dr inż. Adam Bujnowski
Employment
- Assistant professor at Department of Biomedical Engineering
Publications
Filters
total: 109
Catalog Publications
Year 2024
-
A Novel Device and System for Fall Detection Under the Shower
PublicationIn this paper, device construction and preliminary results for shower safety assistance are presented. The device allows monitoring of shower-taking persons without violating privacy and intimacy, while it has the ability to detect a persons entering and leaving the shower and detecting fall conditions. It allows better supervision of elders living independently at their locations.
-
Diagnostics of the Peripheral Artery Disease with use of Glucose Sensor - A Proof of Concept
PublicationIt is estimated that 13 % of population over 50 years old suffer from symptomatic or asymptomatic peripheral artery disease (PAD). Ankle-brachial index (ABI) is viewed as a useful parameter in diagnostics of peripheral arterial disease, however screening tests with usage of this method are not advised. Hypoxia causes increase in lactate values and...
-
Diagnostics of the Peripheral Artery Disease with use of Glucose Sensor - A Proof of Concept
PublicationIt is estimated that 13% of population over 50 years old suffer from symptomatic or asymptomatic peripheral artery disease (PAD). Ankle-brachial index (ABI) is viewed as a useful parameter in diagnostics of peripheral arterial disease, however screening tests with usage of this method are not advised. Hypoxia causes increase in lactate values and decrease in blood glucose. We hypothesize that the deficit in blood supply to the...
-
Flap Monitoring Techniques: A Review
PublicationPostoperative tissue flap vitality monitoring enables early detection of clinical complications, allowing for intervention. Timely re-operation can prevent the need for extensive correction procedures, thus reducing healthcare costs and hospitalisation time. Statistics show that monitoring can increase the success rate of flap survival to 95\% or higher. However, despite the significant progress in monitoring techniques, major...
-
Pulse Transit Time - Fiducial Points Accuracy Determination as Examined by Means of Synthetic Signals
PublicationThere are many approaches to non-invasively deter-mine blood pressure. Among them there are methods based on utilizing pulse transit time measured by means of photoplethys-mography. The variability of the blood pressure drop between two measurement sensors placed along the artery and its dependence on the selected parameters describing the cardiovascular system is presented in the paper. This pressure drop modifies the pressure...
Year 2023
-
A review of methods of blood supply to organs of the gastrointestinal tract. State of art
PublicationThe correct assessment of blood supply is essential to eliminate possible postoperative complications. Re-anastomosis of the gastrointestinal tract after its resection must be preceded by the analysis of blood supply to the anastomosed fragments. It is important that the blood supply assessment procedure is reliable but also non-absorbing and, if possible, short. It should also be possible to repeat the procedure due to the need...
Year 2022
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
Year 2021
-
Coupling between Blood Pressure and Subarachnoid Space Width Oscillations during Slow Breathing
PublicationThe precise mechanisms connecting the cardiovascular system and the cerebrospinal fluid (CSF) are not well understood in detail. This paper investigates the couplings between the cardiac and respiratory components, as extracted from blood pressure (BP) signals and oscillations of the subarachnoid space width (SAS), collected during slow ventilation and ventilation against inspiration resistance. The experiment was performed on...
-
DETECTION OF BREATHING AND HEART RATE USING AN ECG SIGNAL MEASURED WHILE BATHING IN THE BATHTUB
PublicationNowadays a new area of interest is gaining importance - it is home biomedical examination. Intelligent home can be supported by set of devices for habitants observation. It can be particularly useful for elders or person with some health risks but living alone. One of critical locations within the house is bathroom. One of utilities in the bathroom is a bathtub which is sometimes preferred over shower. There are reports of problems...
-
Influence of preprocessing techniques on pulse pressure velocity determination
PublicationPulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...
-
Smart city and fire detection using thermal imaging
PublicationIn this paper, we summarize the results obtained from fire experiments. The aim of the work was to develop new methods of fire detection using IR thermal imaging cameras and dedicated image processing. We conducted 4 experiments in different configurations and with the use of different objects. The conducted experiments have shown the great usefulness of infrared cameras for detecting the seeds of a fire. Even cheap low-resolution...
Year 2020
-
Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
PublicationA non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...
-
Ella4Life virtual assistant - user centered design strategy - evaluation following labolatory tests
PublicationIn the paper, we summarize the evaluation of Anne4Care system after laboratory tests. A group of end users, seniors over 55 years of age, rated a virtual assistant by completing a questionnaire. The objectives of the pilot evaluations are mainly to assess the feasibility, usability, acceptance and functionality of the system and the ability of the potential target user to use the system and receive valuable information from it...
