dr hab. inż. Adam Kloskowski
Zatrudnienie
- Profesor uczelni w Katedra Chemii Fizycznej
Publikacje
Filtry
wszystkich: 69
Katalog Publikacji
Rok 2019
-
Analytical applications and physicochemical properties of ionic liquid-based hybrid materials: A review
PublikacjaIonic liquids with their unique properties found so far numerous analytical applications. Among them ionic liquids immobilized on the surface or within the pores of a solid support were successfully utilized in extraction techniques dedicated to preconcentration of the analytes from food, environmental and biological samples. In this review we focus on comprehensive summarizing of available literature data on the examples of ionic...
-
Application of ionic liquids in microextraction techniques: Current trends and future perspectives
PublikacjaIonic liquids (ILs) with their unique properties found so far numerous analytical applications. Among them ILs both in their liquid form and immobilized on the surface or within the pores of a solid support were successfully utilized in microextraction techniques. The scope of this review will cover a comprehensive summarizing of available literature data on selected properties of ILs playing a key role in analytical purposes,...
-
Ciecze jonowe jako medium sorpcyjne w mikroekstrakcji do pojedynczej kropli Cz. I. Podstawy teoretyczne zagadnienia
PublikacjaTechnika mikroekstrakcji do pojedynczej kropli stanowi sztandarowy przykład rozwiązania technicznego spełniającego wymogi stawiane przez ideę zielonej chemii analitycznej.
-
Ciecze jonowe jako medium sorpcyjne w mikroekstrakcji do pojedynczej kropli. Cz.II. Praktyka analityczna
PublikacjaPomimo rosnącego zainteresowania metodami analitycznymi opartymi na użyciu cieczy jonowych ich sprzężenie wraz z techniką mikroekstrakcji do pojedynczej kropli nie osiągnęło zadowalającej popularności oraz akceptacji ze strony środowiska naukowego.
-
Density, sound velocity, viscosity, and refractive index of new morpholinium ionic liquids with amino acid-based anions: Effect of temperature, alkyl chain length, and anion
PublikacjaIn this work, room temperature synthesis of twenty new ionic liquids (ILs) based on the N-alkyl-N-methylmorpholinium ([Mor1,R], R = 2, 3, 4, 6, 8) cation and N-acetyl-L-amino acid anions (L-alaninate, L-valinate, L-leucinate, L-isoleucinate) was described. The synthesized ILs were characterized by various spectroscopic techniques and high-resolution mass spectrometry. Furthermore, density (ρ), sound velocity (v), viscosity (η)...
Rok 2014
-
Apparent Molar Volumes and Expansivities of Ionic Liquids Based on N-Alkyl-N-methylmorpholinium Cations in Acetonitrile
PublikacjaDensities of some acetonitrile solutions of ionic liquids based on N-alkyl-N-methyl-morpholinium cations, N-ethyl-N-methylmorpholinium bis(trifluoromethanesulfonyl)imide, N-butyl-N-methylmorpholinium bis(trifluoromethanesulfonyl)imide, N-methyl-N-octylmorpholinium bis(trifluoromethanesulfonyl)imide and N-decyl-N-methylmorpholinium bis(trifluoromethanesulfonyl)imide were measured at T = (298.15− 318.15) K and at atmospheric pressure....
Rok 2016
-
Application of Ionic Liquids in Amperometric Gas Sensors
PublikacjaThis article presents an analysis of available literature data on metrological parameters of the amperometric gas sensors containing ionic liquids as an electrolyte. Four mechanism types of signal generation in amperometric sensors with ionic liquid are described. Moreover, this article describes the influence of selected physico-chemical properties of the ionic liquids on the metrological parameters of these sensors. Some metrological...
-
Ciecze jonowe w technikach mikroekstrakcyjnych - cz. I. Struktura i właściwości fizykochemiczne
PublikacjaCiecze jonowe stanowią bradzo rozbudowaną grupę substancji, cechującą się ogromnym potencjałem zastosowania w różnych dziedzinach chemii.
-
Ciecze jonowe w technikach mikroekstrakcyjnych. Cz. II. Praktyka analityczna.
PublikacjaRosnące od lat zainteresowanie cieczami jonowymi, wynikające z ich unikalnych właściwości fizykochemicznych, znalazło odzwierciedlenie w ich wykorzystaniu jako rozpuszczalników w chemii analitycznej, w tym szczególnie w wielu technikach przygotowania próbek do analizy. Ciecze jonowe zastosowano jako materiał sorpcyjny w takich technikach jak: mikroekstrakcja do fazy stacjonarnej SPME; mikroekstrakcja do pojedynczej kropli, SDME...
