Application of a commercially available derivatization instrument and commonly used reagents to HPLC on-line determination of antioxidants
Abstract
This study demonstrates the potential of a commercially available derivatization instrument coupled with HPLC for separation and on-line determination of antioxidants detected with widely used screening reagents - DPPH (2,2-diphenyl-1-picrylhydrazyl), ABTS (2,2'-azino-bis(3-ethylbenzthiazoline-6-sulphonic acid) or FCR (Folin-Ciocalteu's phenol reagent ). As the result of optimization, key parameters of the analytical procedure, were established: concentrations of derivatization reagents 1.5 mmol/L and 2.1 mmol/L in methanol for DPPH and ABTS, respectively and 40 % (v/v) FCR solution in water; reactor temperatures 130 oC for ABTS and FCR and 50 oC in the case of DPPH. In order to validate these procedures, Trolox equivalent antioxidant capacities (TEAC) for standard antioxidants obtained by post-column derivatization (on-line) and typical batch colorimetric methods (off-line) were compared; the corresponding measurements were found to be strongly correlated (Pearson coefficient: 0.973, 0.922, 0.853 for DPPH, ABTS and FCR, respectively). The results obtained for standard antioxidants and real fruit sample - aronia extract, confirm the applicability of the proposed system to the on-line detection of antioxidants. Its great advantage compared to current routine methods is that it provides chromatographic profiles and corresponding fingerprints of antioxidants (including unknown ones) along with quantitative determination of antioxidative potential, both - total and exhibited by individual compounds.
Citations
-
2 9
CrossRef
-
0
Web of Science
-
2 9
Scopus
Authors (4)
Cite as
Full text
- Publication version
- Accepted or Published Version
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuł w czasopiśmie wyróżnionym w JCR
- Published in:
-
JOURNAL OF FOOD COMPOSITION AND ANALYSIS
no. 24,
edition 7,
pages 1073 - 1080,
ISSN: 0889-1575 - Language:
- English
- Publication year:
- 2011
- Bibliographic description:
- Kusznierewicz B., Piasek A., Bartoszek-Pączkowska A., Namieśnik J.: Application of a commercially available derivatization instrument and commonly used reagents to HPLC on-line determination of antioxidants// JOURNAL OF FOOD COMPOSITION AND ANALYSIS. -Vol. 24, iss. 7 (2011), s.1073-1080
- DOI:
- Digital Object Identifier (open in new tab) 10.1016/j.jfca.2011.01.010
- Verified by:
- Gdańsk University of Technology
seen 181 times