The standard radiated immunity test of an astable multivibrator at a normative field strength - Open Research Data - MOST Wiedzy

Wyszukiwarka

The standard radiated immunity test of an astable multivibrator at a normative field strength

Opis

The dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz are performed under the requirements specified in the electromagnetic compatibility (EMC) standards.
In laboratory conditions, the electromagnetic fields were simulated in the GTEM (Gigahertz Transverse Electromagnetic) cell (Fig. 1). An integrated signal generator, equipped with a built-in 45 W class A power amplifier module, was used in the measurement setup. The tested multivibrator was supplied from a battery of 9 V or externally from the NN DF1723003TC power supply. The signal cable connected to the input of an oscilloscope was led out of the tested PCB. The measurement process was controlled by the WIN 6000 software installed on a personal computer connected to the signal generator via the IEEE488 interface.

Ilustracja publikacji

Figure 1. Configuration of the measuring system for testing the immunity of electronic systems
in the GTEM cell

A typical astable multivibrator built on bipolar transistors T3 and T4 was subjected to the immunity test (Fig. 2). The proper operation of the device is showed by flashing LEDs with variable frequency. A signal wire was led out from the collector of the transistor T3 and connected to the oscilloscope input. The system sensitivity to the radiated field in the GTEM cell was assessed based on the observation of the changes in the shape of the signal waveform controlling diode switching.

The normative test procedure was carried out in the frequency range starting at 80 MHz and incrementing in 1% steps up to at least 1 GHz. The RF signal was modulated with a sinusoidal signal with a frequency of 1 kHz and a modulation depth of 80%. Immunity tests were made for three different levels of the electromagnetic field strength 1 V/m, 3 V/m and 10 V/m, respectively. The position of the equipment under test in the uniform area of the GTEM cell was changed for three orthogonal orientations x, y, z (Fig. 3). During the measurements, on the oscilloscope, the differences in the shape of the voltage waveform to the reference waveforms recorded with the signal generator turned off were being observed. 
The attached files contain oscillograms showing the voltage waveforms from the PCB that deviate the most from the reference waveform. For each case, information about the RF frequency of the signal generator is included in the file description.

Ilustracja publikacji
Ilustracja publikacji

Figure 2. The electronic diagram of the AVT 720 system

Figure 3. The schematic diagram of a GTEM cell. Presented dimensions are for Teseq GTEM 500

Plik z danymi badawczymi

Immunity_normative.zip
6.9 MB, S3 ETag 01361e2657419e392eea04d2e0925115-1, pobrań: 68
Hash pliku liczony jest ze wzoru
hexmd5(md5(part1)+md5(part2)+...)-{parts_count} gdzie pojedyncza część pliku jest wielkości 512 MB

Przykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5
pobierz plik Immunity_normative.zip

Informacje szczegółowe o pliku

Licencja:
Creative Commons: by 4.0 otwiera się w nowej karcie
CC BY
Uznanie autorstwa

Informacje szczegółowe

Rok publikacji:
2021
Data zatwierdzenia:
2021-06-28
Data wytworzenia:
2016
Język danych badawczych:
angielski
Dyscypliny:
  • Automatyka, elektronika i elektrotechnika (Dziedzina nauk inżynieryjno-technicznych)
DOI:
Identyfikator DOI 10.34808/1w2q-xp19 otwiera się w nowej karcie
Seria:
Weryfikacja:
Politechnika Gdańska

Słowa kluczowe

Powiązane zasoby

Cytuj jako

wyświetlono 142 razy