Effects of Column Base Flexibility on Seismic Response of Steel Moment-Frame Buildings
PublikacjaSteel Moment Resisting Frames (SMRFs) are very popular lateral load resisting systems in many seismically active regions. However, their seismic response is strongly dependent on the rotational fixity of column base connections. Despite many studies (both experimental and numerical) in this particular area, available approaches for estimating column base flexibility have been validated only against laboratory test data. In the...
-
Column base fixity in steel moment frames: Observations from instrumented buildings
PublikacjaThe rotational fixity of column base connections in Steel Moment Resisting Frames (SMRFs) strongly influences their seismic response. However, approaches for estimating base fixity have been validated only against laboratory test data. These approaches are examined based on strong motion recordings from four instrumented SMRF buildings in California to informbest practices for seismic response simulation. These buildings represent...
-
Effect of Base-Connection Strength and Ductility on the Seismic Performance of Steel Moment-Resisting Frames
PublikacjaColumn-base connections in steel moment-resisting frames (SMFs) in seismic regions are commonly designed to develop the capacity of adjoining column with an intent to develop a plastic hinge in the column member, rather than in the connection (i.e., a strong-base design). Recent research has shown base connections to possess high ductility, indicating that this practice may be not only expensive but also unnecessary. This suggests...
-
Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
PublikacjaThe scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear load capacity. The dimensions of the shear head should provide the punching shear resistance of the connection inside and outside the...
-
Influence of the Shear Cap Size and Stiffness on the Distribution of Shear Forces in Flat Slabs
PublikacjaThe scope of this paper is to investigate analytically and numerically the influence of shear cap size and stiffness on the distribution of shear forces in flat slabs in a slab–column-connections-reinforced concrete structure. The effect of support (shear cap) stiffness on the calculation of the length of the shear control perimeter according to the available methods is presented. Based on the analysis, the authors indicate in...
-
Enhancing seismic performance of steel buildings having semi-rigid connection with infill masonry walls considering soil type effects
PublikacjaUnpreventable constructional defects are the main issues in the case of steel Moment-Resisting Frames (MRFs) that mostly occur in the rigidities of beam-to-column connections. The present article aims to investigate the effects of different rigidities of structures and to propose Infill Masonry Walls (IMWs) as retrofitting strategy for the steel damaged buildings. A fault or failure to meet a certain consideration of the soil type...
-
Response of high voltage disconnector under seismic excitation - experimental and numerical study
PublikacjaThe efficiency of the energetic infrastructure system is a very import safety issue in the region experienced by the ground motion. The aim of the present paper is to show the results of the experimental and numerical study focused on the earthquake-induced response of the high voltage disconnector, which is an important element of energetic network. First, the impact tests as well as the sweep-sine shaking table tests were conducted....
-
Experimental study on the behaviour of steel columns under seismic-induced axial impact load
PublikacjaIt has been observed during major earthquakes that the so called soft-storey failure of an upper floor of a structure results in large impact load acting on structural members of the lower storeys. It may further lead to progressive collapse of the whole structure substantially intensifying human and material losses. Therefore, the aim of this paper is to investigate experimentally the behaviour of columns under bending (observed...
-
Study on transmission quality in cellular 4G and 5G networks between 2019–2021: Impact of the COVID-19 pandemic on the level of provided services by operating base transceiver stations
PublikacjaThe COVID-19 pandemic has significantly limited user mobility, not least among students. Remote learning had a particular impact on resource allocation in relation to using terrestrial cellular networks, especially 4G systems in urban agglomerations. This paper presents the results of a quality evaluation of an outdoor environment, carried out between 2019 and 2021 on the campus of a technical university. Annual studies are conducted...
-
Behaviour of deformed steel columns exposed to impact load during earthquakes: numerical analysis
PublikacjaIt has been observed during earthquakes that the so called soft-storey failure of an upper floor of a building leads to considerable vertical impact load acting on structural members of the lower storeys. The aim of this paper is to investigate numerically the behaviour of horizontally deformed columns (deformation as the result of earthquake loading) that are additionally subjected to vertical impact load. In the first stage of...