dr hab. inż. Bogdan Chachulski
Publications
Filters
total: 62
Catalog Publications
Year 2016
-
Investigation of solid polymer electrolyte gas sensor with different electrochemical techniques
PublicationIn this work solid polymer electrolyte (SPE) amperometric sulphur dioxide sensor is investigated. Nafion was used as a membrane electrode and 1M sulphuric acid as an internal electrolyte. Sensor response to sulphur dioxide was measured. Besides traditional constant voltage amperometry also different electrochemical techniques were used. Results obtained by these methods are compared.
Year 2015
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
Year 2014
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublicationIn this work investigation of an amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode properties is presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been studied.
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublicationIn this paper performance of an electrocatalytic sensor in presence of chlorine is investigated. Presented studies concern sensor prepared in ceramic technology based on NASICON as a solid electrolyte with two round shaped platinum electrodes. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Preparation and characterisation of solution-cast Nafion membrane
PublicationNafion is a commercial name for a perfluorosulfonic polymer, which has been developed in 1962 by Dupont de Nemours. This polymer consists of a polytetrafluoroethylene backbone and regular spaced long perfluorovinyl ether pendant side chains terminated by a sulfonate ionic group. These sulfonate groups are responsible for cation-exchange properties of Nafion. Thanks to the ion-exchange properties, water permeability, good chemical,...
Year 2013
-
Badanie właściwości czujników wilgotności na bazie nanocząstek tlenku cynku
PublicationW celu pomiaru wilgotności szeroko stosowane są czujniki elektryczne. Warstwą czynną, zmieniającą swoje właściwości pod wpływem pary wodnej, stanowią najczęściej materiały ceramiczne lub polimerowe. Tlenek cynku jest jednym z materiałów ceramicznych będących dobrym kandydatem do zastosowania go jako warstwy czynną w czujnikach wilgotności. W tej pracy przedstawiono wyniki badań właściwości struktur czujnikowych z warstwą tlenku...
-
Construction and investigation of SO2 amperometric sensor with a solid polymer electrolyte membrane
Publicationn this paper a sensor for detection of the sulphur dioxide based on three electrode cell configuration with a liquid electrolyte, a mercury sulphate reference electrode and a solid polymer electrolyte working electrode is presented. Working elec- trode was obtained by using Takenaka-Torikai chemical deposi- tion method by precipitation of Au particles into the pores of the Nafion membrane. Sensors characteristics measurements were...
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublicationIn this work amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode will be presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been investigated.
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublicationProperties of sensor based on Nasicon with two round shaped platinum electrodes are investigated. Influence of different chlorine concentrations on the sensor response is presented. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Investigation of sensing mechanism of Nasicon electrocatalytic sensors in nitrogen dioxide and ammonia
PublicationIn this paper a sensing mechanism of Nasicon electrocatalytic sensor in nitrogen dioxide and ammonia is investigated. Both gases are environmentally hazardous and contain nitrogen atom in the molecule. However, it seems that their sensing mechanism in electrocatalytic sensor could be totally different. Namely, the maximum sensitivity for each gas was obtained at different temperatures. Also, different auxiliary layers are formed...
-
OPTIMIZATION OF NASICON PREPARATION METHOD
PublicationNasicon is a solid conductor which has an ability to conduct Na+ ions and it is used in solid gas sensors. In this article a method of Nasicon preparation appropriate for gas sensing application by solgel technique is presented. Influence of the fabrication process parameters on properties of obtained samples was determined. Results of X-Ray diffraction, density, porosity, conductivity, and activation energies measurement are presented.
Year 2012
-
Badanie właściwości czujnika elektrokatalitycznego na bazie tytanianu litowo-lantanowego
PublicationW pracy przedstawiono wyniki badań wpływu stężenie ditlenku azotu na kształt charakterystyk prądowo-napięciowych (I-V) nowego czujnika elektrokatalitycznego na bazie elektrolitu stałego z mobilnymi jonami litu LiLaTiO3. Czujnik ten został wykonany w technologii ceramicznej w formie pastylki z porowatymi elektrodami złotymi naniesionymi po obu jej stronach. Wykonano pomiary odpowiedzi czujnika w temperaturach 175ºC i 300ºC. Stężenie...
-
Electrocatalytic sensor based on Nasicon with auxiliary layer = Czujnik elektrokataliczny na bazie Nasiconu z warstwą dodatkową
PublicationW pracy zostały przedstawione wyniki pomiarów czujnika na bazie Nasiconu pracującego w trybie elektrokatalitycznym. Czujniki takie pobudzane są zmieniającym się napięciem przy jednoczesnym pomiarze odpowiedzi prądowej. Przygotowano czujniki ceramiczne o dwóch różnych typów. Pierwszy z nich to czujnik posiadający dwie identyczne elektrody złote, pomiędzy którymi znajduje się elektrolit stały. Drugi czujnik posiada złote elektrody...
-
Hydrogen sulphide electrocatalytic gas sensor
PublicationIn this article measurement results of the electrocatalytic gas sensor in different concentrations of hydrogen sulphide are presented. Working principle of such sensor is based on electric current acquisition, while voltage ramp is applied to the sensor. During voltage sweep oxidation and reduction reactions occurs on the sensor electrodes. Obtained current-voltage plot has unique shape connected...
-
Investigation of Sensing Mechanism of Nasicon Electrocatalytic Sensors in Nitrogen Dioxide and Ammonia
PublicationW pracy przedstawiono wyniki badań mechanizmu działania czujnika elektrokatalitycznego pracującego w ditlenku azotu i amoniaku.
-
Staircase Voltammetry Application to Electrocatalytic Gas Sensor
PublicationW pracy przedstawiono wyniki badań czujnika elektrokatalicznego pobudzanego sygnałem schodkowym w różnych mieszaninach gazowych .
Year 2011
-
Czujniki gazów toksycznych na bazie elektrolitów stałych
PublicationW pracy przedstawiono wyniki badań eksperymentalnych nad czujnikami wykorzystującymi technikę woltamperometrii cyklicznej zbudowanymi na bazie elektrolitów stałych. Czujniki te, ze względu na mechanizm pracy, nazywane są czujnikami elektrokatalitycznymi lub czujnikami wykorzystującymi kinetykę reakcji chemicznej.
-
Electrocatalytic gas sensor with non-triangular excitation = Czujnik elektrokatalityczny z pobudzeniem innym niż trójkątne
PublicationElektrokatalityczny czujnik gazu pracuje w trybie woltamperometrycznym. Pobudzony jest zmieniającym się napięciem przy jednoczesnym pomiarze prądowej odpowiedzi czujnika. Charakterystyka prądowo-napięciowa ma unikalny kształt, uzależniony od stężenia i rodzaju gazów w otoczeniu czujnika. Jako pobudzenie zazwyczaj stosowane jest napięcie liniowo narastające w zakresie od 5 V do -5 V napięcie o symetrycznym, trójkątnym kształcie....
-
electrocatalytic sensor based on nasicon with auxiliary layer
PublicationW pracy przedstawiono wyniki badań czujników elektrokatalitycznych z dodatkową warstwą. Właściwości takiego czujnika porównano z czujnikiem o tradycyjnej budowie.
-
Gas sensors based on superionic conductors
PublicationW pracy przedstawiono przegląd rozwiązań elektrochemicznych czujników gazów na bazie elektrolitów stałych.
seen 973 times