Measurements of active power coefficients in a ship power station with two generators working in parallel
Description
The presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing active power coefficients in a ship power station.
The measurement setup is shown in Fig. 1. A measurement system based on NI PXIe-1062Q was used as a reference instrument for the E/A instrument performance assessment.
The dataset file was created on the base of the selected data derived from two files: E_A.txt (research data: Selected results of signal measurements in a ship power station with two generators working in parallel with the use of the Estimator/Analyzer instrument, R. Maśnicki D. Hallmann J. Mindykowski T. Tarasiuk M. Górniak M. Szweda, DOI:10.34808/dv88-sj58) and PXI.txt (research data: Selected results of measurements carried out in a ship power station with two generators working in parallel with the use of the NI PXIe-1062Q based measurement system, R. Maśnicki D. Hallmann J. Mindykowski T. Tarasiuk M. Górniak M. Szweda, DOI:10.34808/h2xb-8a23). Raw data from these files, after appropriate calculations and after time synchronization of the obtained results, were used to determine the parameters included in the file.
The individual rows of data contain the active power coefficient values designated with a time step of 200 ms using data obtained from the E/A instrument (PF1 E/A and PF2 E/A) as well as from the PXI system (PF1 PXI and PF2 PXI) during measurements in a ship power station with two operating generators G1 and G2. Since the active power E/A was calculated for the line voltages, and the active power PXI values were calculated using phase voltages, additional columns for power PXI values were added, corrected for the root of 3.
Fig. 1. The measurement setup
Dataset file
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
where a single part of the file is 512 MB in size.Example script for calculation:
https://github.com/antespi/s3md5
File details
- License:
-
open in new tabCC BYAttribution
Details
- Year of publication:
- 2020
- Verification date:
- 2020-12-17
- Creation date:
- 2011
- Dataset language:
- English
- Fields of science:
-
- Automation, electronic and electrical engineering (Engineering and Technology)
- DOI:
- DOI ID 10.34808/fw94-e021 open in new tab
- Verified by:
- Gdańsk University of Technology
Keywords
- measurement system
- ship power station
- assessment of metrological properties
- time synchronization
- active power coefficient
References
- dataset Selected results of measurements carried out in a ship power station with two generators working in parallel with the use of the NI PXIe-1062Q based measurement system
- dataset Selected results of signal measurements in a ship power station with two generators working in parallel with the use of the Estimator/Analyzer instrument