Modeling of multi-cavity Fabry-Perot optical fiber sensors - Publication - Bridge of Knowledge

Search

Modeling of multi-cavity Fabry-Perot optical fiber sensors

Abstract

Reflectance characteristics of a two-cavity extrinsic Fabry-Perot optical fiber sensor were investigated using computer modeling. Calculations were performed using a plane wave-based approach, selected for clarity of results. Based on the modeling results, it can be concluded that the two-cavity Fabry-Perot interferometer can be used to measure two different quantities, such as refractive index and temperature, independently. It is also possible to use one of its cavities as a wavelength or optical path length reference, especially when a tunable laser is used as a light source. Spectral signal processing needed in such sensor is not substantially more complicated than that used in single cavity sensors.

Citations

  • 1

    CrossRef

  • 0

    Web of Science

  • 5

    Scopus

Cite as

Full text

full text is not available in portal

Keywords

Details

Category:
Conference activity
Type:
materiały konferencyjne indeksowane w Web of Science
Title of issue:
16th Conference on Optical Fibers and their Applications strony 1 - 6
Language:
English
Publication year:
2015
Bibliographic description:
Wierzba P..: Modeling of multi-cavity Fabry-Perot optical fiber sensors, W: 16th Conference on Optical Fibers and their Applications, 2015, SPIE, the international society for optics and photonics,.
DOI:
Digital Object Identifier (open in new tab) 10.1117/12.2223011
Verified by:
Gdańsk University of Technology

seen 62 times

Recommended for you

Meta Tags