Verification of Formulas for Periods of Adjacent Buildings Used to Assess Minimum Separation Gap Preventing Structural Pounding during Earthquakes
Abstrakt
Insufficient separation distance between adjacent buildings may lead to serious damages during earthquakes due to structural pounding. The best way to prevent collisions is to provide sufficiently large separation distance between the structures. In this paper, the periods of two closely-spaced linear and nonlinear buildings have been investigated so as to accurately assess the minimum in-between separation gap. A new equation to calculate the effective periods of inelastic buildings has been proposed and its effectiveness has been verified through numerical analysis. The results of the investigation conducted for inelastic buildings with different number of stories indicate that the proposed formula allows us to prevent earthquake-induced structural pounding by ensuring adequate value of seismic gap.
Cytowania
-
1 1
CrossRef
-
0
Web of Science
-
1 9
Scopus
Autorzy (4)
Cytuj jako
Pełna treść
- Wersja publikacji
- Accepted albo Published Version
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1155/2019/9714939
- Licencja
- otwiera się w nowej karcie
Słowa kluczowe
Informacje szczegółowe
- Kategoria:
- Publikacja w czasopiśmie
- Typ:
- artykuł w czasopiśmie wyróżnionym w JCR
- Opublikowano w:
-
Advances in Civil Engineering
nr 2019,
strony 1 - 8,
ISSN: 1687-8086 - Język:
- angielski
- Rok wydania:
- 2019
- Opis bibliograficzny:
- Khatami S. M., Naderpour H., Barros R., Jankowski R.: Verification of Formulas for Periods of Adjacent Buildings Used to Assess Minimum Separation Gap Preventing Structural Pounding during Earthquakes// Advances in Civil Engineering. -Vol. 2019, (2019), s.1-8
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1155/2019/9714939
- Weryfikacja:
- Politechnika Gdańska
wyświetlono 161 razy
Publikacje, które mogą cię zainteresować
Effective Gap Size Index for Determination of Optimum Separation Distance Preventing Pounding between Buildings during Earthquakes
- S. M. Khatami,
- H. Naderpour,
- A. Mortezaei
- + 3 autorów
Earthquake-Induced Pounding of Medium-to-High-Rise Base-Isolated Buildings
- H. Naderpour,
- P. Danaeifard,
- D. Burkacki
- + 1 autorów
The Effectiveness of Rubber Bumpers in Reducing the Effects of Earthquake-Induced Pounding between Base-Isolated Buildings
- K. Mohamma Seyed,
- H. Naderpour,
- A. Mortezaei
- + 3 autorów