Publications
Filters
total: 309
Catalog Publications
Year 2009
-
Destructive Consequences of PWM Inverter Feeding for Traction AC Motors
PublicationThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the...
-
Editorial [general conference information and history]
Publication -
Evaluative analysis of 2- and 3-level DC/DC converters for high-voltage high-power applications
Publication -
Modelling and analysis of a synchronous generator in more electric aircraft power system using Synopsys/Saber simulator = Modelowanie i analiza generatora synchronicznego w systemie elektroenergetycznym nowoczesnego samolotu. Zastosowanie symulatora Synopsys/Saber
PublicationStreszczenie angielskie: A model for studying synchronous machine (SM) dynamic behaviour in more electric aircraft (MEA) power system is developed and implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SM model. The elaborated model exhibit a network with the same number of external terminals/ports as the real SM, and represents its behaviour in terms of the electrical...
-
Modelling of Voltage Transformer Performance in Power System Harmonic Frequency Range
PublicationZniekształcenia harmoniczne napięć i prądów występujące we współczesnych systemach energetycznych powodują liczne problemy pomiarowe. W referacie przedstawiono analizę właściwości przekładników napięciowych stosowanych w sieciach SN i WN w zakresie częstotliwości mierzonych zniekształceń harmonicznych. Opracowany szerokopasmowy model obwodowy został zweryfikowany symulacyjnie i eksperymentalnie. Wyniki przeprowadzonych badań potwierdzają...
-
Modelowanie propagacji i filtracji zniekształceń w lokalnych sieciach elektroenergetycznych
Publicationstr. 67-69, 9 rys., 4 poz. lit.W referacie opisano przykład wpływu pracy UPS o mocy 30 kVA na sieć zasilającą i odbiorczą. Prostownik typu boost PWM pobiera prąd o znacznej zawartości harmonicznych przy podstawowej częstotliwości 11 kHz i jest źródłem zaburzeń propagowanych na obwody odbiorcze. Za cel pracy przyjęto odwzorowanie obserwowanych procesów generacji i propagacji zaburzeń za pomocą modelowania obwodowego.
-
Modelowanie wpływu kabla silnikowego na emisję zaburzeń elektromagnetycznych przewodzonych przekształtnikowych układów napędowych prądu przemiennego
PublicationAnaliza propagacji składowych wspólnych prądów zaburzeń przewodzonych w przekształtnikowych układach napędowych z silnikami prądu przemiennego wymaga uwzględniania pojemności pasożytniczych występujących w przekształtniku, silniku oraz w kablu zasilającym. W artykule przedstawiono metodę analizy charakterystyki częstotliwościowej impedancji obciążenia przekształtnika i zaproponowano model obwodowy, który pozwala na przeprowadzanie...
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
Publication -
New type T-Source inverter
PublicationThis paper presents different topologies of voltage inverters with alternative input LC networks. The basic topology is known in the literature as a Z-source inverter (ZSI). Alternative passive networks were named by the authors as T-sources. T-source inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage of the T-source inverter (TSI) is its use of a common voltage...
-
New type T-Source inverter
Publication -
Niekorzystny wpływ przekształtnikowego zasilania PWM na silniki asynchroniczne trakcyjne
PublicationThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the...
-
Nonlinear model of a synchronous generator for analysis of more electric aircraft power systems
PublicationA nonlinear model for studying a variable-speed synchronous generator (SG) in more electric aircraft (MEA) power system has been developed. The saturation effects of the SG magnetic circuit have been considered. The model has been implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SG model. The model exhibit a network with the same number of external terminals/ports...
-
Nowe wymagania jakości energii wytwarzanej przez elektrownie wiatrowe
PublicationZapewnienie odpowiedniego poziomu jakości energii w systemie elektroenergetycznym dla wszystkich odbiorców jest jednym z ważniejszych współczesnych problemów technicznych. Elektrownie wiatrowe coraz częściej instalowane w wielu miejscach wpływają w istotnym stopniu na stan jakości energii w rozległych obszarach sieci elektroenergetycznej w rejonie ich zainstalowania. W artykule przedstawiono najważniejsze negatywne oddziaływania...
