dr inż. Agata Jażdżewska
Zatrudnienie
Publikacje
Filtry
wszystkich: 29
Katalog Publikacji
Rok 2023
-
Effect of wet Hydrogen Sulfide on Carbon Steels Degradation in Refinery Based on Case Study
PublikacjaMaterial degradation caused by wet hydrogen sulfide (Wet H2S) is one of the major issues in refineries. Carbon steel is the main construction material used in refineries and is subjected not only to thickness loss but the hydrogen is the major concern. H2S leads to high atomic hydrogen penetration in steel which causes degradation in the form of blistering and/or cracking (HIC/SOHIC) and stress cracking in the area of welds and...
Rok 2020
-
DETERMINATION OF THE EFFECT OF ENVIRONMENTAL FACTORS ON THE CORROSION OF WATER DISTRIBUTION SYSTEM BASED ON ANALYSIS OF ON-LINE CORROSION MONITORING RESULTS
PublikacjaCorrosion of water distribution system is a significant issue causing problems with quality, safety and continuity of distribution. The changes of corrosion rates of the water distribution systems in Cracow made of carbon steel were investigated by analysis of online corrosion monitoring system results. Corrosion rates were determined using the linear polarization method. The impact of rain, temperatures, conductivity, dissolved...
-
RESEARCH ON ORGANIC COATINGS DESIGNED FOR UNDERWATER APPLICATIONS
PublikacjaUnderwater steel structures require periodic maintenance. In the case of vessels, anti-corrosion works are carried out in the shipyard, where very good conditions for applying organic protective coatings can be provided. Very good surface preparation can be obtained by the use of abrasive blasting. The well-prepared metal surface is free from impurities (particularly inorganic salts). Suitable conditions for the application and...
Rok 2018
-
Complex Corrosion Monitoring System for Crude Distillation Unit in Form of Neutral Network
PublikacjaComplex and successful corrosion monitoring of refinery processes can significantly reduce material losses and failure risk. The developed corrosion monitoring system is based on online ultrasonic sensors, ER (electrical resistance) probes, gravimetric method and multipoint analytical analysis of chemical composition of the fluids. Additional online LPR (linear polarization resistance) sensors controlling corrosiveness of sour...
-
Development of dynamic method for evaluation of inhibition efficiency on the example of 8-hydroxyquinolin
PublikacjaSelection of a proper inhibitor should be based on the evaluation of its mechanism and effective concentrations. Mechanism of inhibition usually has dynamic character due to changing physicochemical conditions of the environment and corroding metal surface. Most of actually used methods are stationary or contain assumptions which highly influences obtained values. Development of new dynamic method, based on modified EIS, allows...
-
Metal dusting phenomena of 501 AISI furnace tubes in refinery fractional distillation unit
PublikacjaThe purpose of this investigation was to conduct the failure analysis of 501 AISI furnace tubes places before distillation column in fractional distillation unit. The investigated furnace tubes were planned to work for ten years however after just two years of exploitation <30% of the material left. The observed corrosion process had the intense and complex character. The well-adhered shiny black deposits and deep, round pits were...
Rok 2017
-
Badania skuteczności ochrony katodowej nóg platformy wydobywczej
PublikacjaWykonano badania potencjałowe parametrów ochrony platformy wydobywczej Baltic Beta. Stwierdzono występowanie pełnej ochrony katodowej w rejonie dna. Stan techniczny anod wykazuje znaczne zużycie, jednakże w dalszym ciągu realizują proces ochorny
-
Comprehensive study on graphene hydrogels and aerogels synthesis and their ability of gold nanoparticles adsorption
PublikacjaGraphene hydrogels were prepared by ascorbic acid-assisted gelation of graphene oxide (GO) aqueous suspensions both in acidic and basic conditions. Different mass ratio of ascorbic acid (AA) to GO was used (namely 20:1 and 10:1). In order to eliminate the influence of AA on the final structure of hydrogels, samples without AA were prepared by a hydrothermal gelation of GO in an autoclave. An in-depth structural characterization...
-
Corrosion behavior of concrete produced with diatomite and zeolite exposed to chlorides
PublikacjaChloride induced reinforcement corrosion is widely accepted to be the most frequent mechanism causing premature degradation of reinforced concrete structures. The electrochemical impedance of reinforcing steel in diatomite- and zeolite-containing concrete exposed to sodium chloride was assessed. Chemical, physical and mineralogical properties of three concrete samples (20% diatomite, 20% zeolite, and a reference containing neither)...
-
Determination of pitting corrosion stage of stainless steel by galvanodynamic impedance spectroscopy
PublikacjaThis paper investigates the methodology for differentiation of multistep process of pitting corrosion of AISI 304 stainless steel in the environment of iron (III) chloride. Measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Application of this methodology allowed monitoring of natural corrosion process without external current (IDC = 0A) nor potential perturbation of the system. Applied...
-
Impedancyjne monitorowanie szybkości korozji w układach wodnych z zastosowaniem inhibitorów korozji
PublikacjaNiniejsza praca jest poświęcona opracowaniu metodyki pomiarowej pozwalającej na wyznaczanie szybkości korozji za pomocą metody galwanodynamicznej elektrochemicznej spektroskopii impedancyjnej (GDEIS). Zaproponowana metoda pozwala na wykonywanie badań korozyjnych w których klasyczne metody pomiarowe (polaryzacja liniowa, metoda EIS, polaryzacja Tafela) charakteryzują się otrzymywaniem wyników ze znaczną dozą niepewności. W przypadku...
-
Monitorowanie szybkości korozji oraz dobór materiałów konstrukcyjnych w instalacji wody morskiej platformy Baltic Beta
PublikacjaWykonano analizę szybkości korozji systemu monitorowania korozji z okresu od 25.11.2016 do 12.07.2017. Zdemontowano czujnik korozyjny w instalacji wody morskiej, Zainstalowani nowy czujnik z opcją pomiaru szybkości korozji metodą kuponową. Monitoringiem poddano następujące materiały: 1.7362, 1.5415, 1.0038
-
Wyjaśnienie przyczyn korozji rur kotła, wytwornicy pary technologicznej instalacji Olefiny
PublikacjaWykonano badania przyczyn korozji rurek wytwornicy pary instalacji Olefiny. Przeprowadzono badania metalograficzne oraz SEM i EDX produktów korozji
-
Wykonanie czujnika LPR oraz dobór materiałów konstrukcyjnych w instalacji wody morskiej
PublikacjaWykonano analizę pracy systemu monitorowania korozji, dokonano wymiany czujnika. Zamontowano nowy czujnik z opcją pomiaru kuponowego w celu doboru materiałów konstrukcyjnych do instalacji wody morskiej.
Rok 2016
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublikacjaCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...
-
Development Of Dynamic Method For Evaluation Of Corrosion Rate On The Example Of Organic Corrosion İnhibitor
PublikacjaMeasurements of the corrosion rate belong to the most important aspects of materials science. In order to reduce material loss corrosion inhibitors are used. However selection of proper inhibitor should be based on evaluation of its mechanism and effective concentrations. Mechanism of inhibition usually has dynamic character so physicochemical parameters are changing in time. Most of actually used methods...
-
Effect of Thermal Shock During Legionella Bacteria Removal on the Corrosion Properties of Zinc-Coated Steel Pipes
PublikacjaThe purpose of this investigation was to conduct the failure analysis of a water-supply system made from zinc-coated steel. The observed corrosion process had an intense and complex character. The brownish deposits and perforations were present after 2-3 years of exploitation. The electrochemical study based on the Tafel polarization, corrosion potential monitoring, and electrochemical impedance spectroscopy together with microscopic...
-
Ekspertyza stanu technicznego zbiorników wysłodzin
PublikacjaCelem pracy było określenie stanu technicznego czterech zbiorników wysłodzin na terenie Browaru Elbląg. Zbiorniki oddane zostały do użytku w 1984 roku i zostały wykonane ze stali niestopowej konstrukcyjnej. Ekspertyza została wykonana na podstawie badań ultradźwiękowych grubości stali zbiornika, głębokości wżerów, magnetycznym pomiarze grubości powłoki malarskiej, pomiarze potencjałów stali względem elektrody siarczano-cynkowej...
-
Electrolytic corrosion of water pipeline system in the remote distance from stray currents– case study
PublikacjaCase study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800 ÷ 1,000 meters from the point of failure. At the point of failure stray currents flowed from the pipeline...
-
Opracowanie systemu monitorowania korozji instalacji podstawowej Alkilacji HF w celu bieżącej oceny zagrożenia korozyjnego instalacji
PublikacjaWykonano analizę stanu zagrożenia korozyjnego instalacji alkilacji HF w PKN Orlen S.A. Wytypowano miejsca które powinny zostać objęte systemem monitorowania korozji. Zaprojektowano śluzę korozyjną. Dokonano oceny merytorycznej oraz finansowej różnych rozwiązań systemów monitorowania korozji
-
Research on causes of corrosion in the municipal water supply system
PublikacjaThis paper presents results of failure analysis study to characterize the corrosion damage that occurred in the water supply system in Krakow. This analysis includes: electrochemical noise, linear polarization and resistometric measurements. Water aggressiveness of four water intakes was defined using Langelier and Ryznar indices. Results from this indices did not reveal the causes of considerable corrosion losses in water systems....
-
System pomiaru szybkości korozji metodą polaryzacji liniowej w zbiorniku zatłaczającym wodę złożową oraz systemu wody morskiej na platformie wydobywczej Baltic Beta
PublikacjaWykonano analizę sprawności systemu monitorowania szybkości korozji na Platformie wydobywczej Baltic Beta. Dokonano niezbędnych czynności, które umożliwiły ponowne uruchomienie systemu. Przedstawiono rejestry szybkości korozji w okresie od 01.01.2015 do 24.11.2016
-
Wyjaśnienie przyczyn pocienienia rur w piecu technologicznym PC-1 na instalacji DRW II
PublikacjaWykonano analizę przyczyn korozji rur pieca instalacji DRW w oparciu o badania wizualne, SEM, EDX oraz literaturowe. W ciągu 5 lat eksploatacji nastąpiły znaczne ubytki korozyjne rur w wyniku procesów korozyjnych. Z uwagi na zbyt wysoką temperaturę rurek pieca nastąpił proces wysokotemperaturowego pylenia metalu.
Rok 2015
-
A comprehensive evaluation of mimosa extract as a corrosion inhibitor on AA6060 alloy in acid rain solution: part I. Electrochemical AC methods
PublikacjaThe inhibition effect of mimosa extract on the corrosion of AA6060 aluminum alloy in acid rain solution was investigated by electrochemical impedance spectroscopy and dynamic electrochemical impedance spectroscopy (DEIS). All the studied electrochemical parameters showed good corrosion inhibitive characteristics with respect to the aluminum alloy in the tested solution. Inhibitor efficiency increased with the concentration and...
-
The Effect of Cryogenic Treatment on Microstructure and Mechanical Response of AISI D3 Tool Steel Punches
PublikacjaRecently, deep cryogenic treatment is performed to improve the mechanical responses (wear, hardness, fatigue, and thermal conductivity) of various steel components. Researchers have tried to evaluate the eco-friendly and nontoxic process to optimize the parameters. Cold-shearing punches used to manufacture various holes that undergo severe impact loading and wear in the metal forming process. This study concerns the effect of soaking...
-
The protection and monitoring of a distribution piping network for potable water supply
PublikacjaPurpose – The purpose of this paper is to implement the corrosion protection method for steel pipes used in a municipal water-pipe network. Results of an inhibitor protection system installed on the system are presented. Inhibitor protection was required due to the high corrosivity of the water collected by a surface intake, which had resulted in a large number of failures and low water quality, due to the presence of corrosion...
Rok 2014
-
Analiza weryfikująca poprawność istniejącego układu ochrony przed korozją i osadami instalacji DRW4 w kontekście obecnych warunków pracy instalacji
PublikacjaCelem pracy były pomiary korozyjności kondensatów pochodzących z kolumny destylacyjnej z dodatkiem neutralizatora oraz inhibitora korozji, ponadto przeprowadzono badania SEM i EDX produktów korozji pochodzących z rurek chłodnicy powietrznej. Wykazano, że znacznie większą agresywnością charakteryzują się kondensaty które pochodzą z przerobu ropy naftowej zawierającą slopy.
-
Simultaneous impedance and volumetric studies and additionally potentiodynamic polarization measurements of molasses as a carbon steel corrosion inhibitor in 1M hydrochloric acid solution
PublikacjaThe inhibition effect of molasses on the corrosion of low carbon steel in 1M hydrochloric acid solution was investigated by volumetric and electrochemical measurements. Potentiodynamic polarization and dynamic electrochemical impedance spectroscopy (DEIS) results were obtained and compared with to those, obtained with the hydrogen evolution technique. All results indicate that molasses functioned as a good inhibitor in 1M hydrochloric...
Rok 2013
-
Electrochemical investigations on the corrosion behaviour of reinforcing steel in diatomite- and zeolite-containing concrete exposed to sulphuric acid
PublikacjaCorrosion is a major concern for most structural applications. Its detrimental effect significantly reduces the life of metallic components. This paper presents the results of an experimental investigation of corrosion in the steel reinforcement of concrete samples having three different substituents: 20% diatomite, 20% zeolite, and a reference without zeolite or diatomite. All concrete specimens were subjected to a solution of...
wyświetlono 1475 razy