Didn't find any results in this catalog!
But we have some results in other catalogs.Filters
total: 7121
displaying 1000 best results Help
Search results for: ARC WELDING FLUX-CORED WIRE STORAGE CONDITIONS WELDABILITY DIFUSIBLE HYDROGEN CONTENT
-
Diffusible Hydrogen Control in Flux Cored Arc Welding Process
PublicationOne of the types of hydrogen degradation of steel welded joints is cold cracking. The direct cause of the formation of cold cracks is simultaneous presence of hydrogen, residual stresses and brittle structure. The way of preventing the occurring of degradation is to eliminate at least one of these factors. Practice has shown that the best solution is to control the amount of hydrogen in deposited metal. In this paper an experimental...
-
Diffusible hydrogen management in underwater wet self-shielded flux cored arc welding
PublicationThis article reports the effect of underwater wet welding parameters and conditions on the diffusible hydrogen content in deposited metal for welding with a self-shielded flux cored wire. The diffusible hydrogen content in deposited metal was determined using the glycerin method according to the Plackett-Burman design determining the significance of the effect of the stick out length, welding current, arc voltage, travel speed...
-
Storage of High-Strength Steel Flux-Cored Welding Wires in Urbanized Areas
PublicationThe condition of the consumables is a key factor determining the waste reduction in the welding processes and the quality of the welded joint. The paper presents the results of tests of four types of fux-cored wires dedicated for welding high-strength steels, stored for 1 month and 6 months in Poland in two urbanized areas: in a large seaside city (Gdańsk) and in Warsaw, located in the center of the country. The wires were subjected...
-
Exploring the trends in flux-cored arc welding: scientometric analysis approach
PublicationFlux-cored arc welding (FCAW) is a universal group of welding methods in terms of the scope of application and automation possibilities, the share of which in various industries in many countries is still increasing. The paper presents the results of bibliographic analyses (scientometric analysis with the use of VOSviewer, Bibliometrix and CitNetExplorer tools) of a data set of 993 publications indexed in the Web of Science database...
-
Effects of Storing Flux-Cored Wires under Various Conditions
PublicationWelding processes involving the use of flux-cored wires are becoming increasingly popular, particularly in shipbuilding as well as in off-shore and civil engineering. The article presents characteristics of the welding process, its areas of application as well as advantages and disadvantages (e.g. necessity of ensuring appropriate conditions for the storage of filler metal wires). The satisfaction of quality-related requirements...
-
Preliminary studies of seamless flux cored wires stored in extreme conditions
PublicationIn the paper preliminary experimental studies of flux cored wires moisturized under controlled conditions are described. Three seamless wires of different grades have been placed in environmental chamber and moisturized in extremely adverse conditions (temperature T = 60° C, relative humidity H = 90%) for 240 hours. During this time measurements of weight gain and observations of surface of wires have been carried out. Also diffusible...
-
Plasticity of Bead-On-Plate Welds Made with the Use of Stored Flux-Cored Wires for Offshore Applications
PublicationExtreme atmospheric conditions in the marine and offshore industry are harmful to engineering materials, especially to welded joints, and may cause degradation of their properties. This article presents the results of research on the plasticity of bead-on-plate welds made using two types of seamless, copper plated flux-cored wires. Before welding, spools with wire were stored for 1 month in two distinct locations with different...
-
Assessment of absorbability of seamless flux cored wires stored in extreme conditions
PublicationWater absorption tests by gravimetric method of three specimens of seamless rutile flux cored wires for flux cored arc welding were carried out. Examined wires are characterized by varied absorbability (Wg is ranged from 0.03 to 0.11% after 200 h of moisturizing).
-
Effect of Storage Conditions of Rutile Flux Cored Welding Wires on Properties of Welds
PublicationThe influence of storage locations of two grades of rutile flux cored welding wires on their surface condition and the strength of the welds made with them were studied. Wires were stored in real urban conditions (Gdańsk and Katowice) for 1 month, simultaneously recording changes in conditions: temperature and relative humidity of the environment. Visual tests of wires in the delivered and stored condition as well as visual and...
-
The Effect of Welding Conditions on Mechanical Properties of Superduplex Stainless Steel Welded Joints
PublicationThe tests results of superduplex stainless steel welded joints made with a different heat input, using automatic submerged arc welding (SAW) and semi-automatic flux-cored arc welding (FCAW) have been presented. Metallographic examinations, the measurements of the ferrite content, the width of the heat affected zone (HAZ) and the hardness of the welds in characteristic areas have been performed. Significant differences in the amount of...