-
Praca regulatora generatora w warunkach sprzyjających powstawaniu lawiny napięcia - wybrane problemy
PublicationW referacie zwrócono uwagę na wybrane zagadnieniazwiązane z pracą wieloparametrowego regulatora generatoraw warunkach awarii napięciowej. Przedstawiono wynikianalizy wpływu tak często pomijanego elementu układuregulatora generatora, jakim jest stabilizator systemowy.Zwrócono uwagę na celowość automatyzacji procesu zaniżaniamocy czynnej, dla zwiększenia możliwości generacjimocy biernej. Ponadto wskazano błędy w strukturze torugłównego...
-
The Influence of Limiters UEL and OEL (The power angle, stator's current and excitation current) ot the possibility of voltage collapse development
PublicationVoltage stability has been a major concern for power system utilities because of event of voltage collapses in the recent past. Sometimes, power system events have shown the need for generators to operate in the overexcited and underexcited region to support stable operation. Modern excitation systems include devices for controlling or limiting machine terminal voltage (overvoltage limiters), volts per hertz ratio (V/Hz limiters),...
-
Wpływ obecnie stosowanych układów regulacji generatorów na możliwości pogłębienia awarii napięciowej
PublicationArtykuł przedstawia badania symulacyjne zachowania się obecnie stosowanych struktur układów regulacji generatorów na pracę systemu elektroenergetycznego i możliwość pogłębienia awarii napięciowej.
-
Wpływ obecnie stosowanych układów regulacji generatorów na możliwości pogłębienia awarii napięciowej
PublicationArtykuł przedstawia badania symulacyjne pracy generatora synchronicznego wyposażonego w wieloparametrowy regulator generatora o strukturach spotykanych obecnie w KSE. W pracy analizowano wpływu struktury i nastawień regulatora generatora synchronicznego na pracę systemu elektroenergetycznego w warunkach awarii napięciowej
-
Wpływ regulatora prędkości turbozespołu na przebieg procesu wydzielania wyspy
PublicationNiniejsza praca poświęcona jest analizie: wpływu układów regulacji turbin parowych na proces wydzielania się podsystemów elektroenergetycznych i ich współdziałania z układami automatyki SCO.
-
Wpływ struktury, algorytmów działania oraz nastawień układów regulatorów transformatorów 110/SN na możliwość powstania i przebieg awarii napięciowej
PublicationReferat przedstawia zagadnienia związane z możliwością pogłębienia deficytu mocy biernej w wyniku działania regulatorów transformatorów 110kV/SN. Rozważania teoretyczne rozszerzono o wyniki pomiarów oraz badania symulacyjne. Wnioski przedstawione w końcowej części referatu powstały w wyniku krytycznej analizy stanu obecnego pracy układów regulacji stacji 110kV/SN.
-
Wpływ struktury maszyn bezszczotkowych z magnesami trwałymi na rozkład pola wzbudzenia
PublicationRozwój maszyn elektrycznych jest ściśle związany z rozwojem inżynierii materiałowej jak również przyrządów półprzewodnikowych mocy i mikroprocesorów stanowiących podstawowe elementy współczesnych układów energoelektronicznych do przetwarzania i sterowania mocy elektrycznej. Zastosowanie magnesów trwałych (MT) o dużych gęstościach energii pozwala budować maszyny elektryczne, które charakteryzują się lepszymi parametrami eksploatacyjnymi...
Year 2008
-
Active Power Quality Controllers
PublicationDynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...
-
Analiza i realizacja sterowania serwonapędami w trzech osiach przez sterownik programowalny z wykorzystaniem opisu zadania poprzez G-KOD
PublicationObrabiarki sterowane komputerowo są obecnie powszechnie wykorzystywane w zautomatyzowanych procesach produkcji. Zadania realizowane przez te obrabiarki są najczęściej opisywane z wykorzystaniem G-kodu. W przypadku, gdy potrzebna jest realizacja jedynie podstawowych funkcji obrabiarki, a do takich należy realizacja ruchu narzędzia, nie zawsze istnieje potrzeba stosowania obrabiarek. Podstawowe funkcje sterowania z powodzeniem mogą...
-
Cascaded doubly fed induction generator for mini and micro power plants connected to grid
Publication -
Control strategies and comparison of the Dynamic Voltage Restorer
PublicationThis paper focuses on a selection problems of mitigation of the voltage disturbance by of the Dynamic Voltage Restorers (DVR’s). In short form presented and discussed are the basis of different control strategies of the DVR. The main emphasis is placed on application of modern power electronic devices. Authors of this paper in particular occupy oneself with analysis of the power rating of the typically DVR topologies. These problems...
