Filters
total: 3277
-
Catalog
displaying 1000 best results Help
Search results for: CURRENT COLLECTOR DIAGNOSTIC
-
3D scanning system for railway current collector contact strips
PublicationUndisturbed collection of current from a contact wire of the catenary constitutes one of the basic elements in reliable operation of electrified rail transport, particularly when vehicles move at high speed. Quality of current collection is influenced by the construction of catenary and current collectors, as well as by the technical condition and regulation of these two elements. Total contact force of a current collector head...
-
Wear estimation of current collector contact strips by analysis of a 3D scanning results
PublicationThe technical condition of current collector contact strips is very important when operational reliability of railway transportation is considered. The authors proposed a novel measurement system based on a 3D camera to register the shape and dimensions of the current collector contact strips surface. The system was installed above the railway track for tests in target ambient. During the trial operation a few dozen of contact...
-
A new approach to determination of the two-mass model parameters of railway current collector
PublicationThe paper presents two mathematical models of railway current collectors both with two degrees of freedom. The first one, hereinafter Pantograph Articulated Model (PAM), has one degree of freedom in rotational motion and the second degree of freedom in translational motion. The second model, called henceforth as Pantograph Reference Model (PRM), has both degrees of freedom in translational motion. Differential equations of the...
-
A new approach to determination of the two-mass model parameters of railway current collector
PublicationThe paper presents two mathematical models of railway current collectors both with two degrees of freedom. The first one, hereinafter Pantograph Articulated Model (PAM), has one degree of freedom in rotational motion and the second degree of freedom in translational motion. The second model, called henceforth as Pantograph Reference Model (PRM), has both degrees of freedom in translational motion. Differential equations of the...
-
Measurements and Analysis of Motor Supplying Current Waveform for Diagnostic Purposes
PublicationPodano proponowaną metodę diagnostyki łożysk tocznych w silnikach indukcyjnych poprzez pomiar i analizę prądu zasilającego. Przedstawiono opracowany system pomiarowy oraz wyniki badań na łożyskach o specjalnie wprowadzonych uszkodzeniach.
-
Measuring system for analysis of motor supplying current for diagnostic purposes
PublicationProblemy, jakie pojawiają się przy interpretacji wyników pomiarów prądu silnika dla celów diagnostycznych wynikają z różnicy częstotliwości składowych obliczonych teoretycznie i uzyskanych w badaniach eksperymentalnych. W przedstawionym systemie pomiarowym problem ten rozwiązano w ten sposób, że pomiar częstotliwości sieci zasilającej i prędkości obrotowej jest wykonywany w tym samym przedziale czasowym, co pomiar składowych widma.
-
Current Problems in Diagnostic Radiology
Journals -
Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor
PublicationDiagnosis of induction motors, conducted remotely by measuring and analyzing the supply current is attractive with the lack of access to the engine. So far there is no solution, based on analysis of current, the credibility of which allow use in industry. Statistics of IM bearing failures of induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is so important. The article provides...
-
Current-based higher-order spectral covariance as a bearing diagnostic feature for induction motors
PublicationConducting the diagnosis of induction motors remotely by analyzing the supply current is an attractive prospect with the lack of access to the engine. Currently, there is no solution, based on analysis of the current, the credibility of which would allow its use in industry. The statistics of bearing failures in induction motors indicate that they constitute more than 40% of induction motor damage, therefore, bearing diagnosis...
-
Comparison of induction motor bearing diagnostic test results through vibration and stator current measurement
PublicationThe paper discusses results of tests performed by authors, related to the angine bearings diagnostic using vibration and stator current measurements. The paper contains the description of an automatic measurement system, developed for measurement of those harmonics and processing that to obtain bearing diagnostic information. System was tested on objects with intentionally made defects in bearings, results of this test was also...
