prof. dr hab. inż. Małgorzata Szczerska
seria: Measurement spectrum obtained with the use of ALD coated microsphere-based fiber-optic sensor liczba: 38
rozwiń zwiń-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.5
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.4
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.3
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 90 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 80 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 75 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 70 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 65 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 60 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 50 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 45 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 35 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapasitor with the use of ZnO coated microsphere-based fiber-optic sensor - 30 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Measurement spectrum obtained with the use of ZnO coated (100 nm) microsphere-based fiber-optic sensor - 200 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 100 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated (100 nm) microsphere-based fiber-optic sensor - 100 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 100 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-0optic sensor - 250 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 300 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated (100 nm) microsphere-based fiber-optic sensor - 300 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 100 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 290 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 280 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 240 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 160 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 180 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 200 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 210 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 270 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 190 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 260 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 170 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 150 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 230 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Short-term measurement of physiological parameters - teenager (5 min) 6.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) 7.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (25 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (20 min) 2.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)_3.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (10 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (20 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 6.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (10 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (40 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (40 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (30 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 2.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 3.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 4.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 5.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (15 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (25 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (15 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (13h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (13 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (10h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (10 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (4h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (9h and 20min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (9 hours and 20 minutes) measurement of physiological parameters was performed on...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 12. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 11. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 10th series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 9th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 8th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 7th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 6th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 5 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 4 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 2 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (150 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 150 minutes) measurement of physiological parameters was performed on the healthy...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 100 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 10 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 100 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Long-term measurement of physiological parameters - patient 7 (serie 18)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hour) measurement of physiological parameters of the healthy volunteer (female,...
-
Long-term measurement of physiological parameters - patient 7 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters of the healthy volunteer (female,...
-
Long-term measurement of physiological parameters - patient 7 (serie 21)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2.5 hour) measurement of physiological parameters of the healthy volunteer (female,...
-
Long-term measurement of physiological parameters - patient 7 (serie 20)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hour) measurement of physiological parameters of the healthy volunteer (female,...
-
Long-term measurement of physiological parameters - patient 7 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hour) measurement of physiological parameters of the healthy volunteer (female,...
-
Long-term measurement of physiological parameters - patient 7 (serie 17)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hour) measurement of physiological parameters of the healthy volunteer (female,...
-
Long-term measurement of physiological parameters - patient 7 (serie 16)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (1.5 hour) measurement of physiological parameters of the healthy volunteer (female,...
-
Long-term measurement of physiological parameters - patient 7 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (1 hour) measurement of physiological parameters of the healthy volunteer (female,...
-
Long-term measurement of physiological parameters - patient 7 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (1 hour) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2.5 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 7 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2.5 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 7 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (1.5 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 7 (serie 8)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 9)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (1 hour) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (1 hour) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 23)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 21)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 20)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 18)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 17)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 16)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (8 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 9)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 8)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 23)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 21)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 20)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 18)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 17)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 16)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 9)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 8)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (9 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 25)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 24)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 23)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 21)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 20)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 18)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 17)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 16)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 8)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 9)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (7 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 16)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 17)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 18)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 4 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 9)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 8)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 25)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 24)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 23)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (6 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 21)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 20)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (6 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 25)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 24)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 23)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 21)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 20)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 18)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 17)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 16)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (6 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (6 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 9)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 8)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (6 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 25)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 8)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 9)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 16)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 17)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 18)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 20)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 21)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 23)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 24)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Short-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurement of physiological parameters were performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (100 minutes) 2nd serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (100 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (90 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (60 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) - the 2nd serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (105 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (105 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (100 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (100 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (70 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (70 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (60 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (100 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (100 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (120 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (120 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Short-term measurement of physiological parameters - adult (35 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (35 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - adult (20 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - adult (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (30 minutes) measurement of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - adult (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurement of physiological parameters were performed on the healthy...
-
Dependence of biological sensing on temperature based on investigation of SARS-CoV-2
Dane BadawczePresented dataset is the result of an investigation of the attachment of SARS-CoV-2 specific IgG in the temepratures relevant in biology. The samples were measured during a period of 15 minutes, at 5°C, 25°C and 55°C. The measurements were performed using the microspher-based fiber-optic sensor, as an interferometer. The broadband optical light source...
-
Experimental dataset on detection of SARS-CoV-2 specific IgG antibodies by the fiber optic microsphere-based sensor
Dane BadawczeThe presented dataset is related to experimental detection of the ARS-CoV-2 specific IgG antibodies by the fibre optic microsphere-based sensor. To perform measurement we used a dedicated microsphere-based probe whose surface was immobilized.
-
Hemocompatibility of nanocrystalline diamond layers
Dane BadawczeThe biocompatibility of the diamond films were investigated with whole human blood samples. Blood used in this study was drawn from 10 healthy human patients of different age, sex, and blood group. A 2 ml samples were collected into standard tubes with EDTA anticoagulation agent. Blood was used within 6 hours from the collection time. A reference blood...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 110 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement of the temperature change of PVCP tissue phantom illuminated by dermatological laser 1.series
Dane BadawczeApplication of laboratory set-up for characterization of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes a thermographic camera VIGOcam v50 and a dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 10 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Optical Parameters Stability Over Time of Porous Phantoms Mimicking Tissues
Dane BadawczeOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom...
-
Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser.
Dane BadawczeApplication of laboratory set-up for characterisation of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes thermographic camera VIGOcam v50 and dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 140 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 130 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 120 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 100 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Long-term measurement of physiological parameters - child (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...
-
Distance measurement by the low coherent interferometer
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Long-term measurement of physiological parameters.
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
wyświetlono 8444 razy