Didn't find any results in this catalog!
But we have some results in other catalogs.Filters
total: 1562
displaying 1000 best results Help
Search results for: green corrosion inhibitor
-
Development Of Dynamic Method For Evaluation Of Corrosion Rate On The Example Of Organic Corrosion İnhibitor
PublicationMeasurements of the corrosion rate belong to the most important aspects of materials science. In order to reduce material loss corrosion inhibitors are used. However selection of proper inhibitor should be based on evaluation of its mechanism and effective concentrations. Mechanism of inhibition usually has dynamic character so physicochemical parameters are changing in time. Most of actually used methods...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
PublicationThis paper presents an implementation of the monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in a utility water installation using an automated corrosion monitoring system. Due to the fact that the corrosion inhibitor was added to water intended for human consumption, it was necessary to build a multi-sensor monitoring system. In order to implement corrosion monitoring using a linear...
-
Sodium nitrite as a corrosion inhibitor of copper in simulated cooling water
PublicationThe corrosion inhibition behavior of sodium nitrite (NaNO2) towards pure copper (99.95%) in simulated cooling water (SCW) was investigated by means of electrochemical impedance spectroscopy (EIS) and dynamic electrochemical impedance spectroscopy (DEIS). NaNO2 interferes with metal dissolution and reduce the corrosion rate through the formation or maintenance of inhibitive film on the metal surface. Surface morphologies illustrated...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
Publication -
The corrosion studies of 3,4,5-trihydroxybenzoic acid as an effective corrosion inhibitor of low alloy steel
Open Research DataThe dataset contains the electrochemical studies evaluating if gallic acid is a corrosion inhibitor for low alloy steel. Three measurements were carried out each case; corrosion potential (label ecorr), electrochemical impedance spectroscopy (label eis) and cyclic polarization (label cp). The measurements were carried out in sodium chloride, acidified...
-
Galvanostatic impedance measurements for the efficient adsorption isotherm construction in corrosion inhibitor studies
PublicationWe present an approach towards an accurate and time-efficient adsorption isotherm determination to evaluate the corrosion inhibitor interaction in electrolytic environments. The approach is based on dynamic impedance spectroscopy measurements in galvanostatic mode (g-DEIS). The studied corrosion inhibitor is continuously injected between the secondary cell and the corrosion cell. The efficiency corresponding to instantaneous inhibitor...
-
Corrosion hazards and inhibitor protection in the seawater injection system on the Baltic sea rig
PublicationOil extraction efficiency in LOTOS Petrobaltic Company is increased by means of injection of seawater into an oilfield aquifer, which is implemented on the Baltic Beta rig, operating on the Baltic Sea. Operational experience has shown a significant degree of corrosion aggressiveness in the injected water, which necessitates frequent repairs of the seawater injection installation. Evaluation of the corrosion phenomena is crucial...
-
Vitamin B9 as a new eco-friendly corrosion inhibitor for copper in 3.5% NaCl solution
PublicationFolic acid salt (sodium folate) was studied as an eco-friendly and non-toxic copper corrosion inhibitor in 3.5% NaCl solution. Electrochemical impedance spectroscopy, polarization resistance and weight-loss measurements show that the inhibitor efficiency increases with concentration (the highest value- approx. 96% was reported for the solution containing 16 mM sodium folate after 24 h). EIS data and Tafel plots indicate that sodium...
-
Assessment of copper surface coverage with corrosion inhibitor using AFM-based local electrical measurements
PublicationThe paper presents a new method of assessment of metal surface coverage with corrosion inhibitor and thus of inhibitor protective performance. It is based on the atomic force microscopy measurement performed in a contact mode. Apart from topography images the proposed approach allows acquisition of local DC maps and local electrical impedance spectra via application of DC bias voltage or AC perturbation signal between the conductive...
-
Experimental and Quantum Chemical Evaluation of 8-Hydroxyquinoline as a Corrosion Inhibitor for Copper in 0.1 M HCl
PublicationThe corrosion inhibition properties of 8-hydroxyquinoline (8-HQ) in 0.1 M HCl for copper have been investigated by using experimental (electrochemical impedance spectroscopy (EIS), dynamic electrochemical impedance spectroscopy (DEIS), and potentiodynamic polarization) and theoretical methods complemented by surface morphological examination with the aid of scanning electron microscopy (SEM) and electron dispersive X-ray spectroscopy...