-
Czteropoziomowy falownik napięcia 6 kV typu "Diode Clamped". Budowa i sterowanie.
PublicationW artykule rozpatrzono zagadnienia budowy falowników PWM dużej mocy i średniego napięcia. Opisano model laboratoryjny 4-poziomowego falownika napięcia typu "Diode Clamped", przeznaczony do weryfikacji eksperymentalnej rozwiązań "software" i "hardware" takiego pierwszego polskiego prototypu 6kV/1MVA. Przedstawiono algorytm SVPWM zaimplementowany w układzie DSP. Zamieszczono wybrane wyniki eksperymentalne badań modelu oraz omówiono...
-
Decentralized control of a UPS systems operating in parallel
Publication -
Half-order analytical modelling of ferromagnetic sheet. Validation with finite elements simulation
Publication -
Modeling of generator performance of BLDC machine using mathematica software
PublicationW artykule porównano trzy modele maszyny bezszczotkowej prądu stałego z magnesami trwałymi(BLDC) w przypadku pracy prądnicowej. Najprostszy model qd0 sprowadzono do dwóch osi prostopadłychzwiązanych z wirnikiem [3]. Zakłada on sinusoidalny rozkład pola w szczelinie. Model opisany wosiach naturalnych wyprowadzono w oparciu o formalizm Lagrnage'a [4] i moŜe uwzględniać dowolnyrozkład pola wzbudzonego przez magnesy trwałe. Model pośredni...
-
New control system of the shunt active power filter
Publication -
Non-linear circuit model of a single doubly-fed induction machine formulated in natural axes for drive systems simulation purposes
PublicationMathematical modelling and a circuit model formulated in natural axes of a single doubly-fed induction machine, with the account of magnetic circuit nonlinearity are presented in the paper. Derivation of the model differential equations was based on Lagrange's energy method. State functions of magnetic elements in the model are non-linear and depend on all currents flowing in the machine windings and on the angle of rotor position....
-
Ocena zgodności regulatorów automatyki z wymaganiami dyrektyw LVD i EMC
PublicationArtykuł przedstawia wstępną analizę wymagań normy PN - EN 60730-1 dotyczącej automatycznych regulatorów elektrycznych do użytku domowego. Podana norma ma status normy zharmonizo-wanej i w związku z tym spełnienie jej wymagań umożliwia producentowi wykazanie zgodności wprowadzonego na rynek wyrobu z wymaganiami dyrektyw - niskonapięciowej (LVD) i kompatybilności elektromagnetycznej (EMC). W artykule szerzej opisano wymagania mające...
-
Power flow in typical series-parallel hybrid filters topologies
Publication -
Power quality conditioners with minimum number of current sensor requirement
Publication -
Predictive control system of the shunt active power filter
Publication -
Small power laboratory model and high power prototype of the four-level VSI
Publication -
The Wiener filter applied to EMI decomposition
PublicationArtykuł przestawia zastosowanie metody filtracji Wienera do dekompozycji zaburzeń elektromagnetycznych z różnych źródeł. Zaburzenia generowane w trójfazowym rezonansowym falowniku napięcia typy PQRDCLI oraz w przekształtniku napięcia stałego zasilającego obwód sterowania falownika zostały zmierzone z zastosowaniem sieci sztucznej (LISN). W oparciu o transmitancje częstotliwościowe pomiędzy źródłami zaburzeń i zaburzeniami zmierzonymi...
-
Transformacja przebiegów odkształconych w przekładnikach napięciowych
PublicationZagadnienia związane z jakością energii elektrycznej dostarczanej poprzez system elektroenergetyczny są obecnie jednym z ważniejszych problemów coraz częściej występujących w wielu relacjach pomiędzy dostawcą i odbiorcą energii. Zagadnienia te regulowane są poprzez odpowiednie dokumenty normalizacyjne, które określają szczegółowe wymagania dotyczące parametrów jakości energii dostarczanej przez dostawcę, a także ustalają graniczne...
