Didn't find any results in this catalog!
But we have some results in other catalogs.Filters
total: 48
Search results for: CONCRETE-FILLED FRP TUBE
-
Concrete-filled FRP tubular members in marine and bridge structures
PublicationConcrete core of the concrete-filled tubes (CFTs) with circular cross-section is in the case of an axial compression subjected to a spatial state of compressive stresses. This state leads to enhancement in the concrete strength. The enhancement is utilized in Eurocode 4 design procedures for CFSTs (i.e. CFTs with tube made of steel). The structural design of CFFTs (i.e. CFTs with tube made of Fibre Reinforced Polymer - FRP) is...
-
Efektywność skrępowania betonu w grubościennych słupach typu Concrete-Filled Steel Tube o przekroju kołowym
PublicationW słupach typu CFST w stanie granicznym dochodzi do zwiększenia wytrzymałości betonu rdzenia na skutek jego skrępowania. Zaistnienie tego zjawiska zależy od wielu czynników. Jednym z najważniejszych z nich jest sztywność obwodowa płaszcza stalowego. Jej wpływ na efektywność wzrostu wytrzymałości betonu rdzenia przebadano eksperymentalnie na grupie 48 grubościennych słupów CFST. Wykazano, że nadmierne zwiększanie grubości płaszcza...
-
The experimental research on the axially compressed CFFT columns
PublicationThe research objectives is to test the behaviour of the axially compressed glass fiber reinforced polymer tubes CFFT (concrete-filled FRP tube) withe the R-C core.
-
CFFT columns in road through railroad crossings
PublicationThere were 12801 road through railroad one-level crossings in Poland in 2018. 215 accidents happened at them in 2018. In order to increase safety in rail and road traffic two-level crossings should be used. They are definitely safer and make the traffic more smooth. In the design and construction of two-level intersections of railway and road or path columns of circular cross-section are often used. They can be successfully replaced...
-
Doraźna nośność słupów o przekroju kołowym z rur FRP wypełnionych betonem Badania, teoria, obliczanie
PublicationPraca ma charakter monografii opisującej aktualny stan wiedzy z zakresu badań, teorii i projektowania słupów CFFT (concrete-filled fiber-reinforced polymer tube). Celem prowadzonych przez autora prac studialnych i badań własnych, w tym eksperymentalnych, jest szczegółowa analiza doraźnej nośności i zachowania się słupów CFFT poddanych ściskaniu osiowemu i mimośrodowemu. W pierwszym rozdziale wyjaśniono motywację autora do podjęcia...
-
The use of GFRP tubes as load-bearing jackets in concrete-composite columns
PublicationThe paper presents the fields of applications of polymer composites in building structures. The use of composite glass fibre tubes is discussed in more detail. The laboratory methods used to test the mechanical properties of these pipes are presented. An original research program is presented, including six concrete-filled glass fibre tubes. The cylinders and columns made in this way were tested for their axial load capacity. Conclusions...
-
A Proposed Soft Computing Model for Ultimate Strength Estimation of FRP-Confined Concrete Cylinders
PublicationIn this paper, the feed-forward backpropagation neural network (FFBPNN) is used to propose a new formulation for predicting the compressive strength of fiber-reinforced polymer (FRP)-confined concrete cylinders. A set of experimental data has been considered in the analysis. The data include information about the dimensions of the concrete cylinders (diameter, length) and the total thickness of FRP layers, unconfined ultimate concrete...
-
Experimental Studies of Concrete-Filled Composite Tubes under Axial Short- and Long-Term Loads
PublicationThe paper presents experimental studies on axially compressed columns made of concrete-filled glass fiber reinforced polymer (GFRP) tubes. The infill concrete was C30/37 according to Eurocode 2. The investigated composite pipes were characterized by different angles of fiber winding in relation to the longitudinal axis of the element: 20, 55 and 85 degrees. Columns of two lengths, 0.4 m and 2.0 m, were studied. The internal diameter...
-
Load-carrying capacity of axially loaded concrete-filled steel tubular columns made of thin tubes
PublicationAn experimental investigation was conducted on 30 CFST columns. An influence of the following factors on load-carrying capacity of the investigated columns was analyzed: the column slenderness (l1 = 42, l2 = 27 and l3 = 15), the tube thickness (the reinforcement ratio was equal to 4% or 6%), the way of applying the load to CFST columns (through the concrete core or through the entire cross-section), the bond strength between a...
-
Flexural behaviour of concrete slabs reinforced with FRP bars in experiments and according to aci ACI 440.1R guide
PublicationThe paper presents research conducted on two concrete slabs reinforced with the carbon composite bars and two other concrete slabs reinforced with basalt composite bars. The carbon bars were plain, while the basalt ones were ribbed. The slabs were experimentally investigated in the flexural state of effort with the concentrated forces applied. The results are compared with the analytical solution proposed in the guide ACI 440.1R-06...