Identification of dynamic parameters in the context of diagnostics of steel tank with different level of liquid. - Publikacja - MOST Wiedzy

Wyszukiwarka

Identification of dynamic parameters in the context of diagnostics of steel tank with different level of liquid.

Abstrakt

The paper presents an experimental study to identify the dynamic parameters of a water-filled tank model. The experimental modal analysis approach involving the excitation at one point of the structure and acquisition of vibra tions at selected points distri buted over the tank surface allowed to determine the resonance frequencies, mode shapes and damping ratios. The main aim of the research was to examine the influence of the level of liquid on the modal parameters. The experimental study showed that the level of water in the tank had an important impact on the values of natural frequenc ies and damping ratios.

Cytuj jako

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
Opublikowano w:
Diagnostyka nr 16, strony 9 - 14,
ISSN: 1641-6414
Język:
angielski
Rok wydania:
2015
Opis bibliograficzny:
Rucka M., Zielińska M.: Identification of dynamic parameters in the context of diagnostics of steel tank with different level of liquid.// Diagnostyka. -Vol. 16., iss. 1 (2015), s.9-14