-
Wiener Filtering Applied to Conducted EMI Estimation in Soft Switching Inverter
PublicationW artykule tym przedstawiono metodę szacowania poziomu zaburzeń elektromagnetycznych przewodzonych generowanych w miekko-przełączalnym falowniku napięcia. Wykorzystano metodę filtracji Wienera, gdzie wykorzystano skończoną liczbę filtrów Wienera jako odzwierciedlenie wszystkich warunków generacji i propagacji zaburzeń. Do określenia transmitancji filtrów wykorzystano przebiegi napięć na zaciskach łączników energoelektronicznych...
-
Wpływ ograniczników: kąta mocy, prądu stojana i wzbudzenia na rozwój awarii napięciowej
PublicationArtykuł prezentuje badania symulacyjne dotyczące wpływu ograniczników: kąta mocy, prądu stojana i prądu wzbudzenia na pracę i rozwój awarii napięciowej w systemie elektroenergetycznym. W badaniach brano pod uwagę rozwiązania analogowe oraz obecnie montowane cyfrowe układy automatycznej regulacji napięcia.
-
Zaburzenia radioelektryczne wytwarzane przez nowoczesne urządzenia oświetleniowe
PublicationW artykule zaprezentowano zmienione wymagania normalizacyjne w zakresie emisji zaburzeń radioelektrycznych dla urządzeń oświetleniowych oraz przedstawiono przykładowe wyniki pomiarów emisyjności powszechnie stosowanych świetlówek kompaktowych w odniesieniu do innych źródeł swiatła.
Year 2007
-
A diode rectifier with a Special Coupled Reactor and additional Active Power Filter in the Marine Local Power Network Supply Conditions
Publication -
A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter
Publication -
A Special Multi-Pulse Converter with Small Active Power Filter
Publication -
Analiza wpływu indukcyjności czół uzwojenia jednowarstwowego silnika asynchronicznego klatkowego na jego właściwości dynamiczne
PublicationPraca dotyczy zagadnienia obliczania indukcyjności czół uzwojenia stojanów silników asynchronicznych klatkowych małej mocy. Przedstawiono wybrane wyniki analizy uzwojenia na przebiegi prądów stojana, momentu elektromagnetycznego i prędkości kątowej podczas rozruchu bezpośredniego silnika. Do analizy zastosowano metodę symulacyjną, wykorzystującą model obwodowy silnika opracowany w ujęciu energetycznym Lagrange'a. Parametry modelu...
-
Assessment of usefulness of different tacks in laparoscopic ventral hernia repair
PublicationLaparoscopic ventral hernia repair is becoming a popular technique with good results and fast postoperative recovery. The mesh is placed directly under the peritoneum and anchored with transabdominal sutures and tacks. However, the ideal size of the mesh covering the hernia orifice is know, nor the ideal type or amount of tacks has to be described.
-
Buck-Boost Inverters with Symmetrical Passive Four-terminal Networks
Publication -
Decentralized control of a different rated parallel UPS systems
PublicationThe paper presents the single phase uninterruptible power supply (UPS) system with galvanic separated DC-AC-DC-AC converters operating in parallel. The CAN physical layer based system of communication between converters has been developed and applied, which allow to utilize a decentralized master-slave control providing high availability factor of the whole UPS system. The control system of particular converters has been developed...
-
Estymacja napięcia niezrównoważenia w obwodzie pośredniczącym falownika trójpoziomowego NPC na podstawie analizy prądów wyjściowych
PublicationZaproponowano prostą i skuteczną metodę wyznaczania wartości napięcia niezrównoważenia w obwodzie pośredniczącym trójpoziomowego falownika NPC (ang. Neutral-Point-Clamped). Zastosowanie proponowanej metody nie wymaga dodatkowych czujników pomiarowych, a nakłady obliczeniowe na realizację algorytmu są niewielkie. Do wyznaczania napięcia niezrównoważenia wykorzystuje się informacje zawarte w mierzonych prądach wyjściowych falownika....
-
Exercise bike powered electric generator for fitness club appliances
PublicationA generator powered by a stationary bicycle for the purposes of generating electricity for fitness club appliances is considered. A generator is connected to a stationary bicycle in such a way as the circular rotation of the front wheel rotates the coils of wires inside the generator between the poles of the magnets inside the generator. The resulting Direct Current is channeled to the attached battery bank and converted into different...
-
Exercise bike powered electric generator for fitness club appliances
Publication