Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
Abstract
A new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included selection of a plasticizer for the ion-selective membrane composition and type of the electrode material. The study was carried out using ISE with liquid internal electrolyte (LE-ISE) and solid-contact electrodes made of glassy carbon (GC-ISE) and gold rods (Au-ISE). The best parameters were found for GC sensors for which the ion-selective membrane contained chloroparaffin as a plasticizer (S = 59.9 mV/dec, LOD = 1.6 × 10−6 M). The study of potentiometric selectivity coefficients has shown that the thiocyanate-selective sensor could be applied in biomedical research for determination of SCN− concentration in human saliva. The accuracy of the SCN− determination was verified by testing 59 samples of volunteers’ saliva by potentiometric sensors and UV-Vis spectrophotometry as a reference technique. Moreover, SCN− concentrations in the smokers’ and non-smokers’ saliva were compared. In order to investigate the influence of various factors (sex, health status, taken medications) on the thiocyanate level in the saliva, more extensive studies on a group of 100 volunteers were carried out. Additionally, for a group of 18 volunteers, individual profiles of SCN− concentration in saliva measured on a daily basis for over a month were collected.
Citations
-
1 5
CrossRef
-
0
Web of Science
-
1 4
Scopus
Authors (5)
Cite as
Full text
- Publication version
- Accepted or Published Version
- DOI:
- Digital Object Identifier (open in new tab) 10.3390/s20102817
- License
- open in new tab
Keywords
Details
- Category:
- Articles
- Type:
- artykuły w czasopismach
- Published in:
-
SENSORS
no. 20,
ISSN: 1424-8220 - Language:
- English
- Publication year:
- 2020
- Bibliographic description:
- Urbanowicz M., Sadowska K., Pijanowska D., Pomećko R., Bocheńska M.: Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva// SENSORS -Vol. 20,iss. 10 (2020), s.2817-
- DOI:
- Digital Object Identifier (open in new tab) 10.3390/s20102817
- Verified by:
- Gdańsk University of Technology
seen 140 times
Recommended for you
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
- M. Urbanowicz,
- D. G. Pijanowska,
- A. Jasiński
- + 2 authors
The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
- M. Urbanowicz,
- D. G. Pijanowska,
- A. Jasiński
- + 1 authors
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
- A. Jasiński,
- M. Urbanowicz,
- M. Guziński
- + 2 authors