Measurements of reactive power distribution in a ship power station with two generators working in parallel - Open Research Data - MOST Wiedzy

Wyszukiwarka

Measurements of reactive power distribution in a ship power station with two generators working in parallel

Opis

The presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2),  developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing a reactive power distribution in a ship power station.

The measurement setup is shown in Fig. 1.  A measurement system based on NI PXIe-1062Q was used as a reference instrument for the E/A instrument performance assessment.

The dataset file was created on the base of the selected data derived from two files: E_A.txt (research data: Selected results of signal measurements in a ship power station with two generators working in parallel with the use of the Estimator/Analyzer instrument, R. Maśnicki D. Hallmann J. Mindykowski T. Tarasiuk M. Górniak M. Szweda, DOI:10.34808/dv88-sj58) and PXI.txt (research data: Selected results of measurements carried out in a ship power station with two generators working in parallel with the use of the NI PXIe-1062Q based measurement system, R. Maśnicki D. Hallmann J. Mindykowski T. Tarasiuk M. Górniak M. Szweda, DOI:10.34808/h2xb-8a23). Raw data from these files, after appropriate calculations and after time synchronization of the obtained results, were used to determine the parameters included in the file.

The individual rows of data contain the reactive power values designated with a time step of 200 ms using data obtained from the E/A instrument (Q1 E/A and Q2 E/A) as well as from the PXI system (Q1 PXI and Q2 PXI) during measurements in a ship power station with two operating generators G1 and G2. Since the reactive power  E/A was calculated for the line voltages, and the reactive power PXI values were calculated using phase voltages, additional columns for power PXI values were added, corrected for the root of 3.

Ilustracja publikacji

Fig. 1. The measurement setup

Plik z danymi badawczymi

reactive_power.xls
270.0 kB, S3 ETag fe685e798a2e291aca1a106e73d3a342-1, pobrań: 61
Hash pliku liczony jest ze wzoru
hexmd5(md5(part1)+md5(part2)+...)-{parts_count} gdzie pojedyncza część pliku jest wielkości 512 MB

Przykładowy skrypt do wyliczenia:
https://github.com/antespi/s3md5

Informacje szczegółowe o pliku

Licencja:
Creative Commons: by 4.0 otwiera się w nowej karcie
CC BY
Uznanie autorstwa

Informacje szczegółowe

Rok publikacji:
2020
Data zatwierdzenia:
2020-12-17
Data wytworzenia:
2011
Język danych badawczych:
angielski
Dyscypliny:
  • Automatyka, elektronika i elektrotechnika (Dziedzina nauk inżynieryjno-technicznych)
DOI:
Identyfikator DOI 10.34808/1g3k-3783 otwiera się w nowej karcie
Weryfikacja:
Politechnika Gdańska

Słowa kluczowe

Powiązane zasoby

Cytuj jako

wyświetlono 150 razy