Opis
The biocompatibility of the diamond films were investigated with whole human blood samples. Blood used in this study was drawn from 10 healthy human patients of different age, sex, and blood group. A 2 ml samples were collected into standard tubes with EDTA anticoagulation agent. Blood was used within 6 hours from the collection time. A reference blood smear was conducted as a control sample before further experiments. Peripheral blood smears were performed on diamond thin films. The smears were analyzed within 15 minutes, with the use of a bright field microscope (Nikon Eclipse 80) with a 1000x magnification using an immersion objective.
The investigated samples:
0k - nanocrystalline diamond layers
2.5 k - boron-doped nanocrystalline diamond layer (level 2.5 k during PVD)
5k - boron-doped nanocrystalline diamond layer (level 5 k during PVD)
7.5k - boron-doped nanocrystalline diamond layer (level 7.5 k during PVD)
10k - boron-doped nanocrystalline diamond layer (level 10 k during PVD)
Plik z danymi badawczymi
hexmd5(md5(part1)+md5(part2)+...)-{parts_count}
gdzie pojedyncza część pliku jest wielkości 512 MBPrzykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5
Informacje szczegółowe o pliku
- Licencja:
-
otwiera się w nowej karcieCC BY-NCUżycie niekomercyjne
- Dane surowe:
- Dane zawarte w datasecie nie zostały w żaden sposób przetworzone.
Informacje szczegółowe
- Rok publikacji:
- 2020
- Data zatwierdzenia:
- 2021-09-10
- Data wytworzenia:
- 2015
- Język danych badawczych:
- angielski
- Dyscypliny:
-
- Automatyka, elektronika i elektrotechnika (Dziedzina nauk inżynieryjno-technicznych)
- inżynieria biomedyczna (Dziedzina nauk inżynieryjno-technicznych)
- DOI:
- Identyfikator DOI 10.34808/kbpa-w968 otwiera się w nowej karcie
- Ethical papers:
- This study was approved by the Bioethics Committee of the Medical University of Lublin according to the Guidelines for Good Clinical Practice on 20th December 2012 (protocol no. KE-0254/293/2012).
- Weryfikacja:
- Politechnika Gdańska
Słowa kluczowe
Powiązane zasoby
- publikacja Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
- publikacja Haemocompatibility of Modified Nanodiamonds
- publikacja Measurement of complex refractive index of human blood by low-coherence interferometry
- publikacja Optical Investigation of Hematocrit Level in Human Blood
- publikacja Optimization of a Fabry-Perot Sensing Interferometer design for an optical fiber sensor of hematocrit level
- publikacja Blood equivalent phantom vs whole human blood, a comparative study
- publikacja Nitrogen-Doped Diamond Film for Optical Investigation of Hemoglobin Concentration
Cytuj jako
Autorzy
Wersja ten dokument posiada różne wersje
-
wersja 1.4Data publikacji wersji 2021-12-14
-
wersja 1.3Data publikacji wersji 2021-12-14
-
wersja 1.2Data publikacji wersji 2021-12-14
-
Aktualna wersjawersja 1.1Data publikacji wersji 2021-09-10
-
wersja 1.0Data publikacji wersji 2020-12-17
wyświetlono 135 razy