Didn't find any results in this catalog!
But we have some results in other catalogs.Filters
total: 1693
-
Catalog
- Publications 1166 available results
- Journals 33 available results
- Conferences 10 available results
- People 53 available results
- Inventions 1 available results
- Projects 10 available results
- Research Teams 1 available results
- Research Equipment 11 available results
- e-Learning Courses 44 available results
- Events 3 available results
- Open Research Data 361 available results
displaying 1000 best results Help
Search results for: SLOPE ADC
-
Single-Slope ADC With Embedded Convolution Filter for Global-Shutter CMOS Image Sensors
PublicationThis brief presents an analog-to-digital converter (ADC) suitable for acquisition and processing of images in the global-shutter mode at the pixel level. The ADC consists of an analog comparator, a multi-directional shift register for the comparator states, and a 16-bit reversible binary counter with programmable step size. It works in the traditional single-slope mode. The novelty is that during each step of the reference ramp,...
-
A Power-Efficient Digital Technique for Gain and Offset Correction in Slope ADCs
PublicationIn this brief, a power-efficient digital technique for gain and offset correction in slope analog-to-digital converters (ADCs) has been proposed. The technique is especially useful for imaging arrays with massively parallel image acquisition where simultaneous compensation of dark signal non-uniformity (DSNU) as well as photo-response non-uniformity (PRNU) is critical. The presented approach is based on stopping the ADC clock by...
-
Hybrid‐mode single‐slope ADC with improved linearity and reduced conversion time for CMOS image sensors
PublicationIn the paper, a single‐slope analog‐to‐digital converter (ADC) for integrated CMOS image sensor applications with an improved technique of conversion has been proposed. The proposed hybrid‐mode ADC automatically uses one of the following conversion techniques: time based (i.e. PWM) or voltage based (i.e. single‐slope). During the ADC operation, the clock frequency and reference voltage are modified in order to reduce the conversion...
-
Scope
Journals -
Probabilistic analysis of slope with planar slip surface
PublicationPraca dotyczy probabilistycznej oceny stateczności zboczy. Omówiono sposób określania prawdopodobieństwa utraty stateczności przy wykorzystaniu metody momentów (ang. FOSM). Podejście takie zastosowano do analizy zsuwu konsekwentnego jednorodnego zbocza. Rozpatrzono wpływ zmienności statystycznej parametrów wytrzymałościowych na końcowe wyniki.
-
Slope Reinforcement with the Utilization of the Coal Waste Anthropogenic Material
Publication -
Experimental study of the effect of vertical acceleration component on the slope stability
PublicationThe paper deals with the stability of earth dams subjected to seismic and paraseismic excitations occurring in the close distance to the dam. The Newmark’s stability approach, classified as a simplified dynamic method, has been extended for two directional dynamic loading case and the evolution of the friction coefficient. The paper is focused on the experimental verification of the proposed method for harmonic and cyclic excitations...
-
Effect of excitation intensity on slope stability assessed by a simplified approach
PublicationThe paper concerns the selection of a design accelerograms used for the slope stability assessment under earthquake excitation. The aim is to experimentally verify the Arias Intensity as an indicator of the excitation threat to the slope stability. A simple dynamic system consisting of a rigid block on a rigid inclined plane subjected to horizontal excitation is adopted as a slope model. Strong ground motions recorded during earthquakes...
-
Slope Stability Analysis of Zoned Earth Dam with RCC Overtopping Protection
Publication -
High meniscal slope angle as a risk factor for meniscal allograft extrusion
PublicationA meniscal graft extrusion is still an unresolved problem that affects most patients after a meniscal transplantation. Despite the advances in surgical techniques, together with the improved methods for a meniscal allograft sizing, success is only observed in up to 75% of patients after they experience a meniscal allograft transplantation. Because a meniscal extrusion is associated with a cartilage deterioration and the progression...