Analysis of radiometric signal in sedimentating suspension flow in open channel
PublicationThe article discusses issues related to the estimation of the sedimentating solid particles average flow velocity in an open channel using radiometric methods. Due to the composition of the compound, which formed water and diatomite, received data have a very weak signal to noise ratio. In the process analysis the known determining of the solid phase transportation time delay the classical cross-correlation function is the most...
-
Analysis and interpretation of radiometric signals in a liquid-gas bubble flow
PublicationThe article presents the analysis of signals from a radiometric system consisting of two scintillation probes and two gamma radiation sealed sources. Calculations and interpretation were carried out for the bubble flow of the water-air mixture in the horizontal pipeline. The analysis of the obtained signals was done in time and frequency domain. In the frequency domain, a range of usable frequencies was identified, which were associated...
-
Comparison of noise reduction methods in radiometric correlation measurements of two-phase liquid-gas flows
PublicationTwo-phase liquid-gas flows occur frequently in the mining, energy, chemical, and petrochemical industries. One of non-contact methods used to analyse these flows is the gamma ray absorption method. However, the signals received from radiation detectors contain a significant stochastic noise, which makes them difficult to analyse. The article describes four methods of noise reduction in cross-correlation measurements of water-air...
-
MINIATURA Research internship at the National Technical University of Athens on the study of geometric and radiometric calibration methods for multi-camera remote sensing systems under artificial illumination
ProjectsProject realized in Gdańsk University of Technology according to 2022/06/X/ST10/00114 agreement from 2022-06-23
-
NUTA RI Research internship at the National Technical University of Athens on the study of geometric and radiometric calibration methods for multi-camera remote sensing systems under artificial illumination.
ProjectsProject realized in Department of Geodesy
-
Metoda bezkontaktowego wielopasmowego pomiaru emisyjności.**2003, 100 s.30 rys. 6 tab. bibliogr. 86 poz. maszyn. Rozprawa doktorska /01.07.2003/ Wydz. ETI Promotor: prof. zw. dr hab. inż. K. Chrzanowski
PublicationW pracy omówiona została metoda bezkontaktowego wielopasmowego pomiaru emi-syjności. Przedstawiona została ogólna koncepcja systemu pomiarowego do bez-kontaktowych pomiarów emisyjności, a także opracowany został matematyczny o-pis elementów systemu. Dla wyznaczenia nieznanych wartości temperatury i e-misyjności obiektu na podstawie zgromadzonych danych pomiarowych wykorzysta-na została aproksymacja za pomocą liniowej metody najmniejszych...
-
Experimental verification of multiband system of non coantact temperature measurements. IV Workshop on Atomic and Molecular Physics.
PublicationW pracy przedstawiono wielopasmowy optoelektroniczny system do bezkontaktowych pomiarów temperatury wykonane za jego pomocą w zakresie od 250 do 390 stopni Celsjusza. Przeprowadzono dyskusję błędów pomiarowych i porównano otrzymane rezultaty z wynikami modelowania komputerowego.
-
Non contact multiband method for emissivity measurment.
PublicationW pracy omówiona została metoda bezkontaktowego wielopasmowgo pomiaru emisyjności. W oparciu o opracowany algorytm zbadany został wpływ poszczególnych elementów systemu i czynników zakłócających na dokładność wyznaczania emisyjności. Wyniki modelowania umożliwiają także ocenę dokładności całego systemu pomiarowego.