-
Optical sensor of a person sitting on a chair and dressed in multi-layered clothes vital signs monitoring
PublicationAn optoelectronic device enhancing a smart chair functionality is presented in the paper. Its essential purpose is a detection of a sitting person presence on the chair by means of detecting the vital signs. Additionally, it could be used for determining of clothes layer parameters useful in adjusting a system of a capacitive electrocardiography.
-
Respiratory signals derived from capacitive electrocardiogram on the smart chair
PublicationCapacitive electrocardiogram (CECG) tends to deliver basic cardiac signals without need to use traditional glued electrodes. In the paper analysis of possibility if the ECG derived respiratory waveforms out of the CECG.
Year 2019
-
Can we rely on the pulse transit time - pressure relationship - models comparison
PublicationAn unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
Estimation of electrode contact in capacitive ECG measurement
PublicationIn the paper a method of electrode’s contact estimation in capacitive electrocardiogram (CECG) is presented. Proposed solution allows estimation of contact quality for each individual electrode. This enables construction of multi-electrode CECG systems, where electrode pairs can be selected on the basis of the individual electrode contact quality.
-
Methodology for assessing end-user requirements in the Ella4Life project: elders’ perspectives about self-monitoring
PublicationThe purpose of this paper is to explore elders’ perspectives about self-monitoring and using specially developed sensor technology for measuring health indicators. The qualitative research method is focus-groups with guidelines that were designed for understanding elder’s requirements about monitoring health indicators. We present them two devices: the first sensor is a device for monitoring of cardiac action potential fixed into...
-
Optimal ECG lead for deriving respiratory signal
PublicationEDR is an interesting measuring technique that allows an indirect assessment of respiratory activity. This is an alternative solution to direct methods that are based on the measurement of air flow, which require a specialized sensor or even a system. However, due to inter-personal anatomical differences, the optimal ECG lead (placement of the electrodes) ensuring the best EDR signal quality is not fixed. An influence of ECG lead...
-
Respiratory signal of bathing person - preliminary study
PublicationThe scope of this paper is analysis of applicability of modern biomedical acquisition system installed in bathtub towards reception of respiratory signals of bathing person. An analysis of the possibility of such measurement is shown as well as preliminary results.
-
Sensors integration in the smart home environment - a proposal to solve the problem with user identification
PublicationIn this preliminary study we, investigate the possibility of user recognition techniques suitable on smart home devices like chairs, beds, aiming for low–power, high accuracy and quick response time. We propose the two well know technique: voice speaker recognition and accelerometer signal from device mounted on the chair, and the third one optical system basing on IR LED transmitter/receiver circuit. The preliminary results proved...
-
Systemy automatycznej detekcji bezdechu sennego
PublicationZgodnie z przyjętą klasyfikacją międzynarodową identyfikowanych jest ponad 60 różnych zaburzeń snu [58] z podziałem na 7 kategorii. Bezdech senny, zarówno centralny jak i obturacyjny zaliczany jest do kategorii drugiej. Systemy pomiarowe wykorzystywane w monitorowaniu i diagnozie snu, w tym wykorzystywane do detekcji bezdechu sennego, można sklasyfikować ze względu na wiele kryteriów, np. ze względu na to czy badania wykonywane...
-
Using Eye-tracking to get information on the skills acquisition by the radiology residents
PublicationThis paper describes the possibility of monitoring the progress of knowledge and skills acquisition by the students of radiology. It is achieved by an analysis of a visual attention distribution patterns during image-based tasks solving. The concept is to use the eye-tracking data to recognize the way how the radiographic images are read by recognized experts, radiography residents involved in the training program, and untrained...
-
ZINTEGROWANY SYSTEM DOMOWEGO MONITORINGU PARAMETRÓW MEDYCZNYCH OSÓB STARSZYCH I CHORYCH
PublicationProponowane rozwiązania mają na celu wspomaganie osób starszych i chorych, tak by mogły jak najdłużej mieszkać i żyć samodzielnie ze zwiększonym poczuciem bezpieczeństwa, iż są nadzorowane i w razie nagłego zagrożenia życia nie pozostaną bez pomocy. System jednocześnie nie narusza poczucia zachowania prywatności i intymności, gdyż nie są używane do monitoringu kamery wizyjne czy też stały nasłuch audio. Dodatkowo gromadzone informacje...
