Wyniki wyszukiwania dla: CPMD - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: CPMD

Wyniki wyszukiwania dla: CPMD

  • Raman spectra of CPMH and CPMD

    Dane Badawcze
    open access

    These data contains Raman spectra of CPMH and CPMD. Raman scattering was measured with a RenishawmicroRaman spectrometer (785 nm). Sample abbreviations (CPMH, CPMD) are in agreement with the markings used in the linked publication. 

  • The results of the nitrogen adsorption/desorption measurements of CPMD and CPMH

    Dane Badawcze
    open access

    The results of the nitrogen adsorption/desorption measurements of CPMD and CPMH. The adsorption/desorption isothermswere carried out at 77 K using a Quantachrome Autosorb-1C-MS instrument. Sample abbreviations (CPMD, CPMH) are in agreement with the markings used in the linked publication. 

  • Evaluation of the electrochemical performance of CPMD in ZICs with 3M ZnSO4 electrolyte

    Dane Badawcze
    open access

    These data contain the results of the electrochemical performance measurements of CPMD in ZICs with 3M ZnSO4 electrolyte, incl. CGD (galvanostatic charge-discharge ) curve and cycling stability of CPMD. Sample abbreviations (CPMD) are in agreement with the markings used in the linked publication. 

  • CV (cyclic voltammetry) curves of the CPMD sample at different scan rates

    Dane Badawcze
    open access

     These data contain CV curves of CPMD obtained at a scan rate from 1 mV s−1 to 20 mV s−1. Sample abbreviations (CPMD) are in agreement with the markings used in the linked publication. 

  • XPS (X-ray photoelectron spectroscopy) survey spectra of CPMD and CPMH

    Dane Badawcze
    open access

    XPS (X-ray photoelectron spectroscopy) survey spectra of CPMD and CPMH. XPS spectra were obtained using Al Kɑ (hv=1486.6 eV) radiation with a Prevac system equipped with a Scienta SES 2002 electron energy analyzer operating at constant transmission energy (Ep=50 eV). Sample abbreviations (CPMD, CPMH) are in agreement with the markings used in the linked...

  • Ex-situ XRD (X-ray Diffraction) results for electrodes under different charge/discharge states

    Dane Badawcze
    open access

    Ex-situ XRD was employed to analyze the energy storage mechanism of CPMD in ZICs system. The ZICs were firstly charged to 1.8 V from the open circuit voltage (at around 1.3 V), then discharge to 1.0 V and 0.2 V, and finally recharged to 1.0 V and 1.8 V. Sample abbreviations (CPMD) are in agreement with the markings used in the linked publication.