Comparison of near infrared spectroscopy (NIRS) and near-infrared transillumination-backscattering sounding (NIR-T/BSS) methods
PublicationThe aim of the study was to compare simultaneously recorded a NIR-T/BSS and NIRS signals from healthy volunteers. NIR-T/BSS is a device which give an ability to non-invasively detect and monitor changes in the subarachnoid space width (SAS). Experiments were performed on a group of 30 healthy volunteers (28 males and 2 females, age 30.8 ± 13.4 years, BMI = 24.5 ± 2.3 kg/m2). We analysed recorded signals using analysis methods based...
-
Use of Near Infrared Transillumination/Back Scattering Sounding (NIR-T/BSS) to assess effects of elevated intracranial pressure on width of subarachnoid space and celebrovascular pulsation in animals
PublicationW pracy dokonano ocenę zmiany szerokości przestrzeni podpajęczynówkowej i tętnienia naczyń mózgowych w czasie chwilowego zwiększenia ciśnienia śródczaszkowego u królików doświadczalnych. Badania zostały przeprowadzone przy wykorzystaniu metody transiluminacji w bliskiej podczerwieni z rozpraszaniem zwrotnym NIRT-BSS.
-
Subarachnoid Space: New Tricks by an Old Dog
PublicationPurpose: The purpose of the study was to: (1) evaluate the subarachnoid space (SAS) width and pial artery pulsation in both hemispheres, and (2) directly compare magnetic resonance imaging (MRI) to near-infrared transillumination/backscattering sounding (NIR-T/BSS) measurements of SAS width changes in healthy volunteers.Methods: The study was performed on three separate groups of volunteers, consisting in total of 62 subjects (33...
-
Effects of consecutive apneas on pial artery pulsation and subarachnoid width in healthy subjects
PublicationHypercapnia is known to dilate the pial artery, disrupt cerebral autoregulation and increase pial artery pulsation. The cerebral blood flow velocity (CBFV) response to hypercapnia is biphasic. Below the threshold for the increase of blood pressure (BP) with carbon dioxide partial pressure (pCO2), the CBFV measurement reflects vascular reactivity to pCO2 alone at a constant BP. Above this threshold, the CBFV measurement provides...
-
Human subarachnoid space width oscillations in the resting state
PublicationAbnormal cerebrospinal fluid (CSF) pulsatility has been implicated in patients suffering from various diseases, including multiple sclerosis and hypertension. CSF pulsatility results in subarachnoid space (SAS) width changes, which can be measured with near-infrared transillumination backscattering sounding (NIR-T/BSS). The aim of this study was to combine NIR-T/BSS and wavelet analysis methods to characterise the dynamics of the...
-
Effect of Maximal Breath Hold Apnea on Pial Artery Pulsation and Subarachnoid Width in Human
PublicationLittle is known about intracranial pressure (ICP)-cerebral hemodynamic interplay during maximal breath-hold apnea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. Changes in sas-TQ correlate with ICP to a considerable extent, whereas cc-TQ reflects the functional...
-
Pial artery and subarachnoid width response to apnoea in normal humans
PublicationBackground: Little is known about intracranial pressure (ICP)-cerebral haemodynamic interplay during repetitive apnoea. A recently developed method based on near-infrared transillumination/backscattering sounding (NIR-T/BSS) noninvasively measures changes in pial artery pulsation (cc-TQ) as well as subarachnoid width (sas-TQ) in humans. Method: We tested the complex response of the pial artery and subarachnoid width to apnoea...
-
Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency
PublicationPial artery adjustments to changes in blood pressure (BP)may last only seconds in humans. Using a novelmethod called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) in humans, we aimed to assess the relationship between spontaneous oscillations in BP and cc-TQ at frequencies between 0.5 Hz and 5 Hz. We hypothesized that analysis of...
-
Effect of Maximal Apnoea Easy-Going and Struggle Phases on Subarachnoid Width and Pial Artery Pulsation in Elite Breath-Hold Divers
PublicationPurpose: The aim of the study was to assess changes in subarachnoid space width (sas-TQ), the marker of intracranial pressure (ICP), pial artery pulsation (cc-TQ) and cardiac contribution to blood pressure (BP), cerebral blood flow velocity (CBFV) and cc-TQ oscillations throughout the maximal breath hold in elite apnoea divers. Non-invasive assessment of sas-TQ and cc-TQ became possible due to recently developed method based on...
-
Modelowanie wpływu bezdechu na zmiany szerokości przestrzeni podpajęczynówkowej u zdrowych ochotników
PublicationDiagnostyka głowy oraz stanu mózgu jest jedną z najtrudniejszych w medycynie. Ze względu na skomplikowaną budowę i dużą wrażliwość mózgu na uszkodzenia, ważne jest rozwijanie metod diagnostycznych. Obecnie stosowane metody, takie jak rezonans magnetyczny czy tomograf komputerowy dają znakomite efekty, ale nie pozwalają na ciągły monitorowania zmian, które, na przykład po wypadku bądź po urazie mechanicznym, mogą być kluczowe dla...
-
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublicationUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
Effect of the welding environment and storage time of electrodes on the diffusible hydrogen content in deposited metal
PublicationIn the study the glycerin displacement method was used for determination of diffusible hydrogen content in deposited metal. Specimens were welded in the air and in the water with covered rutile electrodes. The first part of the specimens was made immediately after opening the package of the electrodes. The electrodes were then stored in opened packages in laboratory conditions that allowed for contact with the air for three years....
-
Elective surgery system strengthening: development, measurement, and validation of the surgical preparedness index across 1632 hospitals in 119 countries
Publication