Characteristics of odors emitted from municipal wastewater treatment plant and methods for their identification and deodorization techniques - Publikacja - MOST Wiedzy

Wyszukiwarka

Characteristics of odors emitted from municipal wastewater treatment plant and methods for their identification and deodorization techniques

Abstrakt

Odors emitted from municipal wastewater treatment plants belong to a group of pollutants, which is the main cause of people complaining about atmospheric air quality. The limitation of emissions of unpleasant odors generated by wastewater treatment plants by using appropriate deodorization methods is omitted on numerous occasions. This can have a negative inflence on public trust and the quality of atmospheric air. The article presents basic information on the characteristics of odors from wastewater treatment lines and wastewater processing and management lines in a model biological wastewater treatment plant conducting the biogas recovery process and also information is provided on deodorization methods, such as odor masking, biofiltration, thermal disposal and diffusion through activated sludge dedicated to neutralization of odors in biological treatment plants. The main focus is on the field olfactometry technique, which is one of the tools used in environmental protection. Its application facilitates performance of tests concerning the assessment of olfactory properties of odorants in polluted air.

Cytowania

  • 1 0 5

    CrossRef

  • 0

    Web of Science

  • 1 1 4

    Scopus

Cytuj jako

Pełna treść

pobierz publikację
pobrano 1000 razy
Wersja publikacji
Accepted albo Published Version
Licencja
Creative Commons: CC-BY-NC-ND otwiera się w nowej karcie

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuł w czasopiśmie wyróżnionym w JCR
Opublikowano w:
ENVIRONMENTAL RESEARCH nr 151, strony 573 - 586,
ISSN: 0013-9351
Rok wydania:
2016
Opis bibliograficzny:
Kolasińska P., Cieślik B., Dymerski T., Konieczka P., Namieśnik J.: Characteristics of odors emitted from municipal wastewater treatment plant and methods for their identification and deodorization techniques// ENVIRONMENTAL RESEARCH. -Vol. 151, (2016), s.573-586
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1016/j.envres.2016.08.030
Bibliografia: test
  1. References EN 13725, E., 2003. Air quality. Determination of odour concentration by dynamic olfactometry, s.l.: s.n. otwiera się w nowej karcie
  2. Aatamila, M., et al., 2011. Odour annoyance and physical symptoms among re- sidents living near waste treatment centres. Environ. Res. 111, 164-170. otwiera się w nowej karcie
  3. Agus, E., Zhang, L., Sedlak, L.D., 2012. A framework for identifying characteristic odor compounds in municipal wastewater effluent. Water Res. 46, 5970-5980. otwiera się w nowej karcie
  4. Alfonsin, C., et al., 2015. Selection of odour removal technologies in wastewater treatment plants: a guideline based on life cycle assessment. J. Environ. Manag. 149, 77-84. otwiera się w nowej karcie
  5. Alnaqbi, M., Bufaroosha, M., Al-Marzouqi, M., Marzouk, S., 2016. Portable analyzer for continuous monitoring of sulfur dioxide in gas stream based on ampero- metric detection and stabilized gravity-driven flow. Sens. Actuators B Chem. 225, 24-33. otwiera się w nowej karcie
  6. Anet, B., et al., 2013. Characterization of gaseous odorous emissions from a ren- dering plant by GC/MS and treatment by biofiltration. J. Environ. Manag. 128, 981-987. otwiera się w nowej karcie
  7. Annadurai, G., Juang, R., Yen, P., Lee, D., 2003. Use of thermally treated waste bio- logical sludge as dye absorbent. Adv. Environ. Res. 7, 739-744. otwiera się w nowej karcie
  8. Barczak, R., Kulig, A., Szyłak-Szydłowski, M., 2012. Olfactometric methods applica- tion for odour nuisance assessment of wastewater treatment facilities in Po- land. Chem. Eng. Trans. 30, 187-192. otwiera się w nowej karcie
  9. Boeker, P., Haas, T., Schulze Lammers, P., 2013. Theory and practice of a variable dome splitter for gas chromatography-olfactometry. J. Chromatogr. A 1286, 200-207. otwiera się w nowej karcie
  10. Bokowa, A., 2012. Ambient odour assessment similarities and differences Between Different Techniques. Chem. Eng. Trans. 30, 313-318. otwiera się w nowej karcie
  11. Brandt, R., Johnston, T., Toffey, W., Golembeski, J., 2009. Use of Field Olfactometry for Quantification of WWTP Dewatering Facility Odor Emissions. Orlando, FL, USA, s.n. otwiera się w nowej karcie
  12. Brattoli, M., et al., 2011. Odour Detection methods: olfactometry and chemical sensors. Sensors 11, 5290-5322. otwiera się w nowej karcie
  13. Bruszkiewski, H., Skorupski, W., 1999. Air pollution caused by a concentrated liquid waste treatment plant. Chem. inżynieria Ekol. 10, 979-987.
  14. Bufaroosha, M., Alnaqbi, M., Al-Marzouqi, M., Marzouk, S., 2013. Portable dual- channel gas analyzer for continuous monitoring of carbon dioxide in gas streams. Microchem. J. 110, 185-191. otwiera się w nowej karcie
  15. Cesca, J.F.A., Cunnington, M., Hall, M., 2007. Case Study: Odour Risk Management at the WTP, One of Australia's Largest and Most Unique WWTPS. Canyon,TX, USA, s.n. otwiera się w nowej karcie
  16. Chen, Y.-C., Higgins, M., Beightol, S., Murthy, S., 2011. Anaerobically digested bio- solids odor generation and pathogen indicator regrowth after dewatering. Water Res. 45, 2616-2626. otwiera się w nowej karcie
  17. Chen, Y., et al., 2016. The performance of a two-layer biotrickling filter filled with new mixed packing materials for the removal of H2S from air. J. Environ. Manag. 165, 11-16. otwiera się w nowej karcie
  18. Cieślik, B.M., Namieśnik, J., Konieczka, P., 2015. Review of sewage sludge manage- ment: standards, regulations and analytical methods. J. Clean. Prod. 90, 1-15. otwiera się w nowej karcie
  19. Doshi, V.A., Vuthalurua, H., Bastowb, T., 2005. Investigations into the control of odour and viscosity of biomass oil derived from pyrolysis of sewage sludge. Fuel Process. Technol. 86, 885-897. otwiera się w nowej karcie
  20. El-Shafai, S., Gijzen, H., Nasr, F., El-Gohary, F., 2004. Microbial quality oftilapia reared in fecal-contaminated ponds. Environ. Res. 95, 231-238. otwiera się w nowej karcie
  21. Fang, J.-J., et al., 2012. Odor compounds from different sources of landfill: char- acterization and source identification. Waste Manag. 32, 1401-1410. otwiera się w nowej karcie
  22. Fulazzaky, A.M., Talaiekhozani, A., Majid, A.Z.M., 2016. Formaldehyde removal mechanisms in a biotrickling filter reactor. Ecol. Eng. 90, 77-81. otwiera się w nowej karcie
  23. Giungato, P., et al., 2016. Improving recognition of odors in a waste management plant by using electronic noses with different technologies, gas chromato- graphy-mass spectrometry/olfactometry and dynamic olfactometry. J. Clean. Prod. 133, 1395-1402. otwiera się w nowej karcie
  24. Hamel, K., Walters, P., Sulerud, C., McGinley, M., 2004. Land Application Odor Control Case Study. Salt Lake City, UT, s.n. otwiera się w nowej karcie
  25. Hort, C., Gracy, S., Platel, V., Moynault, L., 2009. Evaluation of sewage sludge and yard waste compost as a biofilter media for the removal of ammonia and vo- latile organic sulfur compounds (VOSCs). Chem. Eng. J. 152, 44-53. otwiera się w nowej karcie
  26. Kim, H., et al., 2014. Characterization of odor emission from alternating aerobic and anoxic activated sludge systems using real-time total reduced sulfur analyzer. Chemosphere 117, 394-401. otwiera się w nowej karcie
  27. Kośmider, J., Krajewska, B., 2007. Determining temporary odour concentration under field conditions -comparison of methods. Pol. J. Environ. Stud. 16 (2), 215-225.
  28. Kośmider, J., Mazur-Chrzanowska, B., Wyszyński, B., 2012. Odory. Wydawnictwo Naukowe PWN, Warszawa.
  29. Krach, K.R., Li, B., Burns, B.R., Mangus, J., 2008. Bench and full-scale studies for odor control from lime stabilized biosolids: the effect of mixing on odor generation. Bioresour. Technol. 99, 6446-6455. otwiera się w nowej karcie
  30. Latos, M., Karageorgos, P., Kalogerakis, N., Lazaridis, M., 2011. Dispersion of odorous gaseous Compounds Emitted from Wastewater Treatment Plants. Water Air Soil Pollut. 215 (1), 667-677. otwiera się w nowej karcie
  31. Lay, A.M., McGinley, C., 2004. A nasal chemosensory performance test for odor inspectors. Bellevue, WA, s.n. otwiera się w nowej karcie
  32. Lebrero, R., Gabriela, M., Rangel, L., Muñoz, R., 2013. Characterization and biofil- tration of a real odorous emission from wastewater treatment plant sludge. J. Environ. Manag. 116, 50-57. otwiera się w nowej karcie
  33. Lebrero, R., Rodríguez, E., García-Encina, P.A., Munoz, R., 2011. A comparative as- sessment of biofiltration and activated sludge diffusion for odour abatement. J. Hazard. Mater. 190, 622-630. otwiera się w nowej karcie
  34. Lehtinen, J., Veijanen, A., 2011. Odour monitoring by combined TD-GC-MS-Sniff technique and dynamic olfactometry at the wastewater treatment plant of low H2S concentration. Water Air Soil Pollut. 218, 185-196. otwiera się w nowej karcie
  35. Liu, H., et al., 2014. Combined effects of Fenton peroxidation and CaO conditioning on sewage sludge thermal drying. Chemosphere 117, 559-566. otwiera się w nowej karcie
  36. Liu, H., et al., 2012. Emission characteristics of nitrogen-and sulfur-containing odorous compounds during different sewage sludge chemical conditioning processes. J. Hazard. Mater., 298-306. otwiera się w nowej karcie
  37. Liu, N., et al., 2016. Controlling odors from sewage sludge using ultrasound coupled with Fenton oxidation. J. Environ. Manag. 181, 124-128. otwiera się w nowej karcie
  38. Lotito, V., Lotito, A.M., 2014. Rheological measurements on different types of sew- age sludge for pumping design. J. Environ. Manag. 137, 189-196. otwiera się w nowej karcie
  39. Marzouk, S., Al-Marzouqi, M., 2012. Analyzer for continuous monitoring of H2S in gas streams based on a novel thermometric detection. Sens. Actuators B Chem. 162 (1), 377-383. otwiera się w nowej karcie
  40. Marzouk, S., Al-Marzouqi, M., Baomran, S., 2010. Simple analyzer for continuous monitoring of sulfur dioxide in gas streams. Microchem. J. 95 (2), 207-212. otwiera się w nowej karcie
  41. McGinley, C. M., McGinley, M., 2002. Impact of the New European Odor Testing Standard on Wastewater Treatment Facilities. Atlanta, GA, USA, s.n. otwiera się w nowej karcie
  42. Otten, L., Afzal, M., Mainville, D., 2004. Biofiltration of odours: laboratory studies using butyric acid. Adv. Environ. Res. 8, 397-409. otwiera się w nowej karcie
  43. Pathak, A., Dastidar, M., Sreekrishnan, T., 2009. Bioleaching of heavy metals from sewage sludge: a review. J. Environ. Manag. 90, 2343-2353. otwiera się w nowej karcie
  44. Plutowska, B., Wardencki, W., 2012. Gas chromatography-olfactometry of alcoholic beverages. In: Alcoholic Beverages. Woodhead Publihing Limited, pp. 101-130 (Chapter 5). otwiera się w nowej karcie
  45. Potivichayanon, S., Pokethitiyook, P., Kruatrachue, M., 2006. Hydrogen sulfide re- moval by a novel fixed-film bioscrubber system. Process Biochem. 41, 708-715. otwiera się w nowej karcie
  46. Rajbansi, B., Sarkar, U., Hobbs, S.E., 2014. Hazardous odor markers from sewage wastewater: a step towards simultaneous assessment, dearomatization and removal. J. Taiwan Inst. Chem. Eng. 45, 1549-1557. otwiera się w nowej karcie
  47. Rosenfeld, P., Suffet, I., 2004. Understanding odorants associated with compost, biomass facilities, and the land application of biosolids. Water Sci. Technol. 49 (9), 193-199. otwiera się w nowej karcie
  48. Scaglia, B., et al., 2011. Odours and volatile organic compounds emitted from mu- nicipal solid waste at different stage of decomposition and relationship with biological stability. Bioresour. Technol. 102, 4638-4645. otwiera się w nowej karcie
  49. Shao, L.-M., et al., 2014. Effects of bulking agent addition on odorous compounds emissions during composting of OFMSW. Waste Manag. 34, 1381-1390. otwiera się w nowej karcie
  50. Suffet, I., Burlingame, G., Rosenfeld, P., Bruchet, A., 2004. The value of an odor- quality-wheel classification scheme for wastewater treatment plants. Water Sci. Technol. 50 (4), 25-32. otwiera się w nowej karcie
  51. Talaiekhozani, A., Bagheri, M., Goli, A., Khoozani, T.R.M., 2016. An overview of principles of odor production, emission, and control methods in wastewater collection and treatment systems. J. Environ. Manag. 170, 186-206. otwiera się w nowej karcie
  52. Tsang, Y.F., Wang, L., Chong, H., 2015a. Effects of high ammonia loads on nitrogen mass balance and treatment performance of a biotrickling filter. Process Saf. Environ. Prot. 98, 253-260. otwiera się w nowej karcie
  53. Tsang, Y.F., Wang, L., Chua, H., 2015b. Simultaneous hydrogen sulphide and am- monia removal in a biotrickling filter: crossed inhibitory effects among selected pollutants and microbial community change. Chem. Eng. J. 281, 389-396. otwiera się w nowej karcie
  54. Witherspoon, J., Barnes, J., 2004. Comparison of Methods Used to Measure Odour at Wastewater Treatment Plant Fencelines. Cologne, Germany, s.n.
  55. Wu, H., et al., 2016. Removal of methyl acrylate by ceramic-packed biotrickling filter and their response to bacterial community. Bioresour. Technol. 209, 237-245. otwiera się w nowej karcie
  56. Yulin, X., Weijiang, Z., Hao, Z., 2010. Synergetic decolorization and deodorization of sludge protein foaming solution by 60Co gamma-ray irradiation/H2O2 oxida- tion. Process Saf. Environ. Prot. 88, 285-291. otwiera się w nowej karcie
  57. Zhang, X.L., Yana, S., Tyagi, R.D., Surampalli, R.Y., 2013. Odor control in lagoons. J. Environ. Manag. 124, 62-71. otwiera się w nowej karcie
Weryfikacja:
Politechnika Gdańska

wyświetlono 236 razy

Publikacje, które mogą cię zainteresować

Meta Tagi