Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 108 mA. Sample J51.
Opis
Dataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 108 mA. Sample J51.
The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission. For sample charging and discharging the ATLAS 1361 MPG&T was used.
The sample is in a form of triplex envelope (6 cm x 7 cm) with active structure (2,5 cm x 4 cm) inside and electrodes contacts at one of envelope edge.
The ASCII text data file consists of images acquired within a fixed period of measurement, T = 180 sec. The recorded image is a matrix containing 388 x 288 temperature data. Each image is preceded with header with image number, date and time of acquisition.
Plik z danymi badawczymi
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
gdzie pojedyncza część pliku jest wielkości 512 MBPrzykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5
Informacje szczegółowe o pliku
- Licencja:
-
otwiera się w nowej karcieCC BYUznanie autorstwa
- Dane surowe:
- Dane zawarte w datasecie nie zostały w żaden sposób przetworzone.
Informacje szczegółowe
- Rok publikacji:
- 2021
- Data zatwierdzenia:
- 2021-09-27
- Język danych badawczych:
- angielski
- Dyscypliny:
-
- Automatyka, elektronika i elektrotechnika (Dziedzina nauk inżynieryjno-technicznych)
- DOI:
- Identyfikator DOI 10.34808/gxbv-g758 otwiera się w nowej karcie
- Finansowanie:
- Seria:
- Weryfikacja:
- Politechnika Gdańska
Słowa kluczowe
Powiązane zasoby
- publikacja Temperature distribution of supercapacitors prepared by various technologies
- publikacja Electrochemical capacitor temperature fluctuations during charging/discharging processes
Cytuj jako
Autorzy
wyświetlono 96 razy