrukowanymi elektrodami na ceramicznym podłożu. Jako elektrolit i środowisko reakcji redox wykorzystano następujące ciecze jonowe: dicyjanoamid 1-butylo-3-metyloimidazoliowy ([BMIM][N(CN2)]),...
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Comparison of the tests for equivalence of the measurement methods for measurement of PM10 dust in ambient air
PublikacjaThe paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on 'on-site' measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standard and the European Union (EU) guidelines,...
-
Electrochemical sensor for measurement of volatile organic compounds = Elektrochemiczny czujnik do oznaczania lotnych związków organicznych
PublikacjaPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania benzaldehydu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako technikę detekcyjną woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym były ciecze jonowe: chlorek 1-heksylo,3- metyloimidazolinowy i bis(trifluorometylosulfonylo)imidek...
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublikacjaPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
-
Istota testu równoważności dla metod pomiarowych pyłu zawieszonego PM10 w powietrzu atmosferycznym
PublikacjaW pracy przedstawiono przyczyny przeprowadzania testów równoważności i występowania różnic wartości stężeń pyłu PM10 uzyskiwanych metodą referencyjną a metodami opartymi na pomiarze "on-site". Omówiono metodę referencyjną i metody niereferencyjne oznaczania pyłu PM10 w powietrzu. Przeanalizowano testy równoważności (terenowe) przeprowadzane przez Fundację ARMAAG na terenie Trójmiasta. Przedstawiono współczynniki korekcyjne uzyskane...
-
Ekspertyza dotycząca bezzasadności zarzutów odnośnie parametrów metrologicznych analizatorów pyłu PM2,5 postawionych firmom EAS Envimet Polska Sp. z o.o. i EAS Envimet Analytical Systems GmbH przez spółkę MLU Sp. z o.o. z siedzibą w Katowicach w postępowaniu odwoławczym o sygn. akt: KIO/UZP 435/09
PublikacjaW ekspertyzie sporządzonej dla EAS Envimet Polska sp. z o.o. z siedzibą w Wieliczce wykazano bezzasadność zarzutów zgłoszonych przez Spółkę MLU w Katowicach w odniesieniu do urządzenia BAM1020 w postępowaniu odwoławczym toczącym się przed Prezesem Urzędu Zamówień Publicznych w związku z zaskarżeniem rozstrzygnięcia przetargu o zamówienie publiczne nr DM/5211-06-02/09/ABA na zakup automatycznego miernika pyłu zawieszonego PM2,5...
-
Test równoważności metod pomiarowych stosowanych do oznaczania pyłu zawieszonego PM10
PublikacjaW pracy przedstawiono przyczyny wystepowania różnic wartości stężeń pyłu PM10 uzyskiwanych metodą referencyjną a metodami opartymi na pomiarze w trybie on-site. Przedyskutowano metodykę wyznaczania równania bądź współczynnika korekcyjnego dla ciągłych metod pomiarowych w oparciu o unijną dyrektywę. Przeprowadzono weryfikację tej metodyki korzystając z danych uzyskanych z testu terenowego. Wyznaczono równanie korekcyjne przy pomocy...
-
Gazowe czujniki amperometryczne - perspektywy i wyzwania
PublikacjaW pracy przedstawiono stan wiedzy na temat gazowych czujników amperometrycznych z uwzględnieniem wprowadzanych przez konstruktorów zmian umożliwiających uzyskanie poprawy parametrów metrologicznych czujnika. Dokonano oceny skonstruowanych własnych prototypów czujników do oznaczania ditlenku siarki. Przedstawiono potencjalne możliwości sprzężenia technik izolacji (absorpcji i ekstrakcji membranowej) z detekcją amperometryczną w...
-
Bezpośrednia analiza próbek z wykorzystaniem techniki spektrometrii mas. Cz. I. Rozwiązania metodyczne w zakresie spektrometrii mas umożliwiające bezpośrednią analizę próbek
PublikacjaTechnika spektrometrii mas stanowi jedno z najważniejszych narzędzi analitycznych, wykorzystywanych do identyfikacji, określania struktury chemicznej oraz oznaczania stężeń wielu związków chemicznych. Aby zidentyfikować obecne w próbkach rzeczywistych anality, konieczne jest jednak z reguły ich wstępne rozdzielenie, toteż spektrometry mas pełnią najczęściej rolę detektora np. w przypadku technik łączonych, gdy na etapie rozdzielania...
-
Determination of benzo(a)pyrene content in PM10 using regression methods
PublikacjaThe paper presents an attempt of application of multidimensional linear regression to estimation of an empirical model describing the factors influencing on B(a)P content in suspended dust PM10 in Olsztyn and Elbląg city regions between 2010 and 2013. During this period annual average concentration of B(a)P in PM10 exceeded the admissible level 1.5-3 times. Conducted investigations confirm that the reasons of B(a)P concentration...
wyświetlono 7033 razy