-
Crossroad between current knowledge and new perspective of diagnostic and therapy of late-onset schizophrenia and very late-onset schizophrenia-like psychosis: An update
Publication -
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublicationRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Experimental verification of visual method for measuring displacements of contact line elements
PublicationThe increase of rail vehicles speed, as well as the increase of their power, puts high demands on the power delivery system for traction vehicles The most critical point in the vehicle's power supply circuit is the contact between the current collector and contact wires. Ensuring a reliable co-operation of the current collector and contact line, requires technical development...
-
The new version of contact-less method for localisation of catenary contact wire – theoretical assumption
PublicationThis article presents the theoretical basic of a new version of contact-less method for localising the catenary contact wires, using the advanced video techniques and image analysis. So far, contact line diagnostic systems exploited nowadays uses the contact measuring methods with special design current collector. This solutions make it impossible to measure the contact line geometry in a static way. The proposed measurement method...
-
Analysis of measurement uncertainty for contact-less method used to measure the position of catenary contact wire, performed with the use of Monte Carlo method
PublicationCurrently the majority of main railway lines in Europe are electrified, and electric trains have the biggest share in the entire amount of rail transport. Reliability of electrified railways is closely related to the issue of supplying traction vehicles with energy. The problems connected with diagnostics of energy consumption node, namely the contact line and the current collector, are therefore of fundamental importance for maintaining...
-
Nowa metoda diagnostyki stanu technicznego nakładek stykowych
PublicationThe current collection system, which consists of the overhead contact line and a current collector, is particularly important in electric rail vehicles, where their reliability is concerned. Faultless current collection is conditioned not only by suitable construction of these elements but also by their proper maintenance. Retaining permanent electrical contact is essential in DC systems, where current demand is relatively high. In...
-
Modelowanie dynamiki odbieraka prądu pojazdu kolejowego do celów diagnostycznych
PublicationNiewłaściwa współpraca odbieraka prądu i sieci trakcyjnej, w trudnych warunkach lokalnych, może prowadzić do uszkodzenia sieci trakcyjnej i pantografu. W ramach rozwoju metod monitoringu i diagnostyki dla tych podsystemów, tworzone są nowe i dokładniejsze narzędzia symulacyjne, których zakres obejmuje modelowanie zarówno napowietrznej sieci trakcyjnej i pantografu, a także ich dynamicznego oddziaływania. Głównym celem jest dokładniejsza...
-
Wybrane aspekty modelowania matematycznego kolejowego odbieraka prądu
PublicationNieprawidłowa współpraca odbieraka z siecią jezdną, w niekorzystnych warunkach lokalnych, prowadzi do uszkodzeń sieci lub odbieraka. Może być to spowodowane niewłaściwym wykonaniem lub utrzymaniem tych istotnych elementów układu zasilania. Tego typu sytuacje awaryjne powodują duże opóźnienia w ruchu pociągów i generują olbrzymie koszty. Wskazuje to na duże znaczenie odpowiednich rozwiązań konstrukcyjnych sieci i odbieraków oraz...
-
Koncepcja zdalnego sterowania i monitoringu urządzeń trakcyjnych z wykorzystaniem technologii teleinformatycznych
PublicationAdvancement in wireless communication enables engineers to apply sophisticated and relatively inexpensive technologies in new fields of industry, which were previously designated solely to wire-based solutions. One of those fields is railway transportation system. In effect of a high reliability and safety demands, this area was resistive to new technologies. Nowadays, increased security and reliability of wireless sensor networks...
-
Wizyjny system monitoringu stanu nakładek stykowych odbieraków prądu
PublicationEksploatowane do niedawna w Polsce nakładki pantografów kolejowych były wykonywane w postaci styków miedzianych. Na początku 2011 r. przeprowadzono kompleksową zmianę typu nakładek stykowych, stosowanych przez operatorów korzystających z infrastruktury PKP PLK S.A., z miedzianych na metalizowane węglowe. Wraz z wprowadzeniem nakładek węglowych istnieje potrzeba opracowania nowych metod diagnostyki tego istotnego elementu toru zasilania...