Miniaturized impedance analyzer using AD5933
PublicationThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Miniaturized impedance analyzer using AD5933
PublicationThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Analyzer for spectroscopy of low-impedance objects
PublicationW artykule przedstawiono analizator umożliwiający pomiar impedancji w zakresie 1 ohma < |Zx| < 100 Mohma. Zastosowano w nim nowe rozwiązania dotyczące obwodu wejściowego i techniki detekcji fazoczułej sygnałów pomiarowych. Obwód wejściowy zaprojektowano w postaci 5-zaciskowej sondy pomiarowej, która umożliwia ograniczenie wpływu rezystancji, indukcyjności i pojemności pasożytniczych na błąd pomiaru impedancji w szerokim przedziale...
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublicationW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwości od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublicationW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwosci od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 200 mV
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 0 V
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 600 mV
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 400 mV
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Open Research DataThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 48h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
A family of new generation miniaturized impedance analyzers for technical object diagnostics
PublicationThe paper presents the family of three analyzers allowing to measure impedance in range of 10 ohm<|Zx|<10 Gohm in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzers family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of impedance measurement method based on digital signal processing DSP. The miniaturization and other above mentioned...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system
PublicationThis paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...
-
Fast High-Impedance Spectroscopy Method Using SINC Signal Excitation
PublicationIn this paper the method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 Gohm) is evaluated by means of simulation and practical experiment. The method is based on excitation of an object with a sinc signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance spectrum is obtained with use of continuous Fourier transform...
-
Using A Particular Sampling Method for Impedance Measurement
PublicationThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...