Department of Power Electronics and Electrical Machines - Administrative Units - Bridge of Knowledge

Search

Department of Power Electronics and Electrical Machines

Filters

total: 313

  • Category
  • Year
  • Options

clear Chosen catalog filters disabled

Catalog Publications

Year 2006
Year 2013
Year 2007
Year 2003
  • A filter bank solution for active power filter control algorithms
    Publication

    - Year 2003

    Thb paper describes the proposed active power fiIter (APF) with a new control circuit based on an algorithm using ufilter bank and a harmonic predictor. The conirol circuit was realized using the digiiaI signor processor ADSP-21065L and FPGA circuiL In the proposed circuit transient performunee of APF is improved The active power fdter circuil has been built and teste6 and some illustrative, experimental results are uIso presented...

    Full text to download in external service

  • A model of combined heat and power generating plant with urban heat distribution network for production scheduling
    Publication

    - Year 2003

    Poruszono zagadnienie związane z pracowaniem harmonogramu produkcji elektrociepłowni. Uwzględniony został wpływ zachowania się miejskiej sieci ciepłowniczej na pracę elektrociepłowni. Możliwe jest również modelowanie współpracy ze zbiornikiem ciepła.

  • Analiza światowych i krajowych prognoz energetycznych
    Publication

    W referacie omówiono aktualne prognozy energetyczne obejmujące swym zasięgiem Świat, Europę i Polskę w różnych horyzontach czasowych. Przeanalizowano trzy najważniejsze bieżące prognozy energetyczne sporządzone dla całego świata oraz omówiono przewidywania rozwoju sektora energetyki w Unii Europejskiej w obecnych granicach. Na tym tle omówiono prognozę rozwoju energetyki w Polsce zwartą w "Założeniach polityki energetycznej państwa...

Year 2014
Year 2012
  • A Method Supporting Monitoring And Repair Processes of Information Systems
    Publication

    - Year 2012

    W pracy zaproponowano nową metodę (ARM) zarządzania monitorowaniem i naprawą systemów IT, bez przerywania ciągłości ich funkcjonowania. Metoda ta integruje procesy monitorowania (uwzględniając już istniejące i stosowane rozwiązania) z procesami naprawy. Stworzono formalny model koncepcyjny opisujący dziedzinę monitorowania i naprawy oraz formalne specyfikacje mechanizmu napraw oraz wybranych procedur naprawczych. Do specyfikacji...

    Full text to download in external service

  • Behawioralne modelowanie tranzystorów IGBT do symulacji układów energoelektronicznych
    Publication

    - Year 2012

    W monografii dokonano syntezy behawioralnego modelu tranzystora IGBT o strukturze klasycznej, odzwierciedlającego właściwości statyczne oraz dynamiczne IGBT. Zaproponowane metody identyfikacji parametrów modelu bazują na danych katalogowych oraz wynikach eksperymentalnych. Do zaproponowanych metod identyfikacji parametrów modelu wymagane są dane katalogowe, tj. charakterystyki statyczne: iC(uGE), uC(uCE) oraz charakterystyka dynamiczna...

Year 2016
Year 2011
  • A robust 18-pulse diode rectifier with coupled reactors

    The article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...

    Full text available to download

  • A Successful ISIE 2011
    Publication

    - Year 2011

    W artykule przedstawiono przebieg międzynarodowej konferencji "20th IEEE International Symposium on Industrial Electronics", zorganizowanej przez Wydział Elektrotechniki i Automatyki PG pod patronatem IEEE Industrial Electronics Society (IES) w dniach 27-30.06.2011 r. W konferencji uczestniczyło ok. 380 uczestników, w tym ponad 80% z zagranicy. W artykule sprawozdano wygłoszone seminaria dydaktyczne, referaty plenarne i najlepsze...

    Full text to download in external service

Year 2009
Year 2020
Year 2004
  • Accurate modeling of layout parasitic to forecast EMI emitted from a DC-DC converter.
    Publication

    - Year 2004

    This paper illustrates how to account for all parasitic due to the layout of a power converter (inductive and capacitive), in order to forecast electromagnetic interferences (EMI). The method is generic, and is validated here in the simple example of a DC-DC converter, realized on different technologies: insulated metal substrate (IMS), printed circuit board (PCB). In addition, several layouts aspects will be investigated. Conclusions...

  • Adaptacyjna kompensacja wpływu czasu martwego w falowniku napięcia z modulacją szerokości impulsów.
    Publication

    Przedstawiono nową metodę kompensacji wpływu czasu martwego na napięcia wyjściowe trójfazowego falownika mostkowego. Proponowana metoda umożliwia automatyczne dopasowanie parametrów kompensacji do aktualnych parametrów falownika i obciążenia, np. po zmianie przewodu łączącego falownik z obciążeniem. Adaptacja do nowych warunków polega na dostrajaniu wartości parametrów zależności opisującej napięcie błędu w funkcji prądu fazowego....

  • Automatyka odciążająca wykorzystująca elementy logiki rozmytej.
    Publication

    - Year 2004

    W referacie przedstawiono nowy algorytm automatyki odciążającej oparty na elementach logiki rozmytej. Zastosowanie układu Rozmytej Adaptacyjnej Automatyki Odciążającej (RAAO). Zaletą układu RAAO jest możliwość wyłączania dowolnej liczby grup odbiorów, objętych działaniem automatyki odciążającej, w dowolnej fazie procesu odciążania. Dzięki takiemu rozwiązaniu uzyskano znaczną poprawę zarówno skuteczności jak i jakości procesu odciążania....

Year 2008
  • Active Power Quality Controllers
    Publication

    - Year 2008

    Dynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...

    Full text to download in external service

  • Analiza i realizacja sterowania serwonapędami w trzech osiach przez sterownik programowalny z wykorzystaniem opisu zadania poprzez G-KOD
    Publication

    - Year 2008

    Obrabiarki sterowane komputerowo są obecnie powszechnie wykorzystywane w zautomatyzowanych procesach produkcji. Zadania realizowane przez te obrabiarki są najczęściej opisywane z wykorzystaniem G-kodu. W przypadku, gdy potrzebna jest realizacja jedynie podstawowych funkcji obrabiarki, a do takich należy realizacja ruchu narzędzia, nie zawsze istnieje potrzeba stosowania obrabiarek. Podstawowe funkcje sterowania z powodzeniem mogą...

Year 2005
Year 2010
Year 2002
Year 2015
Year 2001