Year 2018
-
A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation
PublicationThe paper presents a preliminary meta-analysis of the sample correlation between pulse arrival time (PAT) and blood pressure (BP). The aim of the study was to verify sample correlation coefficient between PAT and BP using an affine model BP = a · P AT + b for systolic and diastolic blood pressure. The databases included in the search were the IEEE Xplore Digital Library, Springer Link and Google Scholar. Only papers from 2005 to...
-
Electrical Propterties of Solution Mixtures for Bath Supervision in Ambient Assisted Living
PublicationImpedance properties of bath solution are compared. Any ingredient such as soap, shampoo or bathing salt changes bath-solution’s electrical properties eg. impedance. We have measured and analysed influence of typical bathing ingredients on electrical properties of the solution. We investigate impedance changes over frequency range from 100Hz tu 100kHz as it is most applicable for person detection. Electrical properties of bath...
-
Smart heating system for home extending utilization of renewable energy sources
PublicationIn the paper a modern approach to smart home heating is presented. Proposed solution utilizes at least two low-polluting energy source technologies. The main idea is to connect well known ecological energy sources in a way that they can support each other and minimize risks of failure when using single system or even both of them but managed in separate way. Considered energy technologies, used separatelly, have disadvan-tages,...
-
Smart Weighing Scale with Feet-Sampled ECG
PublicationIn a smart home, health and well-being monitoring systems could be embedded in everyday devices providing a pervasive care. A home bathroom scale is an example of such a device, typically used to measure body weight and very often its composition (e.g. body water/fat percentage). In this paper, we analyzed a potential use of the bathroom scale to measure electrocardiogram (ECG) from electrodes located on the scale's tile. In particular...
-
Using Wearable Electronics to Estimate Usefulness of Heart Rate Variability for Bathing Person Identif Cation
PublicationIn this paper the possibility of person identification based on biosignal is investigated. The work focus on the analysis of the changes in intervals between successive R-waves of electrocardiogram (ECG) recorded by wearable electronics in form of a necklaces. The main idea behind this project is to find efficient tool which may prevent sudden consciousness loss episodes or even sudden death episodes related to rapid temperature...
Year 2017
-
A body position influence on ECG derived respiration
PublicationAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
A navigation device utilizing body communication channel for mobile wearable systems
PublicationA novel touch sensor utilizing a body communication technology is presented in the paper. The proposed device accepts orders (gestures) only from a person wearing it. Moreover, when comparing it to a similar, however an optical one, it appears as a less power consumable. Preliminary results of its properties examination are presented and discussed. Additionally, the developed sensor allows to measure a human body the electrical...
-
A novel sensor for measuring temperature profile during the thermoablation
PublicationAbstract — A novel approach for monitoring a temperature distribution inside a tissue during thermoablation is presented in the paper. A thermal profile is measured using a set of serially connected thermistors each bypassed by a capacitor. This technique allows a two-wire and simultaneous multi- point measurements using a multi-frequency measurement of electrical impedance. It is...
-
A scale with ECG measurements capability for home cardiac monitoring
PublicationPresented device -a scale developed for enabling extra measurements, in addition to body weight and composition, the electrical activity of the heart (electrocardiogram - ECG) and the level of oxygen saturation in the blood SaO2. Electrical activity is recorded in the form of six leads, socalled - limb leads. The device allows measurement of all standard limb leads and without the need for additional procedures. ECG, although the...
-
Capacitively coupled ECG measurements - a CMRR circuit improvement
PublicationA typical galvanic-connected electrocardiogram (ECG) measurement system utilizes two signal’s electrodes and a third one in driven-right-leg (DRL) circuit for improving a common-mode rejection ratio(CMRR) of the acquisition system. In capacitive-coupled ECG similar techniques are used, however it is expected, that the utilized DRL subsystem is formed using a capacitive coupling approach, too. An improvement of the acquisition system...
-
Extending touch-less interaction with smart glasses by implementing EMG module
PublicationIn this paper we propose to use temporal muscle contraction to perform certain actions. Method: The set of muscle contractions corresponding to one of three actions including “single-click”, “double-click” “click-n-hold” and “non-action” were recorded. After recording certain amount of signals, the set of five parameters was calculated. These parameters served as an input matrix for the neural network. Two-layer feedforward neural...
-
Open smart glasses development platform for AAL applications
PublicationThis paper describes an open platform for multi sensory electronic glasses that supports new and enhanced methods for intelligent interaction with patients, with smart objects, or to be used as new data input modalities like proximity sensor or smart textile interfaces. All the activities have been developed, investigated and evaluated within EU CHIST-ERA eGlasses project...
