Polarization-sensitive optical coherence tomography for ceramic materials inspection - Publikacja - MOST Wiedzy

Wyszukiwarka

Polarization-sensitive optical coherence tomography for ceramic materials inspection

Abstrakt

Ceramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily detect enamel layer defects. The object under test is a sample ceramic plate with several defects occurring in production process. Results of OCT imaging show those defects are only in enamel layer without any effect on potsherd layer.

Cytuj jako

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
Opublikowano w:
Photonics Letters of Poland nr 6, strony 139 - 141,
ISSN: 2080-2242
Język:
angielski
Rok wydania:
2014
Opis bibliograficzny:
Trojanowski M., Kraszewski M., Strąkowski M., Kosmowski B., Pluciński J.: Polarization-sensitive optical coherence tomography for ceramic materials inspection// Photonics Letters of Poland. -Vol. 6., nr. 4 (2014), s.139-141