Description
The attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: plug flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated EC Electronics HSC 800 counter card. The sampling period was 1ms and this is the interval between the values in the attached files. A file ending in "1" contains data from the first probe, and a file ending in "2" contains data from the second probe.
The research installation was built at AGH University of Science and Technology in Kraków, Poland. The figure below shows the installation diagram. The measuring section of the 4.5 m long pipeline and 30 mm internal diameter was made of Metalplex. A detailed description of the set-up and tests of liquid-gas flow can be found in the publications available on the websites: https://www.sciencedirect.com/science/article/pii/S0955598617303667, https://www.sciencedirect.com/science/article/pii/S0301932215000233
Scheme of experimental hydraulic installation: 1 – gamma ray sealed source, 2 – scintillation probe; 3 – pipe; 4 – pump; 5 – compressor; 6 – air-removing container; 7 – air nozzle; 8 – shifting system of probes; 9 – ultrasonic flow meter
Dataset file
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
where a single part of the file is 512 MB in size.Example script for calculation:
https://github.com/antespi/s3md5
File details
- License:
-
open in new tabCC BYAttribution
Details
- Year of publication:
- 2020
- Verification date:
- 2020-12-17
- Creation date:
- 2017
- Dataset language:
- English
- Fields of science:
-
- Automation, electronic and electrical engineering (Engineering and Technology)
- environmental engineering, mining and energy (Engineering and Technology)
- DOI:
- DOI ID 10.34808/r506-nz78 open in new tab
- Verified by:
- Gdańsk University of Technology
Keywords
References
- dataset Two-phase water-air flow measurement using gamma-ray absorption technique – slug flow
- dataset Two-phase water-air flow measurement using gamma-ray absorption technique – transitional plug – bubble flow
- dataset Two-phase water-air flow measurement using gamma-ray absorption technique –bubble flow
Cite as
Authors
seen 166 times