Year 2016
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublicationIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...
-
Cardiovascular data analysis using electronic wearable eyeglasses-preliminary study
Publicationhe paper presents an alternative approach to the monitoring of the cardiovascular system. The study depicts configurations of the utilized system and preliminary results of electrical and mechanical parameters of the cardiac system which can be measured using a head-worn device.
-
Detekcja osoby w wannie
PublicationStarzenie się społeczeństwa powoduje narastanie problemów chorób wieku starczego. Częstym problemem są zasłabnięcia w wannie podczas kąpieli. Celem publikacji jest przedstawienie metody identyfikacji tkanki ożywionej w wodzie z wykorzystaniem technik elektromagnetycznych. Obserwując zmiany amplitudy i częstotliwości pracy generatorów, pracujących w pętli sprzężenia zwrotnego z cewką, istnieje możliwość scharakteryzowania i określenia...
-
Detekcja osoby w wannie
PublicationStarzenie się społeczeństwa powoduje narastanie problemów chorób wieku starczego. Częstym problemem są zasłabnięcia w wannie podczas kąpieli. Celem publikacji jest przedstawienie metody identyfikacji tkanki ożywionej w wodzie z wykorzystaniem technik elektromagnetycznych. Obserwując zmiany amplitudy i częstotliwości pracy generatorów, pracujących w pętli sprzężenia zwrotnego z cewką, istnieje możliwość scharakteryzowania i określenia...
-
EMG and gaze based interaction with graphic interface of smart glasses application
PublicationIn this paper we investigate the effectiveness of the interaction using eye tracking and electromyography. Smart glasses requires reliable interfaces for controlling the graphic content displayed directly in front of the user's eye. Presented research is related with the eGlasses project, which is focused on the development of an open platform in the form of multisensory electronic glasses and related interaction methods. One of...
-
Enhanced Eye-Tracking Data: a Dual Sensor System for Smart Glasses Applications
PublicationA technique for the acquisition of an increased number of pupil positions, using a combined sensor consisting of a low-rate camera and a high-rate optical sensor, is presented in this paper. The additional data are provided by the optical movement-detection sensor mounted in close proximity to the eyeball. This proposed solution enables a significant increase in the number of registered fixation points and saccades and can be used...
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublicationRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Estimation of the amplitude of the signal for the active optical gesture sensor with sparse detectors
PublicationIn this paper we deal with the problem of precise gesture recognition for the active optical proximity sensor with sparse 8 photodiodes. We particularly focus on developing the method of estimating the real, usually not observable, maximum signal value representing maximum intensity of light reflected from an obstacle present in the front of the sensor. Different configurations of the fingers were used as an obstacle. The Monte Carlo...
-
Inteligentne otoczenie w aplikacjach prozdrowotnych - przykłady rozwiązań
PublicationW artykule przedstawiono koncepcję inteligentnego otoczenia jako wyposażenia tzw inteligentnego budynku ukieunkowanego na wspomaganie diagnostyki medycznej osób zagrożonych określonymi chorobami. Przedstawiono bliżej dwa rozwiązania – układ inteligentnej wagi i krzesła kardiologicznego.
-
Inteligentne otoczenie w aplikacjach prozdrowotnych - przykłady rozwiązań
PublicationW artykule przedstawiono koncepcję inteligentnego otoczenia jako wyposażenia tzw inteligentnego budynku ukieunkowanego na wspomaganie diagnostyki medycznej osób zagrożonych określonymi chorobami. Przedstawiono bliżej dwa rozwiązania – układ inteligentnej wagi i krzesła kardiologicznego.
-
Multichannel Human Body Communication
PublicationHuman Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog...
-
Performance Analysis of Interaction between Smart Glasses and Smart Objects Using Image-Based Object Identification
PublicationWe propose the use of smart glasses to collaborate with smart objects in the Internet of Things environment. Particularly we are focusing on new interaction methods and the analysis of acceptable reaction times in the process of object recognition using smart glasses. We evaluated the proposed method using user studies and experiments with three different smart glasses: Google Glass, Epson Moverio, and the developed eGlasses platform....
-
Self diagnostics using smart glasses - preliminary study
Publicationn this preliminary study we analyzed the possibility of the reliable measurement of biomedical signals with some potential hardware extensions of smart glasses. Using specially designed experimental prototypes four category of biomedical signals were measured: electrocardiograms, electromyograms, electroencephalograms and respiration waveforms. Experi- ments with volunteers proved that using even simple construc- tion of sensors...
seen 3547 times