Rok 2004
-
Automated high-capacity sorption probe for extraction of organic compounds in aqueous samples followed by gas chromatographic analysis.
PublikacjaOpracowano zautomatyzowany zestaw wyposażony w próbnik o dużej pojemności sorpcyjnej do oznaczania związków śladowych z zastosowaniem chromatografii gazowej. Zestaw łączy prostotę SPME z wysoką wydajnością techniki ekstrakcji z zastosowaniem ruchomego elementu sorpcyjnego (SBSE). Procedura pobierania próbek była przeprowadzana z zastosowaniem podajnika automatycznego. Ze względu na pełną automatyzację zestawu, możliwa jest bezobsługowa...
Rok 2017
-
Characteristic of Morpholinium Ionic Liquids as Gas Chromatography Stationary Phases with McReynolds Constants and Activity Coefficients at Infinite Dilution
PublikacjaIn this work, four ionic liquids based on N-alkyl-N-methylmorpholinium cation ([Mor1,R] where R= 2, 4, 8, 10) and bis(trifluoromethanesulfonyl)imide anion [TFSI] were synthesized. Using gas-liquid chromatography a number of parameters describing the sorption properties of the investigated ionic liquids were determined. The values of Kovats indices, McReynolds constants, and activity coefficients at infinite dilution were the basis...
Rok 2010
-
Current trends in solid-phase microextraction (SPME) fibre catings
PublikacjaThis critical review presents information on known and innovative approaches to the manufacture of fibre coatings used in solid-phase microextraction (SPME). The properties, advantages and drawbacks of the different types of commercially available SPME fibre coatings are discussed in detail, as are those of novel types of coatings and the methodologies of their preparation. The applications of fibre coatings in the solid-phase...
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublikacjaPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
Rok 2002
-
Denudation - a convenient method of isolation and enrichment of analytes
PublikacjaW pracy przedstawiono: podstawy teoretyczne techniki denudacyjnej; rozwiązania konstrukcyjne podstawowych typów urządzeń denudacyjnych; obszar praktycznego wykorzystania technik denudacyjnych.
Rok 2013
-
Determination of volatile organic compounds in water samples using membrane-solid phase microextraction (M-SPME) (headspace version)
PublikacjaThe results of a study on the use of membrane-solid phase microextraction (M-SPME) for sampling volatile organic compounds (VOCs) from the headspace above the liquid medium are presented. The sampled VOCs were subsequently quantified by gas chromatography (GC). Two systems were compared in this study, i.e. a novel two-phase sorption system (M-SPME), and a commercial fibre. Headspace sampling using SPME was optimized with respect...
Rok 2022
-
Development of SPME fiber coatings with tunable porosity for physical confinement of ionic liquids as an extraction media
PublikacjaExtending the use of ionic liquids in sample preparation techniques remains a challenge. This paper presents procedures enabling the easy application of ionic liquids to the SPME technique. For this purpose, two approaches for producing a porous silica coating on a metal rod were investigated. Two silica precursor and porogen systems were used in the research: K2SiO3 + Formamide and Tetramethyl-orthosilicate + Polyethylene oxide....
Rok 2011
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublikacjaThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
Rok 2012
-
Elektrochemiczny czujnik na bazie cieczy jonowej do oznaczania par benzaldehydu
PublikacjaW pracy przedstawiono prototypowy, laboratoryjny, elektrochemiczny czujnik do oznaczania par benzaldehydu w argonie. Cieczą jonową testowaną jako elektrolit i środowisko reakcji redox była: bis(trifluorometylosulfonylo)imidek 1-butylo,3-metyloimidazolinowy ([BMIM][Tf2N]). W pomiarach użyto komercyjnych elektrod firm: DropSens Co. i BVT Technologies. Walidacji poddano dwa parametry metrologiczne czujnika: granicę wykrywalności i...
-
Elektrochemiczny gazowy czujnik na bazie cieczy jonowej do oznaczania benzaldehydu
PublikacjaW pracy przedstawiono wyniki badań dotyczące opracowania dwóch wersji prototypowego, laboratoryjnego elektrochemicznego czujnika do oznaczania par benzaldehydu. Elektrolitem w tych czujnikach była ciecz jonowa [HMIM][Tf2N] (bis(trifluorometylosulfonylo)imidek 1-heksylo,3-metyloimidazolinowy). Jeden z czujników zbudowany był wg koncepcji Clarka z membraną PDMS, drugi z użyciem komercyjnych elektrod firmy DropSens Co. W obu wersjach,...
wyświetlono 2243 razy