The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
Abstrakt
In recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research was to develop a novel calibration method for PISSs fabricated with the use of an all-solid-state technology, which has been compared with other types of sensor calibration technique. The proposed algorithm concerns the method of calibration solutions composition determination for miniature ion-selective sensors before measuring in biological samples especially human saliva samples. This article also compares the parameters of ion-selective sensors for two types of PISSs, including ISEs based on gold (Au) and glassy carbon (GC) electrodes. In addition, a series of measurements was performed using PISS with Au-ISEs in samples of human saliva, which were preceded by different types of sensor calibration and compared with the results obtained with the clinical analyzer. Moreover, the effect of the viscosity of calibration solutions on the ISE parameters and the lifetime of the sensors were investigated.
Cytowania
-
6
CrossRef
-
0
Web of Science
-
6
Scopus
Autorzy (4)
Cytuj jako
Pełna treść
- Wersja publikacji
- Accepted albo Published Version
- Licencja
- otwiera się w nowej karcie
Słowa kluczowe
Informacje szczegółowe
- Kategoria:
- Publikacja w czasopiśmie
- Typ:
- artykuł w czasopiśmie wyróżnionym w JCR
- Opublikowano w:
-
JOURNAL OF SOLID STATE ELECTROCHEMISTRY
nr 23,
strony 2251 - 2260,
ISSN: 1432-8488 - Język:
- angielski
- Rok wydania:
- 2019
- Opis bibliograficzny:
- Urbanowicz M., Pijanowska D., Jasiński A., Bocheńska M.: The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems// JOURNAL OF SOLID STATE ELECTROCHEMISTRY. -Vol. 23, iss. 7 (2019), s.2251-2260
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1007/s10008-019-04323-4
- Bibliografia: test
-
- Lewenstam A (2014) Electroanalysis 26(6):1171-1181 otwiera się w nowej karcie
- Mousavi Z, Granholm K, Sokalski T, Lewenstam A (2015) Sensors Actuators B 207:895-899 otwiera się w nowej karcie
- Jasiński A, Urbanowicz M, Guziński M, Bocheńska M (2015) Electroanalysis 27(3):745-751 otwiera się w nowej karcie
- Yin T, Pan D, Qin W (2014) Anal Chem 86(22):11038-11044 otwiera się w nowej karcie
- Bobacka J, Ivaska A, Lewenstam A (2008) Chem Rev 108(2):329- 338 otwiera się w nowej karcie
- Lewenstam A, Bobacka J, Ivaska A (1994) J Electroanal Chem 23: 23-28 otwiera się w nowej karcie
- Oyama N, Hirokawa T, Yamaguchi S, Ushizawa N, Shimomura T (1987) Anal Chem 59(2):258-264 otwiera się w nowej karcie
- Guzinski M, Jarvis JM, D'Orazio P, Izadyar A, Pendley BD, Lindner E (2017) Anal Chem 89(16):8468-8475 otwiera się w nowej karcie
- Cui J, Lisak G, Strzalkowska S, Bobacka J (2014) Analyst 139(9): 2133-2136 otwiera się w nowej karcie
- Blaz T, Baś B, Kupis J, Migdalski J, Lewenstam A (2013) Electrochem Commun 34:181-184 otwiera się w nowej karcie
- Lindner E, Pendley BD (2013) Anal Chim Acta 762:1-13 otwiera się w nowej karcie
- Urbanowicz M, Jasiński A, Jasińska M, Drucis K, Ekman M, Szarmach A, Suchodolski R, Pomećko R, Bocheńska M (2017) Electroanalysis 29(10):2232-2238 otwiera się w nowej karcie
- Mohan MS, Bates G (1975) Clin Chem 21(7):864-872 otwiera się w nowej karcie
- Baret M, Massart DL, Fabry P, Conesa F, Eichner C, Menardo C (2000) Talanta 51(5):863-877 otwiera się w nowej karcie
- Oesch U, Ammann D, Simon W (1986) Clin Chem 32:1448-1459 otwiera się w nowej karcie
- Horvai G, Toth K, Pungor E (1976) Anal Chim Acta 82(1):45-54 otwiera się w nowej karcie
- Sáez de Viteri FJ, Diamond D (1994) Analyst 119(5):749-758
- Beebe KR, Kowalski BR (1988) Anal Chem 60(20):2273-2278 otwiera się w nowej karcie
- Lisak G, Ivaska A, Lewenstam A, Bobacka J (2014) Electrochim Acta 140:27-32 otwiera się w nowej karcie
- Lisak G, Arnebrant T, Lewenstam A, Bobacka J, Ruzgas T (2016) Anal Chem 88(6):3009-3014 otwiera się w nowej karcie
- Joon NK, He N, Wagner M, Cárdenas M, Bobacka J, Lisak G (2017) Electrochim Acta 252:490-497 otwiera się w nowej karcie
- Stokes RH, Robinson RA (1948) J Am Chem Soc 70(5):1870- 1878 otwiera się w nowej karcie
- Cammann K (1979) Working with ion-selective electrodes. Springer-Verlag, Berlin otwiera się w nowej karcie
- Schipper RG, Silletti E, Vingerhoedes MH (2007) Arch Oral Biol 52(12):1114-1135 otwiera się w nowej karcie
- Roberts BJ (1977) J Dent 5(4):303-309 otwiera się w nowej karcie
- Vissink A, Waterman HA, 'S-Gravenmade EJ, Panders AK, Vermay A (1984) J Oral Pathol 13(1):22-28 otwiera się w nowej karcie
- Van Der Reijden WA, Veerman ECI, Van Nieuw Amergongen A (1994) Biorheology 31:631-642 otwiera się w nowej karcie
- Pomećko R, Asfari Z, Hubscher-Bruder V, Bocheńska M, Arnaud- Neu F (2010) Supramol Chem 22(5):275-288 otwiera się w nowej karcie
- Pomećko R, Asfari Z, Hubscher-Bruder V, Bocheńska M, Arnaud- Neu F (2007) Supramol Chem 7:459 otwiera się w nowej karcie
- Urbanowicz M, Pijanowska DG, Jasiński A, Bocheńska M (2018) XV International scientific conference on optoelectronic and elec- tronic sensors (COE). DOI: https://doi.org/10.1109/COE.2018. 8435148. otwiera się w nowej karcie
- Guziński M (2013), Dissertation: development of all-solid-state po- tentiometric measurement system to determine concentration of lead (II) cations, Gdańsk University of Technology, 2013.
- Aps JKM, Martens LC (2005) Forensic Sci Int 150(2-3):119-131 otwiera się w nowej karcie
- Hosseini M, Ghalami-Choobar B, Zanjanchi M-A (2015) Phys Chem Res 3:305-318 otwiera się w nowej karcie
- Umezawa Y, Buhlmann P, Umezawa K, Tohda K, Amemiya S (2000) Pure and Appl. Chem. 71:1851-2082 otwiera się w nowej karcie
- Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. otwiera się w nowej karcie
- Weryfikacja:
- Politechnika Gdańska
wyświetlono 138 razy
Publikacje, które mogą cię zainteresować
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
- U. Marcin,
- D. G. Pijanowska,
- A. Jasiński
- + 1 autorów
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
- M. Urbanowicz,
- K. Sadowska,
- D. G. Pijanowska
- + 2 autorów