The harmonic distortion of voltage waveforms in the ship's electrical power system - Open Research Data - MOST Wiedzy

Wyszukiwarka

The harmonic distortion of voltage waveforms in the ship's electrical power system

Opis

The dataset is a part of the research results on the quality of supply voltage on bus bars of the ship's electrical power system's main switchboard in different states of ship exploitation. The attached dataset contains the results of a harmonic distortion analysis expressed by the total harmonic distortion (THD) coefficient of voltage waveforms recorded during measurements. The measurements were carried out onboard various ships: ferry, ro-ro, and car -carrier.

Each ship contains a three-phase, three-wire electrical power system. The ferry and ro-ro systems' electrical power plant consists of free-standing generating sets and shaft generators. The source of electrical power is three-phase synchronous generators driven by auxiliary diesel engines. Additionally, shaft generators driven by the propeller shaft of the main engine are used. The ferry’s electrical power plant consists of three free-standing generators of 1400 kVA each, and two shaft generators of 1375 kVA each. The main switchboard's nominal voltage on the bus bars was 380 V with a frequency equal to 50 Hz. The ferry was equipped with two free-standing generators of 1000 kVA each and two shaft generators of 1500 kVA. The nominal voltage on the main switchboard's bus bars was 400 V at a frequency of 50 Hz. The car carrier’s electrical power plant consists of six free-standing generators of 1500 kVA each. The main switchboard's nominal voltage on bus bars was 3300 V and 440 V with a frequency equal to 60 Hz. All ships were capable of generating the voltage of 220V, and after transformation – 440V, 400V, and 380V.

The voltage waveforms on the main switchboard's bus bars were recorded with the digital measuring system, which allows the simultaneous measurement of three phase-to-phase or two-phase voltages. Its hardware part consists of a signal preconditioning block, an antialiasing filter, and a data acquisition board with a resolution of 16 bits and a sampling rate of up to 20 kS/s. The maximum sampling rate is equal to 6.6 kS/s for using three channels at the same time. The virtual part of the system is realized in the graphical programming environment LabVIEW. The THD is calculated as the equivalent root mean square (rms) voltage of a set of the harmonic frequencies (from the 2nd harmonic on to 40th harmonics) over the rms voltage of the fundamental frequency. The data were multiplied by the Hann window function. The frequency analysis was made using a fast Fourier transform (FFT) for the time frame of 2048 samples. The calculated Fourier transforms components were averaged 10 times. The final THD value was obtained based on the instantaneous values averaged over 40 minutes of the observation time.

 

Ilustracja publikacji

where:

Uh - the rms voltage of the h-th harmonics

 U1 - the rms voltage of the fundamental frequency

Plik z danymi badawczymi

THD.xls
252.0 kB, S3 ETag a2ce16e17b3f3ee213111c3d57b01d29-1, pobrań: 33
Hash pliku liczony jest ze wzoru
hexmd5(md5(part1)+md5(part2)+...)-{parts_count} gdzie pojedyncza część pliku jest wielkości 512 MB

Przykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5

Informacje szczegółowe o pliku

Licencja:
Creative Commons: by 4.0 otwiera się w nowej karcie
CC BY
Uznanie autorstwa

Informacje szczegółowe

Rok publikacji:
2020
Data zatwierdzenia:
2021-01-04
Data wytworzenia:
2020
Język danych badawczych:
angielski
Dyscypliny:
  • Automatyka, elektronika i elektrotechnika (Dziedzina nauk inżynieryjno-technicznych)
DOI:
Identyfikator DOI 10.34808/r3h7-d082 otwiera się w nowej karcie
Weryfikacja:
Politechnika Gdańska

Słowa kluczowe

Powiązane zasoby

Cytuj jako

wyświetlono 98 razy