Reinforced concrete thin wall dome after eighty years of operation in maritime climate environment
The paper presents a description of the construction elements of the Gdynia Seaport main hall dome. Firstly, it provides information about the technical condition of the dome’s structure. Secondly, it examines the strength analysis of the thin-walled reinforced concrete dome covering. Throughout the last 80 years the building has been exposed to an unfavourable marine climate. The analysis of the state of stress and deformations...
-
Dome over the Gdynia seaport building
The paper presents the description of structure and the selected problems of the technical condition, as well as the strength analysis of the thin-walled reinforced concrete shell which has been making a covering of the main hall of the Gdynia Seaport Building through the last 80 years. The rectangle projection of four single curvature shells of the dome was shaped out of mutual perpendicular intersection of two cylindrical shells. The...
-
Badania rozkładu temperatury na grubości płaszcza żelbetowego zbiornika oczyszczalni ścieków w okresie zimowym
Podczas eksploatacji zbiorników oczyszczalni ścieków na skutek różnicy temperatury ścieków a temperaturą powietrza na zewnątrz, powstają oddziaływania termiczne, które w przypadku nieocieplonej ściany żelbetowego zbiornika na ciecz, mogą przyczynić się do powstania zarysowań [1.] co w konsekwencji może doprowadzić do utraty szczelności. Powstałe na skutek różnic temperatur naprężenia rozciągające sumują się z naprężeniami wnikającymi...