Real-time isothermal DNA amplification monitoring in picoliter volumes using an optical fiber sensor - Publikacja - MOST Wiedzy

Wyszukiwarka

Real-time isothermal DNA amplification monitoring in picoliter volumes using an optical fiber sensor

Abstrakt

Rolling circle amplification (RCA) of DNA can be considered as a great alternative to the gold standard polymerase chain reaction (PCR), especially during this pandemic period, where rapid, sensitive, and reliable test results for hundreds of thousands of samples are required daily. This work presents the first research to date on direct, real-time and label-free isothermal DNA amplification monitoring using a microcavity in-line Mach–Zehnder interferometer (μIMZI) fabricated in an optical fiber. The solution based on μIMZI offers a great advantage over many other sensing concepts – making possible optical analysis in just picoliter sample volumes. The selectivity of the biosensor is determined by DNA primers immobilized on the microcavity's surface that act as selective biorecognition elements and trigger initiation of the DNA amplification process. In this study, we verified the sensing concept using circular DNA designed to target the H5N1 influenza virus. The developed biosensor exhibits an ultrahigh refractive index sensitivity reaching 14 000 nm per refractive index unit and a linear detection range between 9.4 aM and 94 pM of the target DNA sequence. Within a 30 min period, the amplification of as little as 9.4 aM DNA can be effectively detected, with a calculated limit of detection of as low as 0.2 aM DNA, suggesting that this methodology holds great promise in practical disease diagnosis applications in the future.

Cytowania

  • 3 3

    CrossRef

  • 0

    Web of Science

  • 3 3

    Scopus

Autorzy (7)

Cytuj jako

Pełna treść

pełna treść publikacji nie jest dostępna w portalu

Słowa kluczowe

Informacje szczegółowe

Kategoria:
Publikacja w czasopiśmie
Typ:
artykuły w czasopismach
Opublikowano w:
LAB ON A CHIP nr 21, strony 397 - 404,
ISSN: 1473-0197
Język:
angielski
Rok wydania:
2021
Opis bibliograficzny:
Janik M., Hamidi S., Koba M., Perreault J., Walsh R., Bock W., Śmietana M.: Real-time isothermal DNA amplification monitoring in picoliter volumes using an optical fiber sensor// LAB ON A CHIP -Vol. 21,iss. 2 (2021), s.397-404
DOI:
Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1039/d0lc01069c
Weryfikacja:
Politechnika Gdańska

wyświetlono 116 razy

Publikacje, które mogą cię zainteresować